background image

TS150-E2

Pedestal Server

Summary of Contents for TS150-E2

Page 1: ...TS150 E2 Pedestal Server ...

Page 2: ... product is defaced or missing ASUS PROVIDES THIS MANUAL AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL ASUS ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LO...

Page 3: ...tup Hardware setup 2 1 Preparation 2 2 2 2 Removing the side cover 2 2 2 3 Motherboard information 2 4 2 4 Central Processing Unit CPU 2 5 2 4 1 Installing the CPU 2 5 2 4 2 Installing the CPU fan and heatsink assembly 2 8 2 5 System memory 2 10 2 5 1 Overview 2 10 2 5 2 Memory configurations 2 10 2 5 3 Installing a DIMM 2 12 2 5 4 Removing a DIMM 2 12 2 6 Installing a hard disk drive 2 13 2 7 Ins...

Page 4: ... 5 Chapter 5 Chapter 5 BIOS information BIOS information BIOS information BIOS information BIOS information 5 1 Managing and updating your BIOS 5 2 5 1 1 Creating a bootable floppy disk 5 2 5 1 2 AFUDOS utility 5 3 5 1 3 ASUS EZ Flash utility 5 6 5 1 4 ASUS CrashFree BIOS 2 utility 5 7 5 1 5 ASUS Update utility 5 9 5 2 BIOS setup program 5 12 5 2 1 BIOS menu screen 5 13 5 2 2 Menu bar 5 13 5 2 3 N...

Page 5: ... 6 RAID configuration and driver installation RAID configuration and driver installation RAID configuration and driver installation RAID configuration and driver installation RAID configuration and driver installation 6 1 RAID configurations 6 2 6 1 1 RAID definitions 6 2 6 1 2 Installing hard disk drives 6 3 6 1 3 Setting the RAID item in BIOS 6 3 6 1 4 Using the RAID configuration utility 6 3 6 ...

Page 6: ...d Hat Linux 9 0 6 22 Appendix Appendix Appendix Appendix Appendix Reference information Reference information Reference information Reference information Reference information A 1 Simple fixes A 2 A 2 Power supply specification A 4 A 2 1 Input characteristics A 4 A 2 2 Output Characteristics A 4 A 2 3 Over Voltage Protection OVP A 4 ...

Page 7: ...e user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Department of Communica...

Page 8: ... the correct voltage in your area If you are not sure about the voltage of the electrical outlet you are using contact your local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your retailer Operation safety Operation safety Operation safety Operation safety Operation safety Before installing any component to the server carefu...

Page 9: ... 4 4 Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information This chapter gives information about the motherboard that comes with the server This chapter includes the motherboard layout jumper settings and connector locations 5 5 5 5 5 Chapter 5 BIOS information Chapter 5 BIOS informat...

Page 10: ...on to prevent damage to the components when trying to complete a task NOTE NOTE NOTE NOTE NOTE Tips and additional information to help you complete a task IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT Instructions that you MUST follow to complete a task Conventions used in this guide Conventions used in this guide Conventions used in this guide Conventions used in this guide Conventions used i...

Page 11: ...SUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 This chapter describes the general features of the barebone server including sections on the front panel and rear panel specifications Chapter 1 Product introduction ...

Page 12: ... configurations Item Description Item Description Item Description Item Description Item Description 1 ASUS TS150 E2 server with ASUS P5CR VM motherboard 300 W power supply Optical drive Floppy disk drive Chassis fan CPU fan and heatsink assembly 2 AC power cord 3 System screws and labels 4 Support CD including drivers and utilities 5 User guide 6 Optional items Second hard disk drive cage with re...

Page 13: ...er supply Power supply Power supply Power supply Power supply Pedestal with front panel I O ports ASUS P5CR VM uATX form factor 9 6 in x 9 6 in Northbridge Intel E7221 Memory Controller Hub MCH Southbridge Intel ICH6R LGA775 socket for Intel Pentium 4 processor with Extended Memory 64 bit Technology EM64T Supports Intel Hyper Threading Technology 800 533 MHz Dual channel memory architecture 4 x 24...

Page 14: ... Front panel I O Front panel I O Front panel I O ports cover ports cover ports cover ports cover ports cover Optical drive Optical drive Optical drive Optical drive Optical drive Floppy disk Floppy disk Floppy disk Floppy disk Floppy disk d r i v e d r i v e d r i v e d r i v e d r i v e Empty 5 25 inch bays Empty 5 25 inch bays Empty 5 25 inch bays Empty 5 25 inch bays Empty 5 25 inch bays Power ...

Page 15: ... keyboard port P S2 keyboard port P S2 keyboard port Serial port Serial port Serial port Serial port Serial port Parallel port Parallel port Parallel port Parallel port Parallel port VGA port VGA port VGA port VGA port VGA port Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Voltage selector Voltage selector Voltage selector Voltage selector Voltage select...

Page 16: ...d 4 CPU socket 5 DDR2 DIMM sockets 6 PCI Express x1 slot 7 PCI Express x8 slot 8 PCI slots 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 9 Floppy disk drive connector 10 IDE connector 11 Serial ATA connectors 12 Optical drive 13 Empty 5 25 inch drive bays 14 Floppy disk drive 15 HDD bay 16 Detachable HDD cage 4 4 4 4 4 5 5 5 5 5 10 10 10 10 10 1 1 1 1 15 5 5 5 5 16 16 16 16 16 1 1 1 1 11 1 1 1 1 3 3 3 3 3 6 6 6 6...

Page 17: ...50 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 2 1 This chapter lists the hardware setup procedures that you have to perform when installing or removing system components Chapter 2 Hardware setup ...

Page 18: ...eed to install the following components to the barebone server 1 Central processing unit CPU 2 Dual Inline Memory Module s DIMMs 3 Hard disk drive 4 5 25 inch drive s 5 Expansion card s Tool Tool Tool Tool Tool You need a Phillips cross screw driver to install some system components 2 2 Removing the side cover To remove the side cover 1 Locate the two side cover locks 1 1 1 1 1 1 1 1 1 1 2 Press t...

Page 19: ...tructure Without the side cover the internal structure and installed components of the barebone server appear as shown in the following picture Perform the procedures in the succeeding sections to install the CPU system memory disk drives and expansion cards 4 4 4 4 4 3 3 3 3 3 Make sure that you unplug the power cord before removing the side cover Take extra care when removing the side cover Keep...

Page 20: ...low Refer to Chapter 4 Motherboard information for detailed information on the motherboard Make sure to unplug the power cord before installing or removing any motherboard component or connection Failure to do so may cause you physical injury and may damage motherboard components Place this side Place this side Place this side Place this side Place this side towards the towards the towards the tow...

Page 21: ...he CPU heatsink and the retention mechanism If the instructions in this section do not match the CPU documentation follow the latter Upon purchase of the motherboard make sure that the PnP cap is on the socket and the socket contacts are not bent Contact your retailer immediately if the PnP cap is missing or if you see any damage to the PnP cap socket contacts motherboard components ASUS will shou...

Page 22: ...ey should fit into the CPU notch Alignment key Alignment key Alignment key Alignment key Alignment key Gold triangle mark Gold triangle mark Gold triangle mark Gold triangle mark Gold triangle mark Load plate Load plate Load plate Load plate Load plate A B 2 Press the load lever with your thumb A then move it to the left B until it is released from the retention tab Retention tab Retention tab Ret...

Page 23: ...the BIOS to ensure system stability and performance Make sure to enable the Hyper Threading Technology item in BIOS before installing a supported operating system For more information on Hyper Threading Technology visit www intel com info hyperthreading To use the Hyper Threading Technology on this motherboard 1 Install an Intel Pentium 4 CPU that supports Hyper Threading Technology 2 Power up the...

Page 24: ...le is closest to the CPU_FAN1 connector An X pad comes pre installed under the motherboard If you use the push pin heatsink and fan assembly make sure to remove the X pad first CPU fan screw CPU fan screw CPU fan screw CPU fan screw CPU fan screw CPU fan screw hole CPU fan screw hole CPU fan screw hole CPU fan screw hole CPU fan screw hole When you buy a boxed Intel Pentium 4 processor the package...

Page 25: ... fan connector Hardware monitoring errors can occur if you fail to plug this connector If there is only one CPU fan cable connect it to the connector labeled CPU_FAN1 Failure to do so may cause hardware monitoring errors 2 Fasten the screws in a diagonal sequence to secure the heatsink and fan assembly in place P5CR VM P5CR VM CPU fan connectors GND FANPWR3 FANOUT7 CPU_FAN2 CPU_FAN1 GND FANPWR2 FA...

Page 26: ... 2 2 5 2 Memory configurations Memory configurations Memory configurations Memory configurations Memory configurations You may install 256 MB 512 MB and 1 GB unbuffered ECC DDR2 DIMMs into the DIMM sockets Always install DIMMs with the same CAS latency For optimum compatibility we recommend that you obtain memory modules from the same vendor Due to chipset limitation the available memory space dep...

Page 27: ... ALLOCATION DIMM_A1 DIMM_A1 DIMM_A1 DIMM_A1 DIMM_A1 D I M M _ B 1 D I M M _ B 1 D I M M _ B 1 D I M M _ B 1 D I M M _ B 1 DIMM_A2 DIMM_A2 DIMM_A2 DIMM_A2 DIMM_A2 D I M M _ B 2 D I M M _ B 2 D I M M _ B 2 D I M M _ B 2 D I M M _ B 2 Channel Channel Channel Channel Channel of DIMMS of DIMMS of DIMMS of DIMMS of DIMMS SINGLE 1 3 DUAL 2 4 Install only identical memory modules For optimum compatibility...

Page 28: ...ly seated 2 5 4 2 5 4 2 5 4 2 5 4 2 5 4 Removing a DIMM Removing a DIMM Removing a DIMM Removing a DIMM Removing a DIMM Follow these steps to remove a DIMM 1 Simultaneously press the retaining clips outward to unlock the DIMM 2 Remove the DIMM from the socket A DDR2 DIMM is keyed with a notch so that it fits in only one direction Do not force a DIMM into a socket to avoid damaging the DIMM The DDR...

Page 29: ... a Master Slave device You may purchase a second hard disk drive cage to install an additional HDD Refer to the next chapter for details Hard disk drive installation Hard disk drive installation Hard disk drive installation Hard disk drive installation Hard disk drive installation The detachable hard disk drive cage accommodates one Serial ATA hard disk drive To install a Serial ATA hard disk driv...

Page 30: ... cage Screw holes Screw holes Screw holes Screw holes Screw holes 4 Reinstall the HDD cage to the chassis Align the HDD cage and bay assembly rails then carefully push the HDD cage until it is flushed to the chassis DO NOT DO NOT DO NOT DO NOT DO NOT install a hard disk drive to the lower bay of the cage 5 Connect one end of the supplied 7 pin SATA cable to the SATA connector at the back of the dr...

Page 31: ...he power connector at the back of the drive Connect the 15 pin Serial ATA power plug to the Serial ATA power connector at the back of the drive OR Use either the SATA power connector O R O R O R O R O R the legacy 4 pin power connector DO NOT DO NOT DO NOT DO NOT DO NOT use both to prevent damage to components and to keep the system from becoming unstable ...

Page 32: ...he power cable before installing or removing any system components Failure to do so may cause severe damage to the motherboard and other system components 2 7 1 2 7 1 2 7 1 2 7 1 2 7 1 Removing the front panel cover Removing the front panel cover Removing the front panel cover Removing the front panel cover Removing the front panel cover To remove the front panel cover 1 Locate and remove two scre...

Page 33: ...he front panel cover hook inward until it detaches from the chassis hole 4 On the other side of the system locate three front panel cover hooks Press the hooks inward until the front panel cover detaches from the chassis 5 Carefully remove the front panel cover then set aside 4 4 4 4 4 5 5 5 5 5 3 3 3 3 3 ...

Page 34: ...you intend to use Push the knock down metal cover in and out of the chassis until it is removed 2 Carefully insert the drive to the bay then push it inward until it is flushed to the chassis front panel 3 Align the optical drive and bay screw holes 4 Secure the drive with two screws on both sides of the bay Screw holes Screw holes Screw holes Screw holes Screw holes 3 3 3 3 3 4 4 4 4 4 1 1 1 1 1 1...

Page 35: ...connector on the drive 6 Connect a 4 pin power plug from the power supply unit to the drive power connector 6 6 6 6 6 5 5 5 5 5 7 Remove the front panel bay cover opposite the drive bay you used by pressing the hooks inward Follow the same procedures when installing additional optical drives 8 8 8 8 8 7 7 7 7 7 8 Reinstall the front panel and side covers when done ...

Page 36: ...so may cause severe damage to both the motherboard and the components To install an expansion card 1 Before installing the expansion card read the documentation that came with it and make the necessary hardware settings for the card 2 Lay the system on its side on a flat stable surface 3 Remove the metal bracket opposite the slot that you intend to use Keep the metal bracket screw for later use 5 ...

Page 37: ...stem components or when replacing a defective component This section tells how to remove the following components 1 Floppy disk drive FDD 2 System fan 3 Carefully pull the FDD from the chassis Set the FDD aside 2 Unlock the FDD bay by moving the drive bay lock toward the direction of the front panel 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 2 9 1 2 9 1 2 9 1 2 9 1 2 9 1 Removing the floppy disk drive Removing...

Page 38: ...the chassis fan To remove the chassis fan 1 Disconnect the chassis fan cable from the REAR_FAN1 connector on the motherboard 2 Locate and remove four chassis fan screws at the rear panel Keep the screws for later use Hold the chassis fan with one hand while removing the chassis fan screws 2 2 2 2 2 3 3 3 3 3 3 Remove the chassis fan then set aside 3 Move the drive bay lock toward the rear panel to...

Page 39: ...and performance Refer to the picture below when arranging cables See Chapter 4 Motherboard information or detailed information on motherboard connectors 1 4 pin ATX 12V power plug 2 24 pin ATX power plug 3 Floppy disk drive ribbon cable 4 Front panel USB 2 0 cable 5 IDE signal cable Standard cables connected to the motherboard Standard cables connected to the motherboard Standard cables connected ...

Page 40: ...he side cover hooks to the chassis rail on the side of the chassis 2 Fit the side cover the cover toward the chassis until it fits 3 Slide the cover toward the front until it snaps in place 2 11 Replacing the side cover After installing all components and re connecting cables replace the side cover by following these instructions 3 3 3 3 3 1 1 1 1 1 2 2 2 2 2 ...

Page 41: ...3 1 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 This chapter describes how to install optional components into the barebone server Chapter 3 Installation options ...

Page 42: ...rd Second hard disk drive cage disk drive cage disk drive cage disk drive cage disk drive cage HDD cage HDD cage HDD cage HDD cage HDD cage retention base retention base retention base retention base retention base You need to install the retention base to the chassis before installing the second HDD cage To install the retention base 1 Lay the system on its side on a flat stable surface 2 Locate ...

Page 43: ...3 3 3 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 ASUS TS150 E2 3 Insert the retention base hooks to the holes until they fit in place 4 Secure the retention base with two screws 5 Turn the system upright ...

Page 44: ...d disk drive 1 Insert an HDD to the lower bay of the drive cage Make sure that the HDD screw holes align with the drive cage screw holes 2 Secure the HDD to the cage with two screws with metal washers on each side of the bay DO NOT DO NOT DO NOT DO NOT DO NOT install a hard disk drive to the upper cage of the bay 3 Connect one end of the 7 pin Serial ATA cable to the connector at the back of the d...

Page 45: ...then slightly push the cage until it clicks in place 5 Connect the other end of the Serial ATA cable to the SATA connector on the motherboard 6 Connect a 4 pin power plug from the power supply unit to the power connectors at the back of the drive Use a Serial ATA power cable and adapter for Serial ATA HDD s without a 4 pin power connector ...

Page 46: ... bracket 1 Lay the system on its side on a flat stable surface 2 Locate two retention bracket screw holes on the chassis floor Install all necessary expansion cards before installing the expansion card holder Assembly Assembly Assembly Assembly Assembly L o c k L o c k L o c k L o c k L o c k Adjusting Adjusting Adjusting Adjusting Adjusting s l o t s s l o t s s l o t s s l o t s s l o t s Card h...

Page 47: ... retention bracket notch as shown 2 Turn the expansion card holder upright 3 Press the locking lever then insert the hooks to the chassis holes 4 Secure the expansion card holder with one screw 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 3 Place the retention bracket over the chassis floor screw holes then secure the bracket with two screws 4 Turn the chassis upright 3 3 3 3 3 ...

Page 48: ...rd holder at level with the expansion card Do not use the smaller card holder which is for long AGP cards The P5CR VM motherboard does not have an AGP slot The other card holders are for long PCI cards 2 Loosen the screw s to adjust the card holder forward or sideward until its groove fits the edge of the expansion card 3 Fasten the card holder screw s 4 Follow the same steps in holding other long...

Page 49: ... ASUS TS15 E2 ASUS TS15 E2 ASUS TS15 E2 This chapter gives information about the motherboard that comes with the server This chapter includes the motherboard layout jumper settings and connector locations Chapter 4 Motherboard info ...

Page 50: ...le DDR2 DIMM_A2 64 bit 240 pin module DDR2 DIMM_B2 64 bit 240 pin module SATA4 AUX_PANEL1 REAR_FAN1 KBPWR1 LGA775 PS 2KBMS T Mouse B Keyboard LAN1 LAN2 USB12 COM1 PARALLEL PORT VGA1 USBPW12 REAR_FAN2 ATX12V1 FM_CPU1 CPU_FAN1 FRNT_FAN1 FRNT_FAN2 PANEL1 RECOVERY1 USB34 USBPW34 HDLED1 BUZZ1 FLOPPY1 BMCCONN1 TRPWR1 CLRTC1 BPSMB1 SB_PWR1 COM2 LAN_EN1 Broadcom BCM5721 Broadcom BCM5721 Intel ICH6R BMCSOC...

Page 51: ... USBPW12 USBPW34 USBPW56 4 5 USBPW78 4 Keyboard and mouse power 3 pin KBPWR1 4 6 5 Gigabit LAN controller setting 3 pin LAN_EN1 4 6 6 Gigabit LAN controller setting 3 pin LAN_EN2 4 7 7 BIOS recovery 3 pin RECOVERY1 4 8 Rear panel connectors Rear panel connectors Rear panel connectors Rear panel connectors Rear panel connectors Page Page Page Page Page 1 PS 2 mouse port 4 10 2 Parallel port 4 10 3 ...

Page 52: ... USB34 USB56 USB78 4 13 8 SSI power connectors 24 pin ATXPWR1 4 pin ATX12V1 4 14 9 Serial port connector 10 1 pin COM2 4 15 10 Backplane SMBus connector 6 1 pin BPSMB1 4 15 11 Power supply SMBus connector 5 pin PSUSMB1 4 16 12 BMC connector 16 pin BMCCONN1 4 16 13 TRPWR connector 2 pin TRPWR1 4 17 14 Auxiliary panel connector 20 pin AUX_PANEL1 4 18 Chassis Intrusion connector 3 pin CASEOPEN LAN1 l...

Page 53: ...system setup information such as system passwords To erase the RTC RAM 1 Turn OFF the computer and unplug the power cord 2 Remove the onboard battery 3 Move the jumper cap from pins 1 2 default to pins 2 3 Keep the cap on pins 2 3 for about 5 10 seconds then move the cap back to pins 1 2 4 Reinstall the battery 5 Plug the power cord and turn ON the computer 6 Hold down the Del key during the boot ...

Page 54: ...ly that can provide 500mA on the 5VSB lead for each USB port otherwise the system would not power up The total current consumed must NOT exceed the power supply capability 5VSB whether under normal condition or in sleep mode 2 2 2 2 2 CPU fan mode selection 3 pin FM_CPU1 FM_CPU2 CPU fan mode selection 3 pin FM_CPU1 FM_CPU2 CPU fan mode selection 3 pin FM_CPU1 FM_CPU2 CPU fan mode selection 3 pin F...

Page 55: ...pace Bar or click the mouse This feature requires an ATX power supply that can supply at least 1A on the 5VSB lead and a corresponding setting in the BIOS 5 5 5 5 5 Gigabit LAN controller setting 3 pin LAN_EN1 Gigabit LAN controller setting 3 pin LAN_EN1 Gigabit LAN controller setting 3 pin LAN_EN1 Gigabit LAN controller setting 3 pin LAN_EN1 Gigabit LAN controller setting 3 pin LAN_EN1 These jump...

Page 56: ... setting 3 pin LAN_EN2 Gigabit LAN controller setting 3 pin LAN_EN2 Gigabit LAN controller setting 3 pin LAN_EN2 Gigabit LAN controller setting 3 pin LAN_EN2 Gigabit LAN controller setting 3 pin LAN_EN2 These jumpers allow you to enable or disable the onboard Broadcom BCM5705E Gigabit LAN controller Set to pins 1 2 to activate the Gigabit LAN feature P5CR LS P5CR VM LAN_EN2 setting Enable Default ...

Page 57: ... BIOS 1 Turn OFF your computer and unplug the power cord 2 Move the jumper cap from pins 1 2 default to pins 2 3 3 Insert a floppy disk with the original or updated BIOS file 4 Plug the power cord and turn ON the computer 5 The system searches for the BIOS file in the floppy then reflashes the BIOS 6 When finished shut down your computer 7 Replace the jumper cap from pins 2 3 to pins 1 2 8 Reboot ...

Page 58: ...dapter VGA port Video Graphics Adapter VGA port Video Graphics Adapter VGA port Video Graphics Adapter VGA port Video Graphics Adapter VGA port This port is for a VGA monitor or other VGA compatible devices 7 7 7 7 7 LAN 1 RJ 45 port LAN 1 RJ 45 port LAN 1 RJ 45 port LAN 1 RJ 45 port LAN 1 RJ 45 port This port allows Gigabit connection to a Local Area Network LAN through a network hub Refer to the...

Page 59: ...2 4 3 2 4 3 2 Internal connectors Internal connectors Internal connectors Internal connectors Internal connectors 1 1 1 1 1 Floppy disk drive connector 34 1 pin FLOPPY1 Floppy disk drive connector 34 1 pin FLOPPY1 Floppy disk drive connector 34 1 pin FLOPPY1 Floppy disk drive connector 34 1 pin FLOPPY1 Floppy disk drive connector 34 1 pin FLOPPY1 This connector is for the provided floppy disk driv...

Page 60: ...r on the motherboard a black connector for an Ultra DMA 100 66 IDE slave device optical drive hard disk drive and a gray connector for an Ultra DMA 100 66 IDE master device hard disk drive If you install two hard disk drives you must configure the second drive as a slave device by setting its jumper accordingly Refer to the hard disk documentation for the jumper settings Pin 20 on the IDE connecto...

Page 61: ...ou must install Windows 2000 Service Pack 4 Windows 2000 Advanced Server or Windows Server 2003 before using Serial ATA hard disk drives The Serial ATA RAID feature RAID 0and RAID 1 is available only if you are using Windows 2000 2003 Server Use only two Serial ATA RAID connectors for each RAID 0 and RAID 1 set When using the connectors in S S S S Standard IDE tandard IDE tandard IDE tandard IDE t...

Page 62: ...N1 2 FRNT_FAN1 2 The fan connectors support cooling fans of 350 mA 740 mA 8 88 W max or a total of 2 1 A 4 44 A 53 28 W max at 12V Connect the fan cables to the fan connectors on the motherboard making sure that the black wire of each cable matches the ground pin of the connector Do not forget to connect the fan cables to the fan connectors Insufficient air flow inside the system may damage the mo...

Page 63: ...Hard disk activity LED connector 4 pin HDLED1 Hard disk activity LED connector 4 pin HDLED1 Hard disk activity LED connector 4 pin HDLED1 Hard disk activity LED connector 4 pin HDLED1 This connector supplies power to the hard disk activity LED The read or write activities of any device connected to the primary secondary SCSI connectors or the SATA connectors cause this LED to light up Never connec...

Page 64: ... the connectors completely fit Use of an SSI 12 V Specification 2 0 compliant power supply unit PSU that provides a minimum power of 450 W is recommended for a fully configured system Do not forget to connect the 4 pin ATX 12 V power plug otherwise the system will not boot up Use of a PSU with a higher power output is recommended when configuring a system with more power consuming devices The syst...

Page 65: ...es Devices communicate with an SMBus host and or other SMBus devices using the SMBus interface 8 8 8 8 8 Serial port connector 10 1 pin COM2 Serial port connector 10 1 pin COM2 Serial port connector 10 1 pin COM2 Serial port connector 10 1 pin COM2 Serial port connector 10 1 pin COM2 This connector is for a serial COM port Connect the serial port module cable to this connector then install the mod...

Page 66: ... supply SMBus connector 5 pin PSUSMB1 Power supply SMBus connector 5 pin PSUSMB1 Power supply SMBus connector 5 pin PSUSMB1 Power supply SMBus connector 5 pin PSUSMB1 Power supply SMBus connector 5 pin PSUSMB1 This connector allows you to connect SMBus System Management Bus devices Devices communicate with an SMBus host and or other SMBus devices using the SMBus interface P5CR VM P5CR VM Power sup...

Page 67: ...SUS TS150 E2 12 12 12 12 12 TRPWR connector 2 pin TRPWR connector 2 pin TRPWR connector 2 pin TRPWR connector 2 pin TRPWR connector 2 pin TRPWR1 TRPWR1 TRPWR1 TRPWR1 TRPWR1 This connector is for an internal temperature sensor probe P5CR VM P5CR VM TRPWR connector TRPWR1 1 SENSER GND ...

Page 68: ...tivity LED 2 pin LAN2_LINKACTLED LAN2 link activity LED 2 pin LAN2_LINKACTLED This 2 pin connector is for the LAN2 Activity LED Connect the LAN2 Activity LED cable to this connector This LED blinks during a network activity and lights up when linked Locator LED 1 2 pin LOCATORLED1 Locator LED 1 2 pin LOCATORLED1 Locator LED 1 2 pin LOCATORLED1 Locator LED 1 2 pin LOCATORLED1 Locator LED 1 2 pin LO...

Page 69: ...tem warning speaker The speaker allows you to hear system beeps and warnings ATX power button soft off button Yellow 2 pin PWRBTN ATX power button soft off button Yellow 2 pin PWRBTN ATX power button soft off button Yellow 2 pin PWRBTN ATX power button soft off button Yellow 2 pin PWRBTN ATX power button soft off button Yellow 2 pin PWRBTN This connector is for the system power button Pressing the...

Page 70: ...Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information Chapter 4 Motherboard information 4 22 4 22 4 22 4 22 4 22 ...

Page 71: ... AP1710 E1 ASUS AP1710 E1 ASUS AP1710 E1 ASUS AP1710 E1 ASUS AP1710 E1 This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters Chapter 5 BIOS information ...

Page 72: ...isk Creating a bootable floppy disk Creating a bootable floppy disk Creating a bootable floppy disk Creating a bootable floppy disk 1 Do either one of the following to create a bootable floppy disk DOS environment a Insert a 1 44MB floppy disk into the drive b At the DOS prompt type format A S then press Enter Windows Server 2003 a Insert a 1 44 MB floppy disk to the floppy disk drive b Click Star...

Page 73: ...tart Start Start Start Start then select Run Run Run Run Run d In the Open Open Open Open Open field type D bootdisk makeboot a assuming that D is your optical drive letter e Press Enter then follow screen instructions to continue 2 Copy the original or the latest motherboard BIOS file to the bootable floppy disk Main filename Main filename Main filename Main filename Main filename Extension name ...

Page 74: ... to file ok A 2 Copy the AFUDOS utility afudos exe from the motherboard support CD to the bootable floppy disk you created earlier 3 Boot the system in DOS mode then at the prompt type afudos i filename where filename is the latest or the original BIOS file on the bootable floppy disk Updating the BIOS file Updating the BIOS file Updating the BIOS file Updating the BIOS file Updating the BIOS file...

Page 75: ...ng flash BIOS Reading file done Reading flash done Advance Check Erasing flash done Writing flash 0x0008CC00 9 4 The utility verifies the file and starts updating the BIOS Do not shut down or reset the system while updating the BIOS to prevent system boot failure A afudos iP5CR VM ROM pbnc AMI Firmware Update Utility Version 1 19 ASUS V2 07 03 11 24BB Copyright C 2002 American Megatrends Inc All r...

Page 76: ... and rename the same to P5CR VM ROM P5CR VM ROM P5CR VM ROM P5CR VM ROM P5CR VM ROM 2 Save the BIOS file to a floppy disk then restart the system 3 Press Alt F2 during POST to display the following EZFlash starting BIOS update Checking for floppy 4 Insert the floppy disk that contains the BIOS file to the floppy disk drive When the correct BIOS file is found EZ Flash performs the BIOS update proce...

Page 77: ...IOS from a floppy disk 1 Turn on the system 2 Insert the floppy disk with the original or updated BIOS file to the floppy disk drive 3 The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file Bad BIOS checksum Starting BIOS recovery Checking for floppy 4 Restart the system after the utility completes the updating process Bad BIOS che...

Page 78: ...loppy disk from the floppy disk drive then turn on the system 2 Insert the support CD to the optical drive 3 The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file 4 Restart the system after the utility completes the updating process DO NOT shut down or reset the system while updating the BIOS Doing so can cause system boot failure...

Page 79: ...ity is copied to your system 5 1 5 5 1 5 5 1 5 5 1 5 5 1 5 ASUS Update utility ASUS Update utility ASUS Update utility ASUS Update utility ASUS Update utility The ASUS Update is a utility that allows you to manage save and update the motherboard BIOS in Windows environment The ASUS Update utility allows you to Save the current BIOS file Download the latest BIOS file from the Internet Update the BI...

Page 80: ...Internet Updating the BIOS through the Internet Updating the BIOS through the Internet To update the BIOS through the Internet 1 Launch the ASUS Update utility from the Windows desktop by clicking Start Start Start Start Start Programs Programs Programs Programs Programs ASUS ASUS ASUS ASUS ASUS ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUS...

Page 81: ...e ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate The ASUS Update main window appears 2 Select Update BIOS from a Update BIOS from a Update BIOS from a Update BIOS from a Update BIOS from a file file file file file option from the drop down menu then click Next Next Next Next Next 4 From the FTP site select the BIOS version that you wish to download Click Next 5 Follow the screen...

Page 82: ...with the opportunity to run this program Press Del during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing Ctrl Alt Delete or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the firs...

Page 83: ...rom one screen to another 5 2 3 5 2 3 5 2 3 5 2 3 5 2 3 Navigation keys Navigation keys Navigation keys Navigation keys Navigation keys At the bottom right corner of a menu screen are the navigation keys for that particular menu Use the navigation keys to select items in the menu and change the settings System Time 16 37 21 System Date Wed 10 10 2004 Legacy Diskette A 1 44M 3 5 in Primary IDE Mast...

Page 84: ...list of options Refer to 5 2 7 Pop up window 5 2 7 5 2 7 5 2 7 5 2 7 5 2 7 Pop up window Pop up window Pop up window Pop up window Pop up window Select a menu item then press Enter to display a pop up window with the configuration options for that item 5 2 8 5 2 8 5 2 8 5 2 8 5 2 8 Scroll bar Scroll bar Scroll bar Scroll bar Scroll bar A scroll bar appears on the right side of a menu screen when t...

Page 85: ... 3 3 5 3 3 Legacy Diskette A 1 44M 3 5 in Legacy Diskette A 1 44M 3 5 in Legacy Diskette A 1 44M 3 5 in Legacy Diskette A 1 44M 3 5 in Legacy Diskette A 1 44M 3 5 in Sets the type of floppy drive installed Configuration options Disabled 360K 5 25 in 1 2M 5 25 in 720K 3 5 in 1 44M 3 5 in 2 88M 3 5 in Refer to section 5 2 1 BIOS menu screen for information on the menu screen items and how to navigat...

Page 86: ...k Mode PIO Mode Async DMA Ultra DMA and SMART monitoring These values are not user configurable These items show Not Detected if no IDE device is installed in the system Type Auto Type Auto Type Auto Type Auto Type Auto Selects the type of IDE drive Setting to Auto allows automatic selection of the appropriate IDE device type Select CDROM if you are specifically configuring a CD ROM drive Select A...

Page 87: ...nfiguration The items in this menu allow you to set or change the configurations for the IDE devices installed in the system Select an item then press Enter if you want to configure the item IDE Configuration Configure SATA As Standard IDE Onboard IDE Operate Mode Enhanced Mode Enhanced Mode Support On S ATA IDE Detect Time Out Sec 35 Configure SATA As Standard IDE Configure SATA As Standard IDE C...

Page 88: ... IDE Operate Mode Onboard IDE Operate Mode Onboard IDE Operate Mode and its submenu items appear only when the Configure SATA As Configure SATA As Configure SATA As Configure SATA As Configure SATA As item is set to Standard IDE ALPE and ASP Disabled Enables or disables the ALPE and ASP Configuration options Disabled Enabled Stagger Spinup Support Disabled Stagger Spinup Support Disabled Stagger S...

Page 89: ...s The BIOS automatically detects the items in this menu AMI BIOS AMI BIOS AMI BIOS AMI BIOS AMI BIOS Displays the auto detected BIOS information Processor Processor Processor Processor Processor Displays the auto detected CPU specification System Memory System Memory System Memory System Memory System Memory Displays the auto detected system memory AMIBIOS Version 08 00 10 Build Date 11 08 04 Proc...

Page 90: ...nd USB Devices Enabled USB Devices Enabled USB Devices Enabled USB Devices Enabled USB Devices Enabled items show the auto detected values If no USB device is detected the item shows N o n e N o n e N o n e N o n e N o n e 5 4 1 5 4 1 5 4 1 5 4 1 5 4 1 USB Configuration USB Configuration USB Configuration USB Configuration USB Configuration The items in this menu allow you to change the USB relate...

Page 91: ... Legacy USB Support Auto Allows you to enable or disable support for legacy USB devices Setting to Auto allows the system to detect the presence of USB devices at startup If detected the USB controller legacy mode is enabled If no USB device is detected the legacy USB support is disabled Configuration options Disabled Enabled Auto USB 2 0 Controller Enabled USB 2 0 Controller Enabled USB 2 0 Contr...

Page 92: ... the remote access feature Configuration options Disabled Enabled Serial port number COM1 Serial port number COM1 Serial port number COM1 Serial port number COM1 Serial port number COM1 Sets the serial port for console redirection Make sure the selected port is enabled Configuration options COM1 COM2 Base Address IRQ 3F8h 4 Base Address IRQ 3F8h 4 Base Address IRQ 3F8h 4 Base Address IRQ 3F8h 4 Ba...

Page 93: ...emory Display Delay No Delay Sredir Memory Display Delay No Delay Gives the delay period in seconds to display memory information Configuration options No Delay Delay 1 Sec Delay 2 Sec Delay 4 Sec 5 4 4 5 4 4 5 4 4 5 4 4 5 4 4 CPU Configuration CPU Configuration CPU Configuration CPU Configuration CPU Configuration The items in this menu show the CPU related information that the BIOS automatically...

Page 94: ...x CPUID Value Limit Disabled Max CPUID Value Limit Disabled Max CPUID Value Limit Disabled Max CPUID Value Limit Disabled Enable this item to boot legacy operating systems that cannot support CPUs with extended CPUID functions Configuration options Disabled Enabled Enhanced C1 Control Auto Enhanced C1 Control Auto Enhanced C1 Control Auto Enhanced C1 Control Auto Enhanced C1 Control Auto When set ...

Page 95: ...tion options Disabled Enabled The following sub items appear when this item is Disabled DRAM CAS Latency 5 Clocks Controls the latency between the SDRAM read command and the time the data actually becomes available Configuration options 5 Clocks 4 Clocks 3 Clocks DRAM RAS Precharge 4 Clocks Controls the idle clocks after issuing a precharge command to the DDR SDRAM Configuration options 2 Clocks 3...

Page 96: ...r Path 2 Auto Hyper Path 2 Auto Hyper Path 2 Auto Allows you to enable or disable the ASUS Hyper Path 2 feature Configuration options Disabled Enabled Auto Booting Graphic Priority Internal VGA Booting Graphic Priority Internal VGA Booting Graphic Priority Internal VGA Booting Graphic Priority Internal VGA Booting Graphic Priority Internal VGA Allows selection of the graphics controller to use as ...

Page 97: ...4 2E8 IRQ3 Parallel Port Address 378 Parallel Port Address 378 Parallel Port Address 378 Parallel Port Address 378 Parallel Port Address 378 Allows you to select the Parallel Port base addresses Configuration options Disabled 378 278 3BC Parallel Port Mode ECP Parallel Port Mode ECP Parallel Port Mode ECP Parallel Port Mode ECP Parallel Port Mode ECP Allows you to select the Parallel Port mode Con...

Page 98: ... Device IRQ 9 assigned to PCI Device IRQ 10 assigned to PCI Device IRQ 11 assigned to PCI Device IRQ 14 assigned to PCI Device IRQ 15 assigned to PCI Device Plug and Play O S No Plug and Play O S No Plug and Play O S No Plug and Play O S No Plug and Play O S No When set to No BIOS configures all the devices in the system When set to Yes and if you install a Plug and Play operating system the opera...

Page 99: ...ned to PCI Device IRQ xx assigned to PCI Device IRQ xx assigned to PCI Device IRQ xx assigned to PCI Device IRQ xx assigned to PCI Device When set to PCI Device the specific IRQ is free for use of PCI PnP devices When set to Reserved the IRQ is reserved for legacy ISA devices Configuration options PCI Device Reserved Reserved Memory Size Disabled Reserved Memory Size Disabled Reserved Memory Size ...

Page 100: ...1 5 5 1 5 5 1 5 5 1 5 5 1 ACPI APIC Support Enabled ACPI APIC Support Enabled ACPI APIC Support Enabled ACPI APIC Support Enabled ACPI APIC Support Enabled Allows you to enable or disable the Advanced Configuration and Power Interface ACPI support in the Advanced Programmable Interrupt Controller APIC When set to Enabled the ACPI APIC table pointer is included in the RSDT pointer list Configuratio...

Page 101: ...ameter allows you to turn on the system through a PCI LAN or modem card This feature requires an ATX power supply that provides at least 1A on the 5VSB lead Configuration options Disabled Enabled Power On By PS 2 Keyboard Disabled Power On By PS 2 Keyboard Disabled Power On By PS 2 Keyboard Disabled Power On By PS 2 Keyboard Disabled Power On By PS 2 Keyboard Disabled Allows you to use specific ke...

Page 102: ...peed xxxxRPM or N A Front1 Front2 Fan Speed xxxxRPM or N A Front1 Front2 Fan Speed xxxxRPM or N A Front1 Front2 Fan Speed xxxxRPM or N A Front1 Front2 Fan Speed xxxxRPM or N A Front1 Front2 Fan Speed xxxxRPM or N A Rear1 Rear2 Fan Speed xxxxRPM or N A Rear1 Rear2 Fan Speed xxxxRPM or N A Rear1 Rear2 Fan Speed xxxxRPM or N A Rear1 Rear2 Fan Speed xxxxRPM or N A Rear1 Rear2 Fan Speed xxxxRPM or N A ...

Page 103: ...appears on the screen depends on the number of devices installed in the system Configuration options xxxxx Drive Disabled Boot Device Priority 1st Boot Device 1st FLOPPY DRIVE 2nd Boot Device PM ST320410A 3rd Boot Device PS ASUS CD S520 A Specifies the Boot Device Boot Priority sequence Specifies the boot sequence from the availabe devices Hard Disk Drives 1st Drive 3M ST3800 3AS 2nd Drive 4M HDS7...

Page 104: ...rms all the POST items Configuration options Disabled Enabled Full Screen Logo Enabled Full Screen Logo Enabled Full Screen Logo Enabled Full Screen Logo Enabled Full Screen Logo Enabled This allows you to enable or disable the full screen logo display feature Configuration options Disabled Enabled Add On ROM Display Mode Force BIOS Add On ROM Display Mode Force BIOS Add On ROM Display Mode Force ...

Page 105: ...nstalled User Password Not Installed Change Supervisor Pas sword Boot Sector Virus Protection Disabled Enter to change password Enter again to disabled password Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Select this item to set or change the supervisor password The Supervisor Password item on top of the scr...

Page 106: ...l Access allows viewing and changing all the fields in the Setup utility Change User Password Change User Password Change User Password Change User Password Change User Password Select this item to set or change the user password The User Password item on top of the screen shows the default Not Installed Not Installed Not Installed Not Installed Not Installed After you set a password this item sho...

Page 107: ... both when accessing Setup and booting the system Configuration options Setup Always Boot Sector Virus Protection Disabled Boot Sector Virus Protection Disabled Boot Sector Virus Protection Disabled Boot Sector Virus Protection Disabled Boot Sector Virus Protection Disabled Allows you to enable or disable the boot sector virus protection Configuration options Disabled Enabled 5 7 Exit menu Pressin...

Page 108: ...efaults Load Setup Defaults Load Setup Defaults This option allows you to load the default values for each of the parameters on the Setup menus When you select this option or if you press F5 a confirmation window appears Select Y e s Y e s Y e s Y e s Y e s to load default values Select Exit Save Changes Exit Save Changes Exit Save Changes Exit Save Changes Exit Save Changes or make other changes ...

Page 109: ... E2 ASUS TS15 E2 ASUS TS15 E2 ASUS TS15 E2 ASUS TS15 E2 This chapter provides information on RAID configurations RAID driver installation and LAN driver installation for this motherboard Chapter 6 RAID configuration ...

Page 110: ... the data in the other drive This RAID configuration provides data protection and increases fault tolerance to the entire system Use two new drives or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive JBOD JBOD JBOD JBOD JBOD Spanning stands for Just a Bunch of Disks Just a Bunch of Disks Just a Bunch of Disks Just a Bunch...

Page 111: ...ration IDE Configuration IDE Configuration IDE Configuration then press Enter 3 Select the item Configure SATA As Configure SATA As Configure SATA As Configure SATA As Configure SATA As then press Enter to display the configuration options 4 Select RAID RAID RAID RAID RAID from the Configure SATA As Configure SATA As Configure SATA As Configure SATA As Configure SATA As item options then press Ent...

Page 112: ... enter the Intel Application Accelerator RAID Option ROM utility 1 Turn on the system after installing all the SATA hard disk drives 2 During POST press Ctrl I to display the utility main menu DISK VOLUME INFORMATION RAID Volumes None defined Non RAID Disks Port Drive Model Serial Size Type Status Vol ID 0 ST380013AS xxxxxxxx 74 5GB Non RAID Disk 1 ST380013AS xxxxxxxx 74 5GB Non RAID Disk Intel R ...

Page 113: ...r Select 2 Enter a name for the RAID 0 set then press Enter 3 Use the up or down arrow keys to move to the RAID Level RAID Level RAID Level RAID Level RAID Level item 4 When the RAID Level RAID Level RAID Level RAID Level RAID Level item is highlighted press the up or down arrow key to select RAID 0 RAID 0 RAID 0 RAID 0 RAID 0 then press Enter 5 Use the up or down arrow keys to move to the Stripe ...

Page 114: ...right C 2003 04 Intel Corporation All Rights Reserved CREATE ARRAY MENU Name RAID_Volume1 RAID Level RAID1 Mirror Disks Select Disk Strip Size 128KB Capacity 149 0GB Change Change TAB Next TAB Next ESC Previous Menu ESC Previous Menu Enter Select Enter Select 2 Enter a name for the RAID 1 set then press Enter 3 Use the up or down arrow keys to move to the RAID Level RAID Level RAID Level RAID Leve...

Page 115: ...ember disks to become available as non RAID disks WARNING EXISTING DATA WITHIN THIS VOLUME WILL BE LOST AND NON RECOVERABLE Intel R Application Accelerator RAID Option ROM v4 0 0 6211 Copyright C 2003 04 Intel Corporation All Rights Reserved DELETE ARRAY MENU Select Select ESC Previous Menu ESC Previous Menu DEL Delete Volume DEL Delete Volume Name Level Drives Capacity Status Bootable RAID_Volume...

Page 116: ...sks to Non RAID 3 Reset Disks to Non RAID 3 Reset Disks to Non RAID then press Enter to display the following screen Resetting RAID data will remove the internal RAID structures from the selected RAID disks By removing these structures the drive will revert back to a Non RAID disk RESET RAID DATA WARNING Resetting a disk causes all data on the disk to be lost Port Drive Model Serial Size Status 0 ...

Page 117: ...DOS environment 1 Place the motherboard support CD in the optical drive 2 Restart the computer then enter the BIOS Setup 3 Set the optical drive as the first boot priority to boot from the support CD Save your changes then exit the BIOS Setup 4 Restart the computer The following screen appears during POST 6 Press any key to continue The RAID drivers are copied to the floppy disk 7 Eject the floppy...

Page 118: ...hard disk drive then place the system motherboard support CD in the optical drive 2 Browse the contents of the support CD to locate the driver disk utility The RAID driver disk for the Intel ICH6R is located in Drivers Chipset Intel IAA F6 Install Floppy F6flpy32 Drivers Chipset Intel IAA F6 Install Floppy F6flpy32 Drivers Chipset Intel IAA F6 Install Floppy F6flpy32 Drivers Chipset Intel IAA F6 I...

Page 119: ...tallation To install the Intel ICH6R RAID controller driver when installing Windows 2000 2003 Server OS 1 Boot the computer using the Windows 2000 2003 Server installation CD The Windows Windows Windows Windows Windows 2000 2003 Setup 2000 2003 Setup 2000 2003 Setup 2000 2003 Setup 2000 2003 Setup starts 2 Press F6 when the message Press F6 if you need to install Press F6 if you need to install Pr...

Page 120: ... disk drive then press Enter 5 Select the Intel R 82801FR SATA RAID Controller Desktop Intel R 82801FR SATA RAID Controller Desktop Intel R 82801FR SATA RAID Controller Desktop Intel R 82801FR SATA RAID Controller Desktop Intel R 82801FR SATA RAID Controller Desktop ICH6R ICH6R ICH6R ICH6R ICH6R from the options then press Enter to select 6 The Windows 2000 2003 Setup loads the RAID controller dri...

Page 121: ...iver for my device recommended recommended recommended recommended recommended then click Next Next Next Next Next 10 The wizard searches the RAID controller drivers When found click Next Next Next Next Next to install the drivers To an existing Windows 2000 2003 Server OS To install the Intel ICH6R RAID controller driver on an existing Windows 2000 2003 Server OS 1 Restart the computer then log o...

Page 122: ...re the item IDE ATA ATAPI controllers IDE ATA ATAPI controllers IDE ATA ATAPI controllers IDE ATA ATAPI controllers IDE ATA ATAPI controllers The Intel R 82801FB Ultra ATA Storage Controllers 2652 Intel R 82801FB Ultra ATA Storage Controllers 2652 Intel R 82801FB Ultra ATA Storage Controllers 2652 Intel R 82801FB Ultra ATA Storage Controllers 2652 Intel R 82801FB Ultra ATA Storage Controllers 2652...

Page 123: ...d system support CD to the optical drive The CD automatically displays the Drivers Drivers Drivers Drivers Drivers menu if Autorun is enabled in your computer Windows automatically detects the LAN controllers and displays a New Hardware Found New Hardware Found New Hardware Found New Hardware Found New Hardware Found window Click Cancel Cancel Cancel Cancel Cancel to close this window If Autorun A...

Page 124: ...pter 6 RAID configuration and driver installation Chapter 6 RAID configuration and driver installation Chapter 6 RAID configuration and driver installation 6 16 6 16 6 16 6 16 6 16 4 Click Next Next Next Next Next when the InstallShield Wizard window appears Follow screen instructions to continue installation ...

Page 125: ...O K 12 Restart the computer when prompted 6 3 2 6 3 2 6 3 2 6 3 2 6 3 2 Windows Windows Windows Windows Windows N T N T N T N T N T You must install a network device driver before you can use the LAN adapter on a Windows NT system You must upgrade the system to Windows NT Service Pack 4 or later before you install the LAN adapter drivers BACS2 Help files require Internet Explorer 4 0 or later to w...

Page 126: ...dhat OpenLinux turbo packages rpm rpm bb SPECS bcm5700 spec or rpmbuild bb SPECS bcm5700 spec The RPM path is different for different Linux distributions 3 Install the newly built package driver and man page rpm ivh RPMS i386 bcm5700 version i386 rpm You need the force option when installing the driver on some distributions that has an older version of the driver For 2 2 x kernels 2 2 x kernels 2 ...

Page 127: ... build the driver from the TAR file 1 Create a directory and extract the TAR files tar xvzf bcm5700 version tar gz 2 Build the driver bcm5700 o as a loadable module for the running kernel cd bcm5700 version src make 3 Test the driver by loading it insmod bcm5700 o 4 Install the driver and man page make install See the RPM instructions on the previous page for the location of the installed driver 5...

Page 128: ...ator privileges 2 Insert the motherboard system support CD to the optical drive The support CD automatically displays the Drivers Drivers Drivers Drivers Drivers menu if Autorun is enabled in your computer Windows automatically detects the VGA controller and displays a N e w N e w N e w N e w N e w Hardware Found Hardware Found Hardware Found Hardware Found Hardware Found window Click Cancel Cance...

Page 129: ...erties Properties from the menu 2 Click the Hardware Hardware Hardware Hardware Hardware tab then click the Device Manager Device Manager Device Manager Device Manager Device Manager button 3 Click the sign before the item Display adapters Display adapters Display adapters Display adapters Display adapters The Intel R E7221 Integrated Graphics Controller Intel R E7221 Integrated Graphics Controlle...

Page 130: ...on Chapter 6 RAID configuration and driver installation 6 22 6 22 6 22 6 22 6 22 6 4 3 6 4 3 6 4 3 6 4 3 6 4 3 Red Hat Red Hat Red Hat Red Hat Red Hat Linux 9 0 Linux 9 0 Linux 9 0 Linux 9 0 Linux 9 0 The Red Hat Linux 9 0 2 4 x kernels operating system automatically recognizes the Intel E7221 SVGA driver during system installation There is no need to install an additional driver s to support the ...

Page 131: ...SUS TS150 E2 This appendix gives information on the standard and redundant power supply that came with the barebone server This section also provides a troubleshooting guide for solving common problems when using the barebone server Appendix Reference information ...

Page 132: ...ork work work Check if the keyboard cable is properly connected to the PS 2 keyboard port The mouse does not work The mouse does not work The mouse does not work The mouse does not work The mouse does not work Check if the mouse cable is properly connected to the mouse port The system does not The system does not The system does not The system does not The system does not perform power on self per...

Page 133: ...Make sure that the DIMMs are properly installed on the sockets The message Non system The message Non system The message Non system The message Non system The message Non system disk or disk error disk or disk error disk or disk error disk or disk error disk or disk error appears appears appears appears appears 1 Check if a bootable HDD is active 2 Check if the HDDs are properly installed Network ...

Page 134: ...5 50 mV 12V2 0 0 A 18 A 11 4 12 6 120 mV A 2 Power supply specification A 2 1 A 2 1 A 2 1 A 2 1 A 2 1 Input characteristics Input characteristics Input characteristics Input characteristics Input characteristics Voltage Range Voltage Range Voltage Range Voltage Range Voltage Range 2 3 0 V 2 3 0 V 2 3 0 V 2 3 0 V 2 3 0 V Parameter Parameter Parameter Parameter Parameter M i n M i n M i n M i n M i ...

Reviews: