background image

 

 

 

 

Last Updated: January 30, 2019

 

 

BOXER-6405U 

 

Fanless  Embedded  Box  PC 

 

User’s  Manual  2

nd

  Ed

Summary of Contents for AAEON BOXER-6405U

Page 1: ...Last Updated January 30 2019 BOXER 6405U Fanless Embedded Box PC User s Manual 2nd Ed ...

Page 2: ...ded in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to a...

Page 3: ... registered trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Atom is a trademark of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Page 4: ...up your product please make sure the following items have been shipped Item Quantity BOXER 6405U 1 2 Pin DC In Power Connector 1 Wallmount bracket 2 Screw Package 1 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ... as detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the AAEON com for the latest version of this document ...

Page 6: ... the system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disconnect it from the power supply to avoid damage by transient over voltage 8 Always disconnect this device from any AC supply before cleaning 9 While cleaning use a damp cloth instead of liquid or...

Page 7: ...ainers 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 19 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED EN...

Page 8: ... explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalent...

Page 9: ...ded Box PC Industrial System 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 电源 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 电源为选购品 ...

Page 10: ...nyl Ethers PBDE PCB Other Components Wires Connectors for External Connections Chassis CPU RAM Hard Disk PSU O The quantity of poisonous or hazardous substances or elements found in each of the component s parts is below the SJ T 11363 2006 stipulated requirement X The quantity of poisonous or hazardous substances or elements found in at least one of the component s parts is beyond the SJ T 11363 ...

Page 11: ...M Port 1 Wafer Box Optional CN5 10 2 4 2 COM Port 2 Wafer Box Optional CN6 10 2 4 3 Mini Card Slot Half Mini Card CN7 11 2 4 4 Mini Card Slot Full Mini Card CN8 13 2 4 5 SATA Port CN13 16 2 4 6 5V Output for SATA HDD 2P Pitch 2 0mm CN16 16 2 4 7 HDMI Connector CN18 17 2 4 8 DC IN CONNECTOR 2P CN23 18 2 4 9 LAN RJ 45 USB3 0 CN27 18 2 4 10 DUAL USB3 0 CN28 19 2 4 11 LAN RJ 45 USB3 0 CN29 20 2 5 Wall...

Page 12: ...ort 2 Configuration 36 3 4 6 Power Management 37 3 5 Setup submenu Chipset 38 3 5 1 Chipset North Bridge 39 3 5 2 Chipset South Bridge 40 3 6 Setup submenu Security 41 3 6 1 Secure Boot 42 3 6 2 Key management 43 3 7 Setup submenu Boot 47 3 8 Setup submenu Save Exit 48 Chapter 4 Drivers Installation 49 4 1 Driver Installation 50 Appendix A Watchdog Timer Programming 52 A 1 Watchdog Timer Initial P...

Page 13: ...Fanless Embedded Box PC BOXER 6405U Chapter 1 Chapter 1 Product Specifications ...

Page 14: ...ice 16 or 32G eMMC On board Ethernet RJ 45 x 2 for 10 100 1000 base T Intel i211 I O LAN x 2 USB 3 0 x 4 HDMI x 1 DB9 x 2 for RS 232 2 pin 9 24V DC Power Input x 1 Power Button x 1 Expansion Full size Minicard x 1 PCIe USB Half size Minicard x 1 PCIe USB Optional for mSATA Indicator Power LED on Power Button OS Support Windows 10 Windows 10 IoT Linux Ubuntu16 04 4 Power Supply Power Requirement 9 ...

Page 15: ... 6mm D Gross Weight 3 6 lb 1 6kg Net Weight 1 76 lb 0 8 kg Environmental Operating Temperature 20 C 50 C with W T SSD HDD mSATA according to IEC68 2 14 with 0 5 m s AirFlow with industrial devices Storage Temperature 40 F 158 F 40 C 70 C Storage Humidity 95 40 C non condensing Anti Vibration 3 Grms 5 500Hz operation Certification CE FCC class A ...

Page 16: ...Fanless Embedded Box PC BOXER 6405U Chapter 2 Chapter 2 Hardware Information ...

Page 17: ...Chapter 2 Hardware Information 5 Fanless Embedded Box PC BOXER 6405U 2 1 Dimensions BOXER 6405U ...

Page 18: ...Chapter 2 Hardware Information 6 Fanless Embedded Box PC BOXER 6405U 2 2 Jumpers and connectors ...

Page 19: ...al pins and a small metal clip often protected by a plastic cover that slides over the pins to connect them To close a jumper you connect the pins with the clip To open a jumper you remove the clip Sometimes a jumper will have three pins labeled 1 2 and 3 In this case you would connect either pins 1 and 2 or 2 and 3 1 2 3 Open Closed Closed 2 3 A pair of needle nose pliers may be helpful when work...

Page 20: ...wer Button Selection JP1 ATX Default AT JP1 Function 1 2 ATX Default 2 3 AT Disable Auto Power Button JP1 1 2 Need to use power button JP1 1 2 to power on the system 2 3 3 Clear CMOS JP2 Normal Default Clear CMOS JP2 Function 1 2 Normal Default 2 3 Clear CMOS 1 2 3 1 2 3 1 2 3 1 2 3 ...

Page 21: ...r all of the system s connectors that you can configure for your application Label Function CN5 COM1 RS232 CN6 COM2 RS232 CN7 Mini PCIE slot CN8 Mini PCIE slot CN13 SATA1 CN16 SATA PWR Connector CN18 HDMI Connector CN23 Phoenix connector Power input CN27 LAN USB3 0 Connector CN28 Dual USB3 0 Connector CN29 LAN USB3 0 Connector ...

Page 22: ...fer Box Optional CN5 Pin Pin Name Signal Type Signal Level 1 DCD1 IN 2 DSR1 IN 3 RX1 IN 4 RTS1 OUT 9V 5 TX1 OUT 9V 6 CTS1 IN 7 DTR1 OUT 9V 8 RI1 IN 9 GND GND 2 4 2 COM Port 2 Wafer Box Optional CN6 Pin Pin Name Signal Type Signal Level 1 DCD2 IN 2 DSR2 IN 3 RX2 IN 4 RTS2 OUT 9V 5 TX2 OUT 9V ...

Page 23: ...l Level 6 CTS2 IN 7 DTR2 OUT 9V 8 RI2 IN 9 GND GND 2 4 3 Mini Card Slot Half Mini Card CN7 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3V PWR 3 3V 3 NC 4 GND GND 5 NC 6 1 5V PWR 1 5V 7 PCIE_CLK_REQ IN 8 NC PWR 9 GND GND 10 NC I O 11 PCIE_REF_CLK DIFF 12 NC IN 13 PCIE_REF_CLK DIFF 14 NC IN ...

Page 24: ... 18 GND GND 19 NC 20 W_DISABLE OUT 3 3V 21 GND GND 22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_TX DIFF 32 SMB_DATA I O 3 3V 33 PCIE_TX DIFF 34 GND GND 35 GND GND 36 USB_D DIFF 37 GND GND 38 USB_D DIFF 39 3 3VSB PWR 3 3V 40 GND GND ...

Page 25: ...Pin Name Signal Type Signal Level 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC 45 NC 46 NC 47 NC 48 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V 2 4 4 Mini Card Slot Full Mini Card CN8 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3V PWR 3 3V 3 NC 4 GND GND ...

Page 26: ...5V 7 PCIE_CLK_REQ IN 8 NC PWR 9 GND GND 10 NC I O 11 PCIE_REF_CLK DIFF 12 NC IN 13 PCIE_REF_CLK DIFF 14 NC IN 15 GND GND 16 NC PWR 17 NC 18 GND GND 19 NC 20 W_DISABLE OUT 3 3V 21 GND GND 22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V ...

Page 27: ...ignal Type Signal Level 31 PCIE_TX DIFF 32 SMB_DATA I O 3 3V 33 PCIE_TX DIFF 34 GND GND 35 GND GND 36 USB_D DIFF 37 GND GND 38 USB_D DIFF 39 3 3VSB PWR 3 3V 40 GND GND 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC 45 NC 46 NC 47 NC 48 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V ...

Page 28: ...5U 2 4 5 SATA Port CN13 Pin Pin Name Signal Type Signal Level 1 GND GND 2 SATA_TX DIFF 3 SATA_TX DIFF 4 GND GND 5 SATA_RX DIFF 6 SATA_RX DIFF 7 GND GND 2 4 6 5V Output for SATA HDD 2P Pitch 2 0mm CN16 Pin Pin Name Signal Type Signal Level 1 5V PWR 2 GND GND Pin 1 Pin 7 ...

Page 29: ...Signal Level 1 HDMI_1_DATA2_P OUT 2 GND GND 3 HDMI_1_DATA2_N DIFF 4 HDMI_1_DATA1_P DIFF 5 GND GND 6 HDMI_1_DATA1_N DIFF 7 HDMI_1_DATA0_P DIFF 8 NC 9 HDMI_1_DATA0_N DIFF 10 HDMI_1_CLK_C_P DIFF 11 GND GND 12 HDMI_1_CLK_C_N DIFF 13 NC 14 NC 15 HDMI_1_SCL I O 16 HDMI_1_SDA I O 17 GND GND 18 V5S_HDMI_1_CON GND 19 HDMI_1_HPD IN ...

Page 30: ...R 6405U 2 4 8 DC IN CONNECTOR 2P CN23 Pin Pin Name Signal Type Signal Level 1 VIN PWR 9V 24V 2 GND GND 2 4 9 LAN RJ 45 USB3 0 CN27 Pin Pin Name Signal Type Signal Level 1 MDI0 DIFF 2 MDI0 DIFF 3 MDI1 DIFF 4 MDI2 DIFF 5 MDI2 DIFF 6 MDI1 DIFF 7 MDI3 DIFF 8 MDI3 DIFF ...

Page 31: ... Type Signal Level U1 5VSB PWR 5V U2 USB0_D DIFF U3 USB0_D DIFF U4 GND GND U5 USB0_SSRX DIFF U6 USB0_SSRX DIFF U7 GND GND U8 USB0_SSTX DIFF U9 USB0_SSTX DIFF 2 4 10DUAL USB3 0 CN28 Pin Pin Name Signal Type Signal Level 1 5VSB PWR 5V 10 Port 1 Port 0 11 12 13 1 2 3 4 14 15 16 17 18 5 6 7 8 9 ...

Page 32: ...Signal Level 2 USB0_D DIFF 3 USB0_D DIFF 4 GND GND 5 USB0_SSRX DIFF 6 USB0_SSRX DIFF 7 GND GND 8 USB0_SSTX DIFF 9 USB0_SSTX DIFF 10 5VSB PWR 5V 11 USB1_D DIFF 12 USB1_D DIFF 13 GND GND 14 USB1_SSRX DIFF 15 USB1_SSRX DIFF 16 GND GND 17 USB1_SSTX DIFF 18 USB1_SSTX DIFF 2 4 11 LAN RJ 45 USB3 0 CN29 ...

Page 33: ...Embedded Box PC BOXER 6405U Pin Pin Name Signal Type Signal Level 1 MDI0 DIFF 2 MDI0 DIFF 3 MDI1 DIFF 4 MDI2 DIFF 5 MDI2 DIFF 6 MDI1 DIFF 7 MDI3 DIFF 8 MDI3 DIFF Pin Pin Name Signal Type Signal Level U1 5VSB PWR 5V U2 USB0_D DIFF U3 USB0_D DIFF ...

Page 34: ...ox PC BOXER 6405U Pin Pin Name Signal Type Signal Level U4 GND GND U5 USB0_SSRX DIFF U6 USB0_SSRX DIFF U7 GND GND U8 USB0_SSTX DIFF U9 USB0_SSTX DIFF 2 5 Wall mount bracket installation Attach the wall mount bracket onto the chassis and secure the screws ...

Page 35: ...Fanless Embedded Box PC BOXER 6405U Chapter 3 Chapter 3 AMI BIOS Setup ...

Page 36: ...es check the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS settings You are starting your system for the first time You have changed your syst...

Page 37: ...d when the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date elements Advanced Enable Disable boot option for legacy network devices Chipset For hosting bridge parameters Boot Enable Disable quiet Boot Option Security The setup ...

Page 38: ...Chapter 3 AMI BIOS Setup 26 Fanless Embedded Box PC BOXER 6405U 3 3 Setup Submenu Main ...

Page 39: ...Chapter 3 AMI BIOS Setup 27 Fanless Embedded Box PC BOXER 6405U 3 4 Setup Submenu Advanced ...

Page 40: ...C BOXER 6405U 3 4 1 Advanced Trusted Computing Options summary Security Device Support Disabled Enabled Optimal Default Failsafe Default Enable Disable Security Device NOTE Your Computer will reboot during restart in order to change State of the Device ...

Page 41: ...Chapter 3 AMI BIOS Setup 29 Fanless Embedded Box PC BOXER 6405U 3 4 2 Advanced CPU Configuration ...

Page 42: ... Enabled Optimal Default Failsafe Default When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology VT d Disabled Enabled Optimal Default Failsafe Default Enable Disable CPU VT d EIST Disabled Enabled Optimal Default Failsafe Default Enable Disable Intel SpeedStep Turbo Mode Disabled Enabled Optimal Default Failsafe Default Turbo Mode Boot performance Ma...

Page 43: ...de Max battery Select the performance state that the BIOS will set before OS handoff Power Limit 1 Enable Disabled Optimal Default Failsafe Default Enabled Enable Disable Power Limit 1 C States Disabled Optimal Default Failsafe Default Enabled Enable Disable C States ...

Page 44: ...fault Failsafe Default Disable Enable or Disable the Chipset SATA Controller The Chipset SATA controller supports the 2 black internal SATA ports up to 3Gb s supported per port Port Enable Optimal Default Failsafe Default Disable Enable or Disable SATA Port Port Enable Optimal Default Failsafe Default Disable Enable or Disable SATA Port ...

Page 45: ...Chapter 3 AMI BIOS Setup 33 Fanless Embedded Box PC BOXER 6405U 3 4 4 Advanced Hardware Monitor ...

Page 46: ...Chapter 3 AMI BIOS Setup 34 Fanless Embedded Box PC BOXER 6405U 3 4 5 Advanced SIO Configuration ...

Page 47: ...ummary Use This Device Disabled Enabled Optimal Default Failsafe Default Enable or Disable this Logical Device Possible Use Automatic Settings Optimal Default Failsafe Default IO 3F8 IRQ 4 IO 2F8 IRQ 3 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 48: ...ummary Use This Device Disabled Enabled Optimal Default Failsafe Default Enable or Disable this Logical Device Possible Use Automatic Settings Optimal Default Failsafe Default IO 2F8 IRQ 3 IO 3F8 IRQ 4 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 49: ...fault Failsafe Default AT Type Select system power mode Restore AC Power Loss Last State Optimal Default Failsafe Default Always On Always Off RTC wake system from S5 Disabled Optimal Default Failsafe Default Fixed Time Dynamic Time Enable or disable System wake on alarm event When enabled System will wake on the hr min sec specified ...

Page 50: ...Chapter 3 AMI BIOS Setup 38 Fanless Embedded Box PC BOXER 6405U 3 5 Setup submenu Chipset ...

Page 51: ...39 Fanless Embedded Box PC BOXER 6405U 3 5 1 Chipset North Bridge Options summary DCMT Total Gfx Mem 128M Optimal Default Failsafe Default 256M MAX Select DVMT5 0 Total Graphics Memory size used by the Internal Graphics Device ...

Page 52: ...lt Failsafe Default Enable Enable Disable HD Audio Support Full Mini Card Speed Auto Optimal Default Failsafe Default Gen 1 Gen 2 Configure PCIe Speed Half Mini Card Speed Auto Optimal Default Failsafe Default Gen 1 Gen 2 Configure PCIe Speed SCC eMMC Support Disable Enable Optimal Default Failsafe Default Enable Disable SCC eMMC Support Support ...

Page 53: ...t provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or numbers Press Enter to confirm your entry after which you will be prompted to retype your password for a final confirmation Press Enter again after you have retyped it correctly Removing the Password High...

Page 54: ...ble Secure Boot activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Secure Boot Mode Standard Optimal Default Failsafe Default Customized Secure Boot Mode Custom Standard Set UEFI Secure Boot Mode to STANDARD mode or CUSTOM mode this change is effect after save And after reset the mode will return to STANDARD mode ...

Page 55: ...es without full authentication Options summary Provision Factory Default keys Disable Optimal Default Failsafe Default Enable Allow to provision factory default Secure Boot keys when System is in Setup Mode Install Factory Default Keys No Press Yes to install factory default keys Yes Force System to User Mode install all Factory Default keys ...

Page 56: ...r Secure UpCase Volume System Volume Information Extend Acpi a0341d0 0 PCI 12 0 DevicePath Type 3 SubType 18 HD Part2 Sig EFI dbx Acpi a0341d0 0 PCI 12 0 DevicePath Type 3 SubType 18 HD Part4 Sig AttrDef BadClus Bitmap Boot LogFile MFT MFTMirr Secure UpCase Volume Hiberfil sys Pagefile sys Swapfile sys Windows Users System Volume Information Recovery ProgramData Program Files x86 Program Files Per...

Page 57: ...ile system device Secure Boot variable Size Keys key Source Platform key PK 0 0 No Key Set New Var No Press Yes to load factory default PK or Select No to load it from a File on external media Yes Key Exchange keys 0 0 No Key Set New Var No Press Yes to load factory default KEK or Select No to load it from a File on external media Yes Append Key No Press Yes to load factory default KEK or Select N...

Page 58: ...oad factory default dbt or Select No to load it from a File on external media Yes Append Key No Press Yes to load factory default dbt or Select No to load it from a File on external media OsRecovery Signatures 0 0 No Key Set New Var No Press Yes to load factory default dbr or Select No to load it from a File on external media Yes Append Key No Press Yes to load factory default dbr or Select No to ...

Page 59: ... PC BOXER 6405U 3 7 Setup submenu Boot Options summary Quiet Boot Disabled Enabled Optimal Default Failsafe Default Enable or Disable Quiet Boot option Network Stack Disabled Optimal Default Failsafe Default Enabled Enable Disable UEFI Network Stack ...

Page 60: ...Chapter 3 AMI BIOS Setup 48 Fanless Embedded Box PC BOXER 6405U 3 8 Setup submenu Save Exit ...

Page 61: ...Fanless Embedded Box PC BOXER 6405U Chapter 4 Chapter 4 Drivers Installation ...

Page 62: ... 4 Drivers will be installed automatically Step 2 Install Graphics Driver 1 Open the Step 2 Graphics folder and select your OS 2 Open the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 3 Install TXE Driver 1 Open the Step 3 TXE folder and select your OS 2 Open the SetupTXE exe file 3 Follow the instructions 4 Drivers will be installed automati...

Page 63: ...ons 4 Drivers will be installed automatically Step 6 Install Serial IO Drivers 1 Open the Step 6 Serial IO Driver folder and select your OS 2 Open the SetupSerialIO exe file 3 Follow the instructions 4 Drivers will be installed automatically Step 7 Install Serial Port Driver Optional 1 Open the Step 7 Serial Port Driver Optional folder and select your OS 2 Open the FintekSerial exe file in the fol...

Page 64: ...Fanless Embedded Box PC BOXER 6405U Appendix A Appendix A Watchdog Timer Programming ...

Page 65: ...ue Note Timer Counter 0x07 Note3 0xF6 Note4 Note24 Time of watchdog timer 0 255 This register is byte access Counting Unit 0x07 Note5 0xF5 Note6 3 Note7 0 Note8 Select time unit 0 second 1 minute Watchdog Enable 0x07 Note9 0xF5 Note10 5 Note11 1 Note12 0 Disable 1 Enable Timeout Status 0x07 Note13 0xF5 Note14 6 Note15 1 1 Clear timeout status Output Mode 0x07 Note16 0xF5 Note17 4 Note18 1 Note19 S...

Page 66: ...yte UnitVal This parameter is represented from Note8 define byte EnableLDN This parameter is represented from Note9 define byte EnableReg This parameter is represented from Note10 define byte EnableBit This parameter is represented from Note11 define byte EnableVal This parameter is represented from Note12 define byte StatusLDN This parameter is represented from Note13 define byte StatusReg This p...

Page 67: ... Embedded Box PC BOXER 6405U VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure will enable the WDT counting AaeonWDTEnable ...

Page 68: ...relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet LDN Register BitNum Value VOID WDTParameterSetting Watchdog Timer counter setting SIOByteSet TimerLDN TimerReg TimerVal WDT counting unit setting SIOBitSet UnitLDN UnitReg UnitBit UnitVal WDT output mode setting level pulse SIOBitSet ModeLDN ModeReg ModeBit ModeVal Watchdog ...

Page 69: ... Register Offset 0x07 IOWriteByte SIOData LDN VOID SIOBitSet byte LDN byte Register byte BitNum byte Value Byte TmpValue SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet byte LDN byte Register byte Value SIOEnterMBPnPMode SIOSelectLDN LDN IOWriteByt...

Page 70: ...Fanless Embedded Box PC BOXER 6405U Appendix B Appendix B I O Information ...

Page 71: ...Appendix B I O Information 59 Fanless Embedded Box PC BOXER 6405U B 1 I O Address Map ...

Page 72: ...Appendix B I O Information 60 Fanless Embedded Box PC BOXER 6405U B 2 Memory Address Map ...

Page 73: ...Appendix B I O Information 61 Fanless Embedded Box PC BOXER 6405U B 3 IRQ Mapping Chart ...

Page 74: ...Appendix B I O Information 62 Fanless Embedded Box PC BOXER 6405U ...

Page 75: ...Appendix B I O Information 63 Fanless Embedded Box PC BOXER 6405U ...

Page 76: ...Appendix B I O Information 64 Fanless Embedded Box PC BOXER 6405U ...

Page 77: ...Appendix B I O Information 65 Fanless Embedded Box PC BOXER 6405U ...

Page 78: ...Appendix B I O Information 66 Fanless Embedded Box PC BOXER 6405U ...

Page 79: ...Appendix B I O Information 67 Fanless Embedded Box PC BOXER 6405U ...

Page 80: ...Appendix B I O Information 68 Fanless Embedded Box PC BOXER 6405U ...

Page 81: ...Appendix B I O Information 69 Fanless Embedded Box PC BOXER 6405U ...

Reviews: