[Function of Head part]

A base head supplies power 24VDC/max.2A to a remote head  without physical 

contact. A base head and a remote head transmit input/output signals each 

other.

Outline of Remote System

Remote System is designed to operate many detector switches and 

actuators by supplying power and transmitting bi-directional signals.

Construction of the system

Specifiaction

Measurment

75

75

30

90

90

30

45

phi 5.5 phi 10 

depth 6

Base 

Amplifier

Base Head

Remote Head

Remote Amplifier

Remote head

Base head

Type Number

RCH08T-211-PU_ _ RCH08E-211-PU_ _

Applicable

amplifier

*

Output8

RC08T-011N(P)-000 RC08E-011N(P)-000

RC08EA-011N(P)-000


Output32

RL64T-344N(P)-000 RL64E-333N(P)-000

RL64EA-355DN-000

RL64T-345N(P)-000 RL64E-366CL-000

RL64E-366EI-000

Operating distance

4 ... 9 mm / refer to the table below

Driving current

1 A ... 2 A / refer to the table

Driving voltage

24 V DC+/-1.5V

Supply voltage

24 V DC +- 5%

Current consumption

=< 4 A

Operating temprature

0...+50 deg.C.

Protection class

IP 67

Material Case

AAlumite-treated

Operating Surface ABS+PBT

Cable

Phi 7.8  2 x 1.25mm

2

  + 2 x 0.2mm

2  

+ Shield/ PUR 

RCH08E-211-PU-__
RCH08T-211-PU-__

The minimum bending radius for the 

sensors are 50mm.

Remote System

User’s Guide

Attention for Installation

(Read this section thoroughly before installation.)

Before using the Remote Sensor, read this manual carefully. 

During installation and operation, pay close attention to the safety aspect.

Ensure the power is switched off during installation or maintenance operations. 

Use a regulated power supply, e.g. switch-model type.

    Simpler power supplies, such as a full-wave rectification type,

    will cause the permissible ripple rating to be exceed and may

    cause malfunction.

Ensure correct connections by reference to the wiring diagram.

To avoid malfunction caused by induction noise, cable should

     be kept apart from motor or other power cable.

Please do not face the output sensor to a metal at all times to avoid metal 

  overheating or damage of the components.

◆ 

When the unit keeps to be using under out-of-specification distance/center offset 

     /overload status for long time, it may be damaged by overheating.

(Former NIHON BALLUFF co., Ltd.)

Remote Coupler Sytem

Base head / Remote head

 

Base head       : RCH08E-211-PU_ _

Remote head   : RCH08T-211-PU_ _

Install

in order to avoid influence of surrounding metal and 

mutual intererance,  

keep minimum spacing as described below.

1) The cable length between a Head and a Amplifier may not be longer than 10m/

    Base head and Base amplifier and 5m/Remote head and Remote amplifier.

2) The cable shield must be grounded.
3) 

The 0V & the shield must be connected on Amplifier side.

Surrounding Metal

Mutual intererance

Type code

A

B

C

D

RCH08□-... 

50

45

45

300

[Supply voltage : 24V DC]

14 

12 

10 

  -15   -10   -5    0      5    10    15 

Drive current

1A

Drive current

2A

Transmitting Diagram

Wiring to Amplifier

【 

Base part

 】

【 

Remote part

 】

Wrong signal could be output when operating  

    distance or center offset is out of specification 

     range.

Operating distance

4 ... 9mm 6 ... 8mm

Center offset max.

±5mm

±3mm

Driving current

1A

2A

X:Center offset
Y:Operating

 

distance

Y

X

(mm)

< Note >

Ta k e  m e a s u r e s  s o  t h a t 

ambient temperature is not 

over 50 degrees Celsius, for 

RCH08 produces fever.

A

B

C

D

Remote Head

RCH08T-…

Base Head

RCH08E-…

Remote Head

RCH08T-…

Base Head

RCH08E-…

Remote Amplifier

RC08T-…

Base Amplifier

RC08E-…

Remote 

Amplifier

RL64T-…

Base Amplifier

RL64E-…

Brown

Brown

Brown

Brown

max.5m

1)

max.10m

1)

FG

2)

FG

2)

FG

2)

max.10m

1)

*  There is no terminal box of a shield in RL64E-333… . 

   After connecting a blue (0V)  and shielded cable, 

  it connects with FG. 

max.5m

1)

+V

+24V

+24V

+V

White

White

White

White

SI

SI

SI

SI

Black

Black

Black

Black

SO

SO

SO

SO

Blue

Blue

Blue

Blue

0V

0V

0V
Shield

*

0V

Shield

3

Shield

3

Shield

3

Shield

3