Page 1: ...UM 020 Bugbox M User Manual Affix Serial Number Sticker Here...

Page 2: ...s very affordable and maintenance costs are the lowest in the product class Features and Benefits Compact size Your personal workstation Quick and easy direct access with the gloveless cuffed Ezee Sle...

Page 3: ...upply requirements 10 Voltage and frequency requirements 10 Power consumption 10 Powering the workstation 11 Workstation overview 12 Workstation layout 12 Component layout 12 Front view 12 Rear view 1...

Page 4: ...Ezee Sleeves 23 Exiting the workstation chamber using the Ezee Sleeves 24 Arm gas displacement volume and pressure changes 24 Single Plate Entry System SPES 25 SPES overview 25 Using the SPES 26 Inter...

Page 5: ...mains fuses 38 Service requirements 39 Spare parts and accessories 39 Overview 39 Spare parts and cleaning agents 39 Accessories 40 Workstation malfunction 41 Common problems and solutions 42 Worksta...

Page 6: ...ator should be used for a bottled gas supply The maximum supply pressure permissible is 4 bar gauge The maximum permissible concentration of Hydrogen in the anaerobic mixed gas is 5 5 Hydrogen The mai...

Page 7: ...the symbols found on the Bugbox M Figure 1 Bugbox M symbols Symbol Meaning Refer to user manual Alternating current O Off I On Primary earth connection This product complies with the essential EEA re...

Page 8: ...osed of at a household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Date of manufacture in format YYYY MM Installa...

Page 9: ...60 mm Workstation chamber internal width 500 mm Workstation chamber internal height 420 mm Workstation chamber internal depth 460 mm Interlock internal width 100 mm Interlock internal height 200 mm In...

Page 10: ...ge internal components of the workstation and will invalidate the warranty Electrical supply requirements The workstation must be connected to a mains power supply A power cord is supplied to connect...

Page 11: ...re 12 To switch the workstation off press the power switch item 2 in Figure 12 Note A glove port should be left open when the workstation is switched off as the pressure inside the workstation will de...

Page 12: ...love ports and the interlock The interlock consists of the interlock chamber with an inner and an outer door The Bugbox M workstation is controlled via the control panel Component layout Please famili...

Page 13: ...Bugbox M UM 20 R4 0 Page 13 of 47 Bugbox M User Manual Rear view Figure 5 shows the rear view of the Bugbox M workstation Figure 5 Bugbox M workstation rear view...

Page 14: ...ugbox M workstation left side view 1 Pressure relief tank cover pressure relief tank bung 2 Pressure relief tank 3 Pressure relief tank cover 4 Pressure relief tank overflow pipe 5 Vacuum port optiona...

Page 15: ...ure 7 shows the right side view of the Bugbox M workstation Figure 7 Bugbox M right side view 1 Interlock outer door knob 2 Interlock outer door 3 Power entry panel 4 Serial number label 5 PAT test la...

Page 16: ...on 2 Chamber light switch 3 Gas Alarm switch Press to switch the gas alarm on off 4 Humidistat Controls the level of humidity inside the workstation chamber 5 Lock active indicator LED Flashes to ind...

Page 17: ...ure 0 1 C increments or humidity 5 Increase temperature 0 1 C increments or humidity For temperature control the white value PV Process Value is the actual temperature The green value SV Set Value is...

Page 18: ...rge control Figure 11 Foot switch control panel 1 VAC for glove port vacuum control 2 LOCK for interlock purge control 3 SPOT for spotlight operation Power entry panel Figure 12 shows the power entry...

Page 19: ...nnot be added after manufacture of the workstation Note Any equipment installed in the workstation chamber must be compatible with the humidity level inside the workstation chamber If in doubt consult...

Page 20: ...To close the interlock outer door push the interlock outer door down The door latch will click to indicate that the door is closed Note Do not open the interlock outer door if the interlock inner door...

Page 21: ...Ezee Sleeves see section 6 2 2 for more details Open the interlock inner door see section 6 1 3 for more details Remove the Petri dish holder from the interlock Close the interlock inner door see sect...

Page 22: ...to the workstation chamber via the SPES and unloading the interlock Right hand glove port only for unloading the interlock For each method of entry the glove port selector knob Figure 10 must be set i...

Page 23: ...Ezee Sleeves Repeat the procedure for the other hand if both hands are to enter the workstation chamber Press and hold the vacuum pedal with your foot item 1 in Figure 11 until the internal gas volum...

Page 24: ...ort bar inside the glove port so that it is vertical Tighten the glove port cover knob Do not over tighten the glove port cover knob Supporting the Ezee Sleeve cuff with your opposite hand pull your h...

Page 25: ...also known as the mailbox SPES overview The SPES consists of an external hinged flap and an internal hinged flap The external flap is held in place by a thumb screw when not in use The internal flap i...

Page 26: ...Push materials through the SPES internal flap into the workstation chamber This should be done as quickly as possible to minimise gas loss from the workstation chamber When all materials have been add...

Page 27: ...after each use Rear shelf The Bugbox M workstation has a rear shelf for additional storage within the workstation chamber The weight limit for the shelf is 5 5kg The weight on the shelf must be evenly...

Page 28: ...nd Turn the grey collar anti clockwise counter clockwise to loosen the cable gland Remove the red plug Push the cable through the cable gland Tighten the grey collar by turning clockwise until tight D...

Page 29: ...m Petri dishes The vacuum port is located on the left hand side of the workstation item 3 in Figure 6 To use the vacuum port Connect the vacuum source to the external part of the vacuum port by pushin...

Page 30: ...UM 20 R4 0 Page 30 of 47 Bugbox M User Manual Online video user guides Further information and demonstrations can be found at Ruskinn Technology Limited s YouTube channel http www youtube com ruskinnt...

Page 31: ...or Tristel Duo Foamer Tristel Fuse Sachets and Duo Foamer are available from Ruskinn Technology Limited see section 7 4 2 for details Ruskinn Technology Limited anti static cleaner Distilled water No...

Page 32: ...terlock inner door o The glove port covers o The inside of the SPES For all workstation components wipe with a paper towel soaked in an appropriate cleaning agent Take care not to get cleaning agents...

Page 33: ...mation Either open the SPES see section 0 or open one of the glove port covers see section 6 2 2 to equalise the pressure between the workstation chamber and the external environment Remove the pressu...

Page 34: ...ws the O ring removal Figure 25 O ring removal Remove the Ezee Sleeve To install an Ezee Sleeve Place the new Ezee Sleeve onto the glove port ensuring that the O ring grooves are completely covered an...

Page 35: ...leeves see section 7 2 2 for more information Undo the glove port covers and place on the rear shelf Lift the floor tray at the front to expose the detox sachets Figure 26 shows the location of the sa...

Page 36: ...facility Return the ICO2N2IC to the main menu Switch off Bugbox M and disconnect from the mains power supply Remove the Ezee Sleeves see section 7 2 2 for more information Undo the glove port covers...

Page 37: ...s power supply Remove the plug from the mains socket Using a small flat bladed screw driver remove the fuse cover from the mains plug Figure 27 shows the fuse removal Figure 27 Mains plug fuse removal...

Page 38: ...val of the mains fuse holder Figure 28 Mains fuse holder removal Replace the mains fuses The fuse ratings are o 240V 50Hz F3 15A H250V o 220V 60Hz F3 15A H250V o 110V 60Hz F5A H250V o 100V 50 60Hz F5A...

Page 39: ...the biennial service includes an annual service Note The annual service includes the replacement of the detox and the catalyst sachet Service contracts are available for all Ruskinn Technology Limited...

Page 40: ...gbox M workstation Figure 31 is the list of accessories for the Bugbox M workstation Please contact your local distributor for the latest pricing and availability Figure 31 Bugbox M accessories Item D...

Page 41: ...lease contact your local distributor quoting the serial number of your workstation If the problem is related to the ICO2N2IC please download the event log to a USB device see UM 011 ICO2N2IC user manu...

Page 42: ...fuse has blown Contact your local distributor Devices plugged into the internal socket are not powering up The power switch on the device is not switched on The plug for the device is not fully insert...

Page 43: ...he workstation chamber In normal operation the gas demand indicator should not illuminate more than once every 20 minutes when the workstation is at rest At rest is defined as the gasses are within de...

Page 44: ...details Contact your local distributor The gas mixer alarm is sounding A gas cylinder is empty Check the ICO2N2IC gas mixer screen to see which gas cylinder is empty An empty cylinder will be indicat...

Page 45: ...F FITNESS FOR A PARTICULAR PURPOSE THE IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE CUSTOM OR USAGE OF TRADE Ruskinn Technology Limi...

Page 46: ...be disposed of at a household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Alternatively please contact your local...