manualshive.com logo in svg
background image

Brisch number 76103-390 Issue 2 09/08/02

ENGLISH

*76103-390*

Weight Only Scale

FX 110 / FX 120

User Instructions

Содержание FX 110

Страница 1: ...Brisch number 76103 390 Issue 2 09 08 02 ENGLISH 76103 390 Weight Only Scale FX 110 FX 120 User Instructions ...

Страница 2: ...ry Berkel Limited and is supplied without liability for errors and omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied c ...

Страница 3: ...To avoid the possibility of electric shock or damage to the machine always isolate from the mains power supply before carrying out any routine maintenance Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions such as washing soda should not be used especially on the display windows Under no circumstances should you attempt to wipe the inside of the machine The outside of the m...

Страница 4: ... steady and free from vibration and draughts Hold the scale by the base when picking up Do not pick up the scale by the weigh plate or cross Adjust the feet if the scale is not level Remove parts 1 4 before installing the machine Installation FX110 only ...

Страница 5: ...Remove weigh plate FX120 To avoid the risk of RSI Repetitive Strain Injury it is important to ensure that the machine is placed on a surface which is ergonomically satisfactory to the user In cases where usage is prolonged EN614 1 recommends frequent breaks for the user Installation ...

Страница 6: ...2 3 4 Connect power cable To connect remote display Replace the weighplate Connect to power point OR ...

Страница 7: ...ted to the power supply and remove weigh plate Turn over machine and place on a safe level surface Turn the machine round so the required mounting slot is next to the edge of the counter Remove the screw in the mounting slot 1 2 3 4 Slot 1 Slot 2 Slot 3 required mounting slot ...

Страница 8: ...Place the mounting bracket into the slot 5 6 Place washer over screw hole and fix with the large replacement screw ...

Страница 9: ...ages and Place machine upright Do not lift the scale by the column display or the weighplate 9 Replace the weigh plate Connect to power point Caution Plug the display cable into the base Feed the slack cable round the base Secure the cable clips ...

Страница 10: ...Cable route single display Cable from slot 3 Cable from slot 2 Cable from slot 1 1 2 3 4 5 8 9 6 7 1 2 3 4 1 2 3 4 ...

Страница 11: ...Cable route dual display Cable from slot 3 Cable from slot 1 1 2 3 4 1 2 3 4 5 8 9 6 7 ...

Страница 12: ...Cable route dual display Cable from slot 2 Cable from slot 1 1 2 3 4 1 2 3 4 ...

Страница 13: ...Cable route dual display Cable from slot 2 Cable from slot 3 1 2 3 4 5 8 9 6 7 1 5 2 3 4 ...

Страница 14: ...Securing the cable clips ...

Страница 15: ...t circuit thermal characteristics which can adversely affect the performance of the scale When you see the symbol flashing on the display or Battery LED flashing then you must either replace the batteries or recharge the rechargeable battery Caution Using a rechargeable battery pack Recharging the battery pack Note Plug the rechargeable battery pack into the scale and place the pack into the reces...

Страница 16: ...id Prohibited function Prohibited scale capacity Tare weight unsteady Cannot use EPOS tare Mismatch between EPOS and scale tare increments Error codes F 10 F 11 F 30 F 35 F 36 E 120 E 123 E 124 Contact your service agent if you see any other F messeges Tare too heavy Tare already in operation Unit price not accepted Scale has not returned to zero between EPOS transactions E 121 E 122 E 130 E 131 F...

Страница 17: ... scale Depending on configuration Either Displaying service information Resetting the machine Selecting sleep mode Using the scale Testing the display Or LED LCD LCD LED LCD LED Press and hold Press and hold Or T Or ...

Страница 18: ...lace the goods onto the scale Zeroing the scale Make sure that the scale is at zero before weighing any goods Using tares Repeat until all the goods have been weighed Cumulative tare T To cancel a tare T T T Or LCD LED ...

Страница 19: ...ss and hold C Branch Sub branch 12 95 1 Branch 12 For Example Branch 13 Sub branch Sub branch 00 01 Sub branch 98 Value 0 00 19 01 19 00 0 29 00 0 4 C Press and hold C Press and hold Displays the value Press again to re display the branch sub branch After clearing a value to be changed each key press increments the value displayed Pressing and holding the key increments the value by 10 After chang...

Страница 20: ...e Changing the bleeper volume Go to branch 19 Sub branch 04 0 Quiet 1 Loud 19 04 1 0 always off 1 5 seconds 2 1 minute 3 5 minutes 4 always on 20 00 1 Changing the backlight time Go to branch 20 Sub branch 00 0 none 1 1 minute 2 5 minutes 3 30 minutes 20 01 1 Changing the sleep time Go to branch 20 Sub branch 01 0 Off 1 On Switching the bleeper alarm on off Go to branch 19 Sub branch 00 0 Off 1 On...

Страница 21: ...xample 200 2 seconds 150 1 seconds 100 1 second Changing the duration of a Long press press and hold Go to branch 29 Sub branch 00 29 00 200 Enter a value in units of 10 milliseconds 50 255 For example 200 2 seconds 150 1 seconds 100 1 second Enabling key timeout Go to branch 74 Sub branch 01 74 01 1 0 Disabled 1 Enabled ...

Страница 22: ......

Страница 23: ...ified authority Non Automatic Weighing Instruments Directive EMC Directive Low Voltage Directive The applicable harmonised standards are FX 110 Number of EC type approval certificate UK 2625 Manufacturer Avery Berkel Type FX 120 Number of EC type approval certificate T5532 This is a class A product In a domestic environment this product may cause radio interference in whch case the user may be req...

Страница 24: ...Email sales averyberkel com Info averyberkel com Internet http www averyberkel com ...

Отзывы: