We welcome our customers suggestions on how to speed up these efforts.

Hazardous Substance Statement

 

 

 

 

 

 

Warranty

The 

 

warranty 

 

period 

 

for 

 

PHscan 

 

series 

 

tester 

 

is 12 months from the date of

shipment.

 

Above

 

warranty

 

does

 

not

 

cover

 

pH

 

electrode

 

module

 

and

 

calibration

 

solutions.

 

For more information,

 

please contact nearest authorized distributor.

BANTE INSTRUMENTS LIMITED
E-mail: [email protected]
Phone: 0086-21-6404-1598
Website: www.bante-china.com

The information in this document is subject to change without notice.
Copyright © Bante Instruments Limited, 2013. All rights reserved.

PHscan40BNC Pocket pH Tester

Instruction Manual

Technology to create the future...

BANTE INSTRUMENTS LIMITED

Summary of Contents for PHscan40BNC

Page 1: ...me our customers suggestions on how to speed up these efforts Hazardous Substance Statement Warranty The warranty period for PHscan series tester is 12 months from the date of shipment Above warranty...

Page 2: ...Indicates tester is in the measurement mode Indicates tester is in the calibration mode Indicates tester is in SETUP mode Indicates the measured value has been frozen Indicates temperature compensati...

Page 3: ...etically sealed glass containers Press and hold the MEAS key for 5 seconds the tester will turn off If you do not press any key for 8 minutes the tester will automatically turn off to conserve energy...

Page 4: ...nter Cal Enter Cal Press ENTER key to confirm the tester goes to temperature setting mode o the display shows C CAL If you do not want to modify current temperature value press ENTER key the tester wi...

Page 5: ...splay shows the C CAL or F CAL 4 Press CAL key to enter the temperature setting mode o 5 Press CAL key again to set temperature value Displayed value 0 5 C 6 Press ENTER key to confirm the display sho...

Page 6: ...with distilled water ait for the measured value to stabilize the display shows electrode slope and END Second point calibration is done 3 Points Calibration Make sure that you have selected 3 points...

Page 7: ...ain to release the measured reading you can continue to take measurement Electrode Care and Maintenance the tester immediately freezes current displayed value Hold Meas PHscan40 PHscan40 11 12 Clogged...

Page 8: ...ht 100 grams 185 L 40 Dia mm Incorrect buffer used or contaminated buffer solution Use fresh pH buffer solutions for calibration Electrode is broken Replace the electrode module Keypad is not working...