background image

Original instruction

INSTRUCTION MANUAL

Blast Chiller Cabinets

Please read the user’s manual before you use this product

Summary of Contents for EBF-03

Page 1: ...Original instruction INSTRUCTION MANUAL Blast Chiller Cabinets Please read the user s manual before you use this product ...

Page 2: ......

Page 3: ...ctly accessing the parameters by selecting the category 10 6 7 Alarms with manual reset 10 6 8 HACCP function 10 6 9 Procedure for setting the default parameter values 11 7 MANITENANCE 11 7 1 PERIODIC CLEANING 11 7 2 CLEANING OF CONDENSER 11 7 3 PERIOD OF INACTIVITY OF CABINET 11 8 TROUBLE SHOOTING AND REMEDIES 12 8 1 If the cabinet does not operate make sure that 12 8 2 If the required temperatur...

Page 4: ...der carpeting runners or the like Arrange cord away from traffic area and where it will not create a tripping hazard Always unplug appliance when not in use and before cleaning adjusting or maintaining this machine To disconnect appliance turn switch off and remove plug from power source Do not disconnect by pulling on the cord Always disconnect by grasping and pulling on the plug top Do not pull ...

Page 5: ...uidelines indicated herein misuse of the refrigerator power supply defects improper or inadequate maintenance unauthorised modification or tampering use of non original spare parts partial or total failure to comply with the instructions All electrical equipment can be hazardous to health Current standards and legal requirements must be complied with during the installation and use of any equipmen...

Page 6: ...abinet by application of pressure to the surface if the device has been positioned horizontally integral condensing unit wait two hours before activating it Packing and protective film should be disposed off as indicated by the local authorities The equipment must not be installed within explosive amblence In the open air or exposed to rain the correct siting is distant from direct sources radiato...

Page 7: ...electrical safety feature have this introduced by a qualified person by means of a omnipolar switch as indicated in the safety regulations with a means of a omnipolar switch as indicated in the safety regulations with a minimum clearance of the contacts of 3 mm where the cabinet has to be installed at some distance from the electrical source ensure that the conforms to the local regulations Cabine...

Page 8: ...level of the equipment fitted with integral hermetic condensing unit does not exceed 70 dB it is therefore not necessary to provide sound insulation Under normal conditions the equipment does not generate vibrations which affect surroundings 5 2 POSSIBLE USAGES Do not utilise the equipment to store medical supplies the optimum operational ambient temperatures are between 10 32 ...

Page 9: ...7 6 USAGE 6 1 ACTION These devices are activated by one switches and an electronic control panel 6 2 Meaning of the button ...

Page 10: ...8 6 3 Selecting the BLAST CHILLING cycle ...

Page 11: ...word set is 22 the display will scroll the list of type C parameters CONFIGURATION otherwise the list of type F parameters FREQUENT Set the desired value 5 Press START The display will show the parameter name This is the current value of the parameter 6 Press UP or DOWN The value on the display will increase or decrease Set the desire value 7 Press START The display will show the parameter name ag...

Page 12: ...nthe table below according to the list on the display with the corresponding name and icon To directly access the list of parameters grouped bycategory press the PRG button for at least 1 second and to modify the parameter press DOWN START UP Category Paraneters Message Icon Probe parameters pro Control parameters r Ctl Compressor parameters c CMP Defrost parameters d dEF Alarm parameters A ALM Fa...

Page 13: ...ch the instrument off 2 switch the instrument back on holding the PRG button until the value bn0 is shown on the display 3 select the set of default parameters between 0 and Hdn using the DOWN and UP buttons 4 press the START button until the message Std is shown on the display 7 MANITENANCE 7 1 PERIODIC CLEANING For hygienic reasons and improved performance clean at least once a month the interna...

Page 14: ...roper air circulation 8 3 If the cabinet leaks water make that The collecting container or the device for condensing water elimination are not damaged The discharge outlets are not blocked or obstructed The cabinet has been properly leveled 8 4 If the cabinet is unacceptably noisy make sure that The frame does not have loose screws or bolts The cabinet has been laid in a stable position and correc...

Page 15: ...XISTING LOCAL STATUTES ARE THE RESPONSIBILITY OF THE OWER Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwate...

Page 16: ...14 Circuit diagram ...

Page 17: ...cle from 65 C to 10 C t 90 min Blast freezing cycle from 65 C to 18 C t 270 min Contact details Yindu Kitchen Equipment Co Ltd No 1 Xingxing Road Xingqiao District Yuhang Hangzhou Zhejiang 311100 China Model EBF 03 EBF 05 Fast cooling performance per cycle kg 10Kg 90 3 in 90 Min 25Kg 90 3 in 90 Min Fast freezing performance per cycle kg 5Kg 90 18 in 240 Min 15Kg 90 18 in 240 Min Rated voltage 220 ...

Page 18: ...load capacity 15 00 kg Refrigerant charge 0 15 kg Blast chilling cycle from 65 C to 10 C t 72 min Blast freezing cycle from 65 C to 18 C t 240 min Contact details Yindu Kitchen Equipment Co Ltd No 1 Xingxing Road Xingqiao District Yuhang Hangzhou Zhejiang 311100 China OFFICIAL APPROVAL AND RULES Our products full fill the present E U rules including the CE mark of the European official approval Ma...

Page 19: ...17 Summary of operating parameters Signals on the display ...

Page 20: ...event possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Reviews: