background image

29/01/2015 

 

 

 

 

 

 

 

INSTALLATION AND 

OPERATING INSTRUCTIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Melbourne: 03 8796 8600 

Gold Coast: 07 5552 2600 

Perth: 08 9350 2600 

Sydney Nth:  02 9853 2100 

Sydney Sth: 02 8778 9500 

Townsville: 07 4796 0100 

Brisbane: 07 3308 5400  

Adelaide: 08 8152 7600  

www.astralpool.com.au 

 

 

 

 

 

 

 

 

[email protected]

 

Bolero ND 

Cleaner 

INSTALLATION AND OPERATING INSTRUCTIONS 

INSTALLATION AND OPERATING INSTRUCTIONS 

 RX Series & E Series 
 Sand Filters

 

 

Summary of Contents for RX 280

Page 1: ...08 9350 2600 Sydney Nth 02 9853 2100 Sydney Sth 02 8778 9500 Townsville 07 4796 0100 Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au sales astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS RX Series E Series Sand Filters ...

Page 2: ...0ltrs 192 000ltrs 125 kg 175 kg 200 kg Dimensions With Valve Installed Model Height Width Shipping Weight RX 280 RX 360 RX 400 105 cm 106 cm 114 cm 61 cm 70 cm 76 cm 22 kg 32 kg 38 kg Model No Tank Diameter Filter Area Port Size 6 Hr Turnover 8 Hr Turnover Media Req d Eco 550 Eco 650 Eco 750 550 mm 650 mm 750 mm 0 20 Sq M 0 33 Sq M 0 42 Sq M 40 mm 40 mm 50 mm 65 000 ltrs 92 000 ltrs 120 000 ltrs 8...

Page 3: ...ateral hub and stand pipe are intact inside the tank 3 Fill tank half full with water 4 Place the disposable loading disc into the upper tank opening and the plastic cover over stand pipe to stabilise the filter and stand pipe It is important that the stand pipe remains centered through the media loading procedure to ensure alignment with valve assembly opening 5 Proceed to load correct volume of ...

Page 4: ...ter tank 2 Prime pump 3 Set valve handle in BACK WASH position 4 Start pump and operate in BACK WASH cycle for three 3 minutes This will purge the filter of excess fines in the media 5 Turn pump OFF and set valve handle to RINSE Start pump and run for one 1 minute 6 Stop pump and set valve handle to FILTER Restart pump System is now operating on a normal FILTER cycle 7 Adjust the valves in the ski...

Page 5: ...ck inlet outlet o rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Annually Compare operating pressure of backwashed filter to initial pressure when new If using Zeolite or M3 regenerate filter media This is important in commercial applications as it aids in the removal of ammonias If pressure is more than 30 40 kPa different from new filter a media chan...

Page 6: ... years 80 covered 20 payable 5 6 years 60 covered 40 payable 7 8 years 40 covered 60 payable 9 10 years 20 covered 80 payable If a defect appears in the Product before the end of the warranty period and AstralPool finds the Product to be defective in materials or workmanship AstralPool will in its sole discretion either a replace or repair the Product or the defective part of the Product free of c...

Page 7: ...ny instructions by AstralPool e the Product has been subject to accident negligence alteration abuse or misuse The warranty does not extend to a normal wear and tear b weather and other environmental conditions including but not limited to storm flood and or heat wave damage or c service and maintenance items Examples of exclusions include but are not limited to sand used within the filter vessel ...

Page 8: ...Inst 246 RX Series E Series Sand Filter V01 15 8 ...