Interface Module XC 

 

Protocol Converter / User Manual

 

Page 1 from 12 

E130506819092 

Baer Energie- & Messtechnik GmbH 

 Siemensstr. 3 

 D-90766 Fürth 

 Phone +49 911 970590 

 Fax +49 911 9705950 

 

 

General 

The 

Interface  Module  XC

 

  is  designed  for  use  with  the  EMH  LZQJ-XC  and  DMTZ-XC 

meters.

 

The  module  is  equipped  with  an  M-Bus  (2  wires)  interface.  The  module  can  be  plugged 

easily into the module compartment of the meter. It can be mounted or exchanged during operation 
(without  breaking  approval  seal).  An  integrated  M-Bus  interface  (Protocol  Converter  to  DIN  EN 
13757-3)  provides  a  simple  means  of  connecting  multi-energy  meters.  This  makes  multi-energy 
applications an affordable proposition for domestic use.  Due to the communication, the modules are 
suitable for a lot of control centres.

 

 

 

Compatible meters 

 

LZQJ-XC (special meter for industrial applications): 
- Standard meter for direct connection  
- Transformer connection version Cl. B (Cl. 1) 
- Precision meter Cl. C (Cl. 0.5S) 
- Precision meter Cl. 0,2S 

 

DMTZ-XC (residential meter)  

Functions 

 

M-Bus interface (2 wires, passive) for bi-directional 
communications; 
Alternative:  BFC-Bus (BAER Field Control, 56VDC); 

 

Transmission protocol: M-Bus (DIN EN 13757-3:2013-08); 

 

Internal communication interface for the transfer data 
between the meter and the interface module (service data 
list / table TS); 

 

Protocol converter for meter data into M-Bus-Format 
(non transparent data readout); 

 

Internal power supply from meter; 

 

Exchangeable during the meter operation;  

Safety Notes 

 

 

The owner of the interface modules is responsible that all persons engaged on 
work with the modules: 
•  Are competent and qualified in accordance with national regulations (see ISSA 

"Guideline for Assessing the Competence of Electrically Skilled Persons").  

•  Have read and understood the relevant sections of the user manual.  
•  Strictly observe the safety regulations (according to the following section) and 

the instructions in the individual chapters.  

The owner of the modules is also responsible for:  
•  The protection of persons.  
•  The prevention of material damage.  
•  The training of personnel. 

The following safety regulations must be observed at all times:  
•  Devices which have fallen down should not be installed, even if no damage is apparent, and should 

be returned for testing to an authorised service centre (internal damage possible).  

• 

Modules must never be cleaned with running water or high pressure devices. Water can cause 

short-circuits or damage el. components.

 

Summary of Contents for Interface Module XC

Page 1: ...ntrol 56VDC Transmission protocol M Bus DIN EN 13757 3 2013 08 Internal communication interface for the transfer data between the meter and the interface module service data list table TS Protocol converter for meter data into M Bus Format non transparent data readout Internal power supply from meter Exchangeable during the meter operation Safety Notes The owner of the interface modules is respons...

Page 2: ...rface module in the meter as follows Installation of the interface module 1 Check the interface module 2 Remove the terminal cover 5 3 Open the transparent module cover 1 4 Insert the interface module 3 carefully at the place provided in the meter 2 5 Push the module in to the internal contacts 6 Connect the cable 7 Close the transparent module cover 1 8 Close the terminal cover 5 Removing of the ...

Page 3: ...e meter manufacturer or operators Parameterisation of the meter EMH COMBI TOOL Software At the first read the read all data from the meter via optical IR interface Baud rate The Interface Module XC uses the same baud rate like the communication interface at the meter For setting use please the EMH COMBI TOOL Software Menu Meter Interfaces Electrical interface For correct working set please a fixed...

Page 4: ...e OBIS Register 0 0 0 secondary address and 0 0 1 primary address in the service data list TS In this example we use the identification number 1 OBIS 0 0 1 for M Bus primary address menu Meter Meter ID OBIS Register 0 0 1 e g value 123 00000123 Standards for M Bus addresses Primary address OBIS Register 0 0 1 Identification 1 range 0 to 250 default 1 Secondary address OBIS Register 0 0 0 device nu...

Page 5: ...ress possible range 0 to 250 1 5 t Last average 1 value active power import t tariff 0 8 s stored values 0 99 21 41 61 5 t Last average 1 phase 1 2 3 2 5 t Last average 1 value active power export 22 42 62 5 t Last average 1 phase 1 2 3 3 5 t Last average 1 value reactive power import 23 43 63 5 t Last average 1 phase 1 2 3 4 5 t Last average 1 value reactive power export 24 44 64 5 t Last average...

Page 6: ...er SND_UD CI Field 52Hex for selection the secondary address request via address FDHex Answer E5Hex Acknowledge Master REQ_UD2 Request User Data Class 2 Answer RSP_UD Respond User Data Further specifications The following definitions shall also apply for the selection of a new secondary address SND_UD the manufacturer code 15Hex A8Hex for EMH will be evaluated wildcard FFHex FFHex is possible the ...

Page 7: ...dress 1 SND_NKE Send Link Reset Answer E5 Master 10 40 FE 3E 16 primary address wildcard 254 FEHex Answer E5 Master 10 40 7B BB 16 primary address 123 7BHex Answer E5 Master 10 7B 7B F6 16 REQ_UD2 Request User Data with primary address 123 7BHex Answer 68 0F 0F 68 08 7B 72 87 98 16 04 A8 15 00 02 00 10 00 00 FD 16 empty message Master 10 5B 7B D6 16 REQ_UD2 Request User Data with primary address 1...

Page 8: ...ta Answer 68 EA EA 68 08 7B 72 87 98 16 04 A8 15 00 02 02 00 00 00 04 03 77 15 00 00 C4 05 03 6D 13 00 00 84 10 03 E6 0F 00 00 C4 15 03 A8 0E 00 00 84 20 03 90 05 00 00 C4 25 03 C5 04 00 00 04 FB 82 73 F5 02 00 00 C4 05 FB 82 73 06 02 00 00 84 10 FB 82 73 E5 01 00 00 C4 15 FB 82 73 54 01 00 00 84 20 FB 82 73 0F 01 00 00 C4 25 FB 82 73 B1 00 00 00 04 2B 0C 00 00 00 04 AB FC 01 00 00 00 00 04 AB FC ...

Page 9: ...x D Nominal voltage Internal power supply from LZQJ XC or DMTZ XC meter M Bus load 1 5mA max voltage 56VDC Battery None Installation Exchangeable during the meter operation LED displays 3 LEDs green Power Tx power transmit data via M Bus yellow Rx receive data via M Bus red Error internal communication error Interface M Bus 2 wires passive according to DIN EN 13757 2 Physical Layer Alternative BFC...

Page 10: ...Page 10 from 12 E130506819092 Interface Module XC Protocol Converter User Manual Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 Fürth Phone 49 911 970590 Fax 49 911 9705950 Dimensions ...

Page 11: ...r Manual Page 11 from 12 E130506819092 Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 Fürth Phone 49 911 970590 Fax 49 911 9705950 Terminal assignment Terminal block Terminal Description a M Bus passive or BFC Bus b M Bus passive or BFC Bus ...

Page 12: ...al Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 Fürth Phone 49 911 970590 Fax 49 911 9705950 Subject to change without notice Version 3 05 Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 Fürth Germany Phone 49 0 911 970590 Fax 49 0 911 9705950 Internet www baer gmbh com ...

Reviews: