ASTROAI USER MANUAL 
TRUE RMS DIGITAL MULTIMETER

Thank you for purchasing the True RMS 6000 Count Digital Multimeter from AstroAI. The 
AstroAI True RMS Digital Multimeter is designed to be safely and accurately used by 
professionals in a commercial setting or weekend DYer’s that need a little more utility from their 
standard digital multimeter. This manual provides all safety information, operation instruction, 
specifications, and maintenance for the meter. The instrument performs AC/DC Voltage, AC/DC 
Current, Resistance, Audible Continuity, Diode, hFE, Frequency, Capacitance, and 
Temperature Testing. Thank you again for choosing AstroAI, if you have any questions or 
concerns regarding your product, please contact us at 

[email protected]

.

NOTE: 

Fully read and understand this manual before using this Digital Multimeter. 

WARNING

: To avoid possible electric shock or personal injury, and to avoid possible damage to 

the Meter or to the equipment being tested, adhere to the following rules:

Before using the Meter, inspect the exterior casing. Do not use the Meter if it is damaged 
or if all or part of the exterior casing is removed. Look for cracks or missing plastic. Pay 
special attention to the insulation around the connectors.

Inspect the test leads for damaged insulation or exposed metal. Check the test leads for 
continuity. 

Do not apply more than the rated voltage, as marked on the Meter, between the 
terminals or between any terminal and grounding. 

The manual rotary switch should be placed in the correct position before measurement 
and should NOT be moved during measurement to prevent damage to the Meter.

When the Meter is working at an effective voltage over 60V in DC or 30V rms in AC, 
special care should be taken because there is a danger of electric shock.

Use the proper terminals, function, and range for your measurements. 

Do not use or store the Meter in a high-temperature environment, do not expose to high 
levels of humidity, or near strong magnetic fields. The performance of the Meter may 
deteriorate after dampening.

When using the test leads, keep your fingers behind the finger guards.

Disconnect circuit power and discharge all high-voltage capacitors before testing 
resistance, continuity, diodes or hFE.

Replace the battery as soon as the battery indicator appears.  With a low battery, the 
Meter might produce false readings that can lead to electric shock and personal injury.

Remove the connection between the testing leads and the circuit being tested, and turn 
the Meter power off before opening the Meter case.

When servicing the Meter, use only the same model number or identical electrical 
specifications replacement parts.

The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter 
and any accident.

Summary of Contents for True RMS 6000

Page 1: ...xposed metal Check the test leads for continuity Do not apply more than the rated voltage as marked on the Meter between the terminals or between any terminal and grounding The manual rotary switch sh...

Page 2: ...en it has not been used for some time Replace the battery as soon as leaking appears A leaking battery will damage the Meter ELECTRICAL SYMBOLS AC Alternating Current Low Battery DC Direct Current Dio...

Page 3: ...requency Yes Safety Compliances EN 61010 1 CAT III 600V CATII 1000V DC Voltage 600mV6 0 8 5 V 60V 600V 0 8 3 1000V 1 5 AC Voltage 600mV 1 2 8 6V 60V 600V 1 2 6 750V 1 2 8 Temperature 40 C 1370 C 40 F...

Page 4: ...MULTIMETER DIAGRAM 1 Magnetic Hanger 2 LCD Screen 3 Function Buttons 4 Rotary Function Switch 5 10A Terminal 6 A mA Terminal 7 COM Terminal 8 INPUT Terminal 9 Silicone Sleeve 10 Multi Function Socket...

Page 5: ...elative Mode GETTING TO KNOW YOUR DEVICE Select Button When using the rotary switch to select a multimeter function use the Select Button to further select the function This applies only to multifunct...

Page 6: ...leads for example To activate this function simply press the Relative Button A small triangle delta symbol will appear on the display and the reading should change to zero Press the Relative Button a...

Page 7: ...ection 600V DC AC RMS Max Input voltage 600V DC Measure DCV 1000V under CATII AC Voltage Auto ranging Range Resolution Accuracy 600mV 0 1mV 1 2 of rdg 8dgts 6V 1mV 60V 10mV 1 2 of rdg 6dgts 600V 100mV...

Page 8: ...nge Resolution Accuracy 600 A 0 1 A 6000 A 1 A 60mA 10 A 600mA 100 A 0 8 of rdg 5dgts 6A 1mA 10A 10mA 1 5 of rdg 3dgts Overload Protection mA Jack F0 4A 600V fuse 10A Jack F10A 600V fuse Max Input Cur...

Page 9: ...6000 A 1 A 60mA 10 A 600mA 100 A 1 5 of rdg 8dgts 10A 100mA 2 0 of rdg 10dgts Overload Protection mA jack F0 4A 600V fuse 10A jack F10A 600V fuse Max Input Current mA jack 400mA 10A jack 10A For meas...

Page 10: ...A 2 5 10 200A 1mV 1A Diode and Continuity Range Introduction Remark The approximate forward voltage drop will be displayed Open circuit voltage about 1 5V The built in buzzer will sound if the resista...

Page 11: ...UT jack 2 Set the function switch to V or V range Choose either Auto or Manual range using the Range Button 3 In manual range if the voltage magnitude to be measured is unknown beforehand select the h...

Page 12: ...ce Measurement 1 Connect the black test lead to the COM jack and the red test lead to the INPUT jack 2 Set the function switch to range 3 Select either Auto or Manual range with the Range button In ma...

Page 13: ...socket of the adapter 4 Read the LCD display for the approximate hFE value Temperature Measurement 1 Set the function switch to C F range 2 Use the Select Button to choose either Celsius or Fahrenhei...

Page 14: ...clamp 5 The results will be displayed on the LCD display Note a Each time a measurement is taken make sure that only one cable is clamped and is in the center of the clamp jaws b The clamp can only t...

Page 15: ...ion Socket DISPOSAL OF THIS ARTICLE If you at some point intend to dispose of this article please keep in mind that many of its components consist of valuable materials which can be recycled Please do...

Reviews: