background image

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

GAS PASTA COOKERS 

ELECTRIC PASTA COOKERS 

SERIES 90

 

 

 
 
 
 
 

 
 
 
 
 
 
 

 

 

INSTALLATION, USE 
AND MAINTENANCE 

295.3011
295.3051
296.310
296.305

GB

Summary of Contents for 295.3011

Page 1: ...GAS PASTA COOKERS ELECTRIC PASTA COOKERS SERIES 90 INSTALLATION USE AND MAINTENANCE 295 3011 295 3051 296 310 296 305 GB ...

Page 2: ...Water emptying Wasser entleeren Fig Abb 1 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse 2953051 G Gas Gaz C Carico acqua Remplissage d eau Water filling Wasser anfüllen S Scarico acqua Évacuer l eau Water emptying Wasser entleeren Fig Abb 2 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse ...

Page 3: ...Water emptying Wasser entleeren Fig Abb 3 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse 296305 E elettrico électrique electric Elektrisch C Carico acqua Remplissage d eau Water filling Wasser anfüllen S Scarico acqua Évacuer l eau Water emptying Wasser entleeren Fig Abb 4 Dimensioni Dimensions Floor space dimensions Raumbedarfsmasse ...

Page 4: ...Forberedt til brug af gas Za ízení na plyn Toimib gaasi põhjal A berendezés gáz használatára elõkészített Sagatavota darbam ar g z Przysposobione na gas Numatyta dumjos Nastavený na plyn Pripravljeno za plin G20 20mbar H CAT KAT GAS GAZ G30 G31 G20 G25 G25 1 G110 G120 Made in E U I2H p mbar 20 LV I3P p mbar 37 IS I3B P p mbar 28 30 28 30 CY MT II2E 3P p mbar 37 20 25 LU II2E 3 p mbar 28 30 37 20 2...

Page 5: ...igg Abb 12 Sostituzione ugello bruciatore Regolazione dell aria primaria Changement du gicleur du brûleur Réglage de l air primaire Substituting the burner nozzle Regulating the primary air Austausch der Hauptbrennerdüse Primärluftregelung des Hauptbrenners Figg Abb 13 14 Sostituzione del By Pass Changement du by pass Substituting the By Pass Austausch des By Pass Fig Abb 15 Sostituzione dell ugel...

Page 6: ...udelkocher Fig Abb 18 Carico vasca Remplissage de la marmite Filling the tub Anfüllen des Beckens Fig Abb 19 Scarico vasca Vidage de la marmite Emptying the tub Entleeren des Beckens Fig Abb 20 Sostituzione delle resistenze elettriche Remplacement de résistances électriques Replacement of the heating elements Ersetzen der elektrischen Widerstände des elektrischen Fig Abb 21 Sostituzione componenti...

Page 7: ... 1 088 1 460 3 561 27 6 UNI ISO 7 1 R 300 UNI ISO 7 1 R 2953051 Gas pasta cooker 1 module 900x900x900 27 6 A1 B11 2 177 2 921 7 123 55 2 UNI ISO 7 1 R 300 UNI ISO 7 1 R 296310 Electric pasta cooker module 450x900x900 10 230 3 400 3N 50 4x4 5 x 1 5 300 UNI ISO 7 1 R 296305 Electric pasta cooker 1 module 900x900x900 20 230 3 400 3N 50 4x10 5 x 4 300 UNI ISO 7 1 R Gas type Nominal capacity kW Reduced...

Page 8: ...tion x mm GAS PASTA COOKERS BURNER module Liquid gas LPG G30 G31 13 80 3 00 190 75 30 Open Natural Methane gas G20 13 80 3 00 280 125 51 3 0 Town gas G110 13 80 3 00 600 Reg 75 Open Town gas G120 13 80 3 00 550 Reg 75 Open GAS PASTA COOKERS BURNER 1 module Liquid gas LPG G30 G31 13 80 x 2 3 00 x 2 190 x 2 75 x 2 30 x 2 Open Natural Methane gas G20 13 80 x 2 3 00 x 2 280 x 2 125 x 2 51 x 2 3 0 Town...

Page 9: ...y kW Reduced capacity kW Diameter of main injectors 1 100 mm By Pass diameter 1 100 mm Pilot injectors N Air regulation x mm GAS PASTA COOKERS BURNER module Natural Methane gas G20 13 80 3 00 280 125 51 3 0 GAS PASTA COOKERS BURNER 1 module Natural Methane gas G20 13 80 x 2 3 00 x 2 280 x 2 125 x 2 51 x 2 3 0 Table 8 BURNER FEATURES PL CAT II2E3P Gas type Nominal capacity kW Reduced capacity kW Di...

Page 10: ... be handed over The user must be informed that any building modification or restructuring that may in any way modify the air supply necessary for combustion makes it necessary to carry out another check of the functionality of the appliance TECHNICAL FEATURES The following instructions for starting up and functioning refer to gas and mixed appliances belonging to category I3B P II2H3 II2H3B P II2L...

Page 11: ...eating is done by means of elements protected with a sheath resistant to salted water PROVISIONS FOR INSTALLATION Place fig 6 pag 4 It is advisable to install the appliance in a well ventilated room or under an extractor hood The appliance may be installed as a single unit or together with others In both cases if it is installed near a wall of inflammable material a minimum distance of 150mm from ...

Page 12: ...ducts of combustion directly into external environment The energy supply to the appliance must be controlled by the system of forced evacuation and must be interrupted in the event that its capacity falls below the values prescribed by the norms in force It must only be possible to restart the gas supply manually Forced evacuation under hood fig 9 pag 4 In this case the fumes evacuation device of ...

Page 13: ... panel of the top Furthermore the efficiency of the earth connection must be checked and also that the earth conductor on the connecting side is longer than the other conductors and that the connecting cable has a wire bunch adequate for the power absorbed by the appliance and is at least type H05 RN F In accordance with international rules before installing the appliance a unipolar device must be...

Page 14: ...eading is not within the limits of the table find out the cause After solving the problem check the pressure again Checking the power Normally it is sufficient to check that the nozzles installed are the right ones and that the burners function properly If desired further check the power absorbed by using the Volumetric Method With the help of a chronometer and a counter it is possible to read the...

Page 15: ...urner nozzle fig 12 pag 5 To substitute the burner nozzle it is necessary to open the door of the compartment After doing this the screw which blocks the regulation of primary air must be loosened 1 and regulated until completely open 2 the nozzle must be unscrewed 3 with a spanner and substituted with an appropriate nozzle for the type of gas used shown in tables 2 8 pag 7 9 This nozzle must be a...

Page 16: ...that the heating elements are on It is advisable to regulate the element to the maximum temperature in order to reach the desired temperature right away and to leave it in this position for a few minutes then turn the knob into the position desired To turn off the pasta cooker turn the knob back into position 0 Position N Use 0 Pasta cooker off 1 Maintaining temperature 2 Cooking 3 Starting cookin...

Page 17: ...ive synthetic sponge or stainless steel wool would be preferable to be used in the direction of the grain After washing dry with a soft cloth If the appliance is out of use for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply and wipe all stainless steel surfaces with a cloth soaked in vaseline oil in order to give it a protective film and air the roo...

Page 18: ... Remove the protector 1 from the elements by loosening the fixing screws 2 unscrew the fixing screws 3 of the element to be substituted and after disconnecting remove it Electric components of the electric pasta cooker fig 21 pag 6 For the replacement of the selector 5 of the contactor 4 of the lamp and of the main terminal board 2 of the electric pasta cooker it is necessary to unscrew the fixing...

Reviews: