background image

Oil-Free Range Operators Handbook
VT,  VTS & VTH models

Covering Models:-

BAMBI AIR LTD

152 Thimble Mill Lane

Heartlands

Birmingham

B7 5HT

Tel:  0121 322 2299

Fax: 0121 322 2297

Email: [email protected]

www.bambi-air.co.uk

VT75 / VT150 / VT200 / VT250 / VT300 / VT400

VT75D / VT150D / VT200D / VT250D / VT300D / VT400D

VTS75 / VTS150 / VTS200 / VTS250

VTS75D  / VTS150D / VTS200D / VTS250D

VTH75 / VTH150 / VTH200

VTH75D / VTH150D / VTH200D  

C

M

Y

CM

MY

CY

CMY

K

VT HandbookA5 Iss 6 0517 PRINT BnC.PDF   1   18/03/2019   13:07

Summary of Contents for VT

Page 1: ...l Lane Heartlands Birmingham B7 5HT Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk VT75 VT150 VT200 VT250 VT300 VT400 VT75D VT150D VT200D VT250D VT300D VT400D VTS7...

Page 2: ...mechanical or personnel hazards and will invalidate your warranty Bambi reserves the right to modify the contents of this operating booklet without notice and the information is in no way binding on t...

Page 3: ...he compressor Site in a dry area avoiding damp or humid conditions The site must be dust free well ventilated and have a cool ambient temperature 40 C should be regarded as the maximum allowable ambie...

Page 4: ...ill need to fit before use Attach the condensate bottle mounting bracket to the front panel of the compressor using the 2 plastic clips provided These are a simple push fit Slide the condensate bottle...

Page 5: ...re fitted with a sequential start system to reduce electrical loading You will notice one motor starting a few seconds after the other single phase only This is normal As air is used the pressure drop...

Page 6: ...until an audible click is heard Retighten without using excessive force Fig 6 Pressure relief valve positions 6 Operation Dryer Models When equipped with an air dryer unit the compressor will automati...

Page 7: ...l activate To re set follow the procedure below Models VT H 75 75D VT H 150 150D VT H 200 200D VT250 250D Switch off at the pressure switch see Fig 2 Allow 50 minutes for the motor to cool down then s...

Page 8: ...in place and remove the end covers Remove the bolts holding the top cover in place Gently lift up the top housing Note Do not use excessive force as this will strain the electrical and air connections...

Page 9: ...0 240 380 415 Frequency Hz 50 Amps Single phase 3 phase 6 8 2 9 Displacement l min 175 VT 2 0Hp Pump Specification Motor kW Hp 1 5 2 0 Voltage Single phase 3 phase 220 240 380 415 Frequency Hz 50 Amps...

Page 10: ...x 10mm tube elbow BPB0277 11 Red nylon drain tube BPB0284 12 50mm tank pressure gauge BPB0658 13 Pressure switch BPB0550 14 40mm line pressure gauge BPB0657 15 Pressure regulator BPB0510 16 18 Safety...

Page 11: ...ubber mounting BPB1296 10 Drain valve tap BPB0895 11 3 8 x 10mm tube elbow BPB0276 12 Red nylon drain tube BPB0284 13 50mm tank pressure gauge BPB1081 14 Pressure switch BPB0550 15 40mm line pressure...

Page 12: ...26 27 28 29 30 31 32 33 34 35 36 37 38 2 15 41 39 40 30 10 15 15 15 41 13 15 15 4 18 43 42 41 Push fit Reducer 10mm Male 6mm female BPB1338 Ref No Description Part No 1 1 4BSP Condensate Diffuser BPB1...

Page 13: ...31 33 34 35 24 2 10 26 25 36 40 39 37 6 13 14 11 32 3 12 10 14 17 40 10 32 18 38 14 20 16 19 41 42 21 43 47 Push fit Reducer 10mm Male 6mm female BPB1338 4 Ref No Description Part No 1 1 4BSP Condensa...

Page 14: ...tube elbow VT200 BPB0280 10b 3 8 x 10mm tube elbow VT150 BPB0277 11 Drain tube BPB0284 12 50mm tank pressure gauge BPB0658 13 Pressure switch BPB0550 14 40mm line pressure gauge BPB0657 15 Pressure re...

Page 15: ...96 9 3 8 x 1 4 Reducing bush BPB0356 10 1 4 drain tap BPB0895 11 1 4 x 10mm tube elbow BPB0276 13 12 Drain tube BPB0284 13 50mm tank pressure gauge BPB1081 14 Pressure switch BPB0550 15 40mm line pres...

Page 16: ...ipe BPB0508 39 Purge tank bleed valve BPB0775 40 Purge tank BPB0484 41 10mm Nylon tube BPB0551 42 Push fit Reducer 10mm Male 6mm Female BPB1338 42 Ref No Description Part No 1 1 4BSP Condensate Diffus...

Page 17: ...return valve BPB0656 17 Adaptor BPB0356 18 Extension BPB0152 19 30mm Rubber mounting BPB1296 43 Push fit Reducer 10mm Male 6mm Female BPB1338 44 Ref No Description Part No 1 1 4BSP Condensate Diffuse...

Page 18: ...plug seal BPB0502 23 Hex screw BPB0265 24 1 4 Tee BPB1109 25 M6 x 25 washer BPB0121 26 M8 nut BPB0161 27 1 4 x 10mm Elbow BPB0276 28 Reducing bush BPB0255 29 1 4 x 6mm Tube swivel elbow BPB0042 30 6mm...

Page 19: ...17 1 5 7 8 13 14 15 16 17 15 18 19 20 21 24 25 26 27 28 30 31 32 33 34 36 2 4 23 22 35 38 29 39 37 6 11 12 10 29 40 3 45 42 43 41 41a 44 46 29 47 46 48 49 50 9...

Page 20: ...8 x 10mm Tube connector BPB0275 VTS75D 150D 200D 18 29 3 8 Non return valve BPB0822 30 3 8 Plated elbow BPB0282 31 Safety valve BPB1084 32 Pressure switch BPB0550 33 Delivery pipe BPB0508 34 1 4 Tee...

Page 21: ...xplo to go in 1 5 5 5 8 9 12 13 14 15 11 16 17 18 19 20 11 10 23 24 26 27 3 28 29 30 2 4 22 21 30 32 33 34 31 6 10 11 11 25 11 3 35 38 39 40 37 42 42a 43 43a 44 37 46 45 48 17 37 47 41 49 50 51 52 55...

Page 22: ...tube fitting BPB0044 11 3 8 X 3 8 N R valve BPB0656 12 Pressure gauge BPB1081 13 3 8 Tee BPB0802 14 Safety valve BPB1084 15 1 4 Elbow BPB1139 16 Pressure switch BPB0550 17 1 4 x 1 4 Adaptor BPB1078 1...

Page 23: ...81 21 Safety valve BPB1084 22 1 4 Elbow BPB1139 23 Pressure gauge BPB0657 24 Pressure switch BPB0550 25 3 8 x 3 8 Adaptor BPB0283 26 On Off valve BPB1079 27 Regulator BPB0510 28 Base plate BPB0315 29...

Page 24: ...B0517 21 20mm Rubber mount BPB0273 22 M8 Flanged nut BPB0130 23 40mm Rubber mount BPB0272 24 Cabinet LH panel BPB0351 25 1 8 x 6mm Elbow BPB0278 26 Delivery pipe BPB0508 27 3 8 x 10mm Tube elbow BPB02...

Page 25: ...23 1 5 7 8 5 9 13 14 15 16 17 18 19 20 21 22 24 25 26 27 28 30 31 32 33 34 36 2 4 23 25 35 37 38 39 19 6 10 10 12 11 29 40 3 42 43 44 41 45 5 46 47 53 11...

Page 26: ...l Coalescing BPB1359 26a 1 4bsp x 1 8bsp Reducing Bush BPB0041 27 Element for BPB1359 BPB1367 28 Delivery pipe BPB0508 29 3 8 Bulkhead connector BPB0749 30 3 8 Elbow BPB0629 31 Twin tower dryer BPB083...

Page 27: ...7 8 9 10 15 16 17 18 19 20 21 22 23 24 27 28 29 30 31 33 34 35 36 37 39 2 4 25 38 41 42 43 40 6 11 13 14 12 32 44 3 46 47 48 45 49 51 9 8 8 8 21 26 26 26 25 22 25 29 23 21 53 54 55 52 56 57 48 48 50...

Page 28: ...BPB0281 16 Solenoid c w cable BPB0545 17 1 8 x 6mm Push fitting BPB0154 18 Crankcase mounting bracket VT300 BPB0347 18a Crankcase mounting bracket VT400 BPB0517 19 20mm Rubber mounting BPB0273 20 40mm...

Page 29: ...r Centrifugal Coalescing BPB1359 25a Coalescing filter auto drain BPB1336 26 Element for BPB1359 BPB1367 27 1 4 x 3 8 Adaptor BPB0591 28 Dryer mounting clamp BPB0503 29 Purge tank BPB0484 30 Purge tan...

Page 30: ...itor VT150 BPB0696 34 Motor fan cover BPB0618 30a 30b 1a 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 23 24 25a 25b 26 27 28 29 4 5 10 31 21 35 Terminal box for VT pumps BPB1329 32 22 1b Ref No Descr...

Page 31: ...over BPB0716 36 Motor fan cover BPB0619 10 1b 2 3 4 5 6 7 8 9 12 13 14 15 16 17 18 19 20 21 22 23 25 26 27 28 29 30 31 32 4 11 5 33 1a 24 34 37 Terminal box for VT pumps BPB1329 Ref No Description Par...

Page 32: ...onnecting pipe nut BPB0986 46 Connecting pipe olive BPB0985 3 5 6 7 8 13 14 15 16 17 18 19 20 21 24 25 26 27 28 30 31 32 33 34 36 1a 23 22 35 38 39 40 37 4 9 11 12 10 29 41 2 43 42 1b 5 14 4 Ref No De...

Page 33: ...R Wiring Diagrams SINGLE PHASE K Live Neutral Earth KKEY 31 A1 15 18 A2 DO NOT ALTER VT300 400 300D 400D Electrics enclosure Motor 1 Fan 1 Solenoid 1 Fan 2 Solenoid 2 Motor 2 Supply 1 5 To electrics e...

Page 34: ...Solenoid 10 Compressor 11 Cooling fan 12 Power in 12 11 8 7 6 5 4 3 9 2 1 10 1 Thermal fan switch 2 Pressure switch 3 Exhaust fan 4 Thermal trip 5 6 7 8 Connection blocks 9 Solenoid 10 Compressor 11 C...

Page 35: ...Thermal trip 5 6 7 8 14 15 Connection blocks 9 Solenoid 10 Motor 11 Aftercooler fan 12 Thermal fan switch 13 Timer box Note Timer box only used on Dryer models NOTE The cooling fans remain live even w...

Page 36: ...TOR 2 N GREY BLUE EARTH BROWN BLACK Solenoid 1 Solenoid 2 Fan 1 Fan 2 Overload set to 10 amps DO NOT ALTER NOTE Fans only used on dryer models L1 L2 L3 SUPPLY VT300 400 300D 400D PRESSURE SWITCH MOTOR...

Page 37: ...re Company 35 BPVT 1 Service Kit covers models VT75 VT150 VT250 2 kits VT300 2 kits including H D S variants BPVT2 Service Kit covers models VT200 and VT400 2 kits including H D S variants BPB0655 req...

Page 38: ...10 Class 9 2 9 Molecular Sieve Type BS4A 2 5 5 00mm Test Result 40 Degree Dew Point Duty Cycle Time Full Flow 50 Performance 100 pass NOTE To ensure the optimum performance of your Bambi dryer please...

Page 39: ...37 NOTES...

Page 40: ...H SERVICE KIT L Clutterbuck Director BAMBI AIR LTD 152 Thimble Mill Lane Heartlands Birmingham West Midlands B7 5HT Tel 0121 322 2299 Fax 0121 322 2297 e mail EC Declaration of Conformity Declaration...

Reviews: