manualshive.com logo in svg
background image

ASSA ABLOY, the global leader
in door opening solutions

www.assaabloy.de

ASSA ABL

OY

Installation and Operating Instructions

D0117001

ePED

®

 display door terminal 1386D10

Escape route technology

Содержание Effeff ePED 1386D10

Страница 1: ...ASSA ABLOY the global leader in door opening solutions www assaabloy de ASSA ABLOY Installation and Operating Instructions D0117001 ePED display door terminal 1386D10 Escape route technology ...

Страница 2: ...tadt Germany Phone 49 0 7431 1230 Telefax 49 0 7431 123 240 Internet www assaabloy de Email albstadt assaabloy com Document number date D0117001 03 2030 Copyright 2020 ASSA ABLOY Sicherheitstechnik GmbH This document and all its parts are copyrighted Any use or changes outside the strict limits of the copyright are prohibited and liable to prosecution unless prior consent has been obtained from AS...

Страница 3: ...Authorisation 13 Login with authorisation code 14 Commissioning 16 Initial commissioning 16 Installation wizard 17 Operation 18 Emergency switch function 18 Display 19 Alarms and messages 20 Alarms 20 Messages 21 Maintenance 22 Resetting to factory settings 24 Technical data 25 Warranty disposal 26 Warranty 26 Updated information 26 Disposal 26 Table of contents ...

Страница 4: ...aning of the symbols Danger Safety notice Failure to observe these warnings will lead to death or serious injury Warning Safety notice Failure to observe these warnings can lead to death or serious injury Caution Safety notice Failure to observe these warnings can lead to injury Attention Note Failure to observe these warnings can lead to property damage and impair the function of the product Note...

Страница 5: ...is responsible for correct instal lation and functional inspection of the product and connected components The safe function must be tested by a trained qualified expert at least once per year Requirements established by inspection authorities must be complied with ASSA ABLOY Sicherheitstechnik GmbH offers training for qualification in the requisite skills Danger arising from tampering or improper...

Страница 6: ...ions and the device combinations required for your application The usage must be coordinated with the requirements of the inspection authorities Contact the responsible inspection authority for this purpose Compliance with all relevant inspection authority requirements is mandatory for the use particularly with respect to the coordination of the safety concept with the responsible inspection autho...

Страница 7: ...dforthesupplyofdeviceswithpowerconsumptionhigher than100VA Theappropriatemainsadapter cablelengths andcablecrosssections mustbechosenaccordingtothelocalcircumstances Checkandensurethattheoper ating voltage at the connection pointsis suitable for the components Identification of the cable Note Choose uniform identification for avoidance of errors In order to avoid errors and for a clearer overview ...

Страница 8: ...2 CAN_L br 3 VB gn 4 GND ye 5 ln VB 6 ln VB 7 Fire alarm system VB 8 Fire alarm system VB Syscon 4 plug connection 1 GND 2 CAN_H 3 CAN_L 4 VB No fire alarm 1 2 3 4 8 7 6 5 J1 J2 Temporary release 1 2 3 4 8 7 6 5 Fire alarm local connection 1 2 3 4 8 7 6 5 J1 J2 Fire alarm central connection 8 7 6 5 J1 J2 VB ...

Страница 9: ... B C D E F 1 2 3 4 SYSCON 4 1 2 3 4 8 7 6 5 J1 J2 ASSA ABLO Y Interface for locking systems 1386S00 Door terminal 1386D10 Hi O Technology power supply 1 Other locking elements can be connected instead of the escape door strike 331 manual D00470 Only one locking element may be connected ...

Страница 10: ...10 Fitting and installation EN Mounting removing the display 6 2 5 6 0 1 2 1 2 ...

Страница 11: ...11 Fitting and installation EN ASSA ABLOY ASSA ABLOY ASSA ABLOY ASSAABLOY ...

Страница 12: ...nterfaces for locking systems 1386S00 can be connected The maximum power consumption may not be exceeded The voltage supply must be sufficient for the power consumption of all connected components Limitation of function with incorrect operating voltage at the components A mainsadapterinaccordancewithrequirementsSELVmustbeused Separatemains adaptersmustbeconnectedforthesupplyofdeviceswithpowerconsu...

Страница 13: ...s The display shows operating symbols in the header area and information for interactive communication with the user The toolbar is not always completely visible One or two symbols are shown for operation or navigation a menu heading can be shown in the centre Authorisation There are three authorisation levels Control Authorisation for calling up information Settings Authorisation for calling up i...

Страница 14: ...he Systemmenu can only be opened with expanded authorisation An authorisation code for configuration is required for this 1 Press the symbol 2 Press the symbol The symbol is no longer shown 3 Press one of the symbols according to an authorisation code Tab 2 page 13 4 Enter an authorisation code Delete any numbers entered by mistake with the key 5 Confirm the entry with the key The menu is displaye...

Страница 15: ...e keyboard is displayed 5 Press one of the symbols according to an authorisation code Tab 2 page 13 6 Assign a new authorisation code Delete any numbers entered by mistake with the key 7 Confirm the entry with the key You have changed an authoisation code 8 If necessary repeat from step 5 until all authorization codes have been changed Fig 6 The System UserAdministration menu Authorisation level C...

Страница 16: ...curing system Allows the doors to be opened after actuation of the Emergency Open push button s The function must be tested when connected to fire alarm system The commissioning must be documented ASSA ABLOY Sicherheitstechnik GmbH offers a test log book for this purpose Initial commissioning All devices are connected to the Hi O Technology bus for the initial commission ing but are not configured...

Страница 17: ...carried out the installation must be started again from the beginning The RWT system configuration has not taken place and the system cannot be locked Using the installation wizard 1 Press the Continue or OK button if the entire dia logue message is correct or if you have taken the necessary action the Cancel button if any part of the dialogue message is incorrect or if you have not taken the nece...

Страница 18: ...ction Pressing the red area in the centre initiates a release and a pre alarm is triggered The emergency switch function is triggered if the display is pressed Fig 8 Press the Emergency Open switch ASSA ABLOY ASSA ABLOY ca 4 mm Operation ...

Страница 19: ...the remain ing wait time is displayed in seconds ASSA ABLOY ASSA ABLOY Escape route pictogram and status display The ePED display door terminal 1386D10 shows the relevant pictogram when the escape door is secured and indicates the correct conduct if the door needs to be operated in the event of an emergency ASSA ABLOY Operation and configuration Authorised users are identified via an au thorisatio...

Страница 20: ...r is not closed and locked within the pre alarm time a tamper alarm is triggered Fire alarm In the case of a fire alarm the Hi O Technology components are actuated by a fire alarm system The escape route locking systems are automatically unlocked and retain this status until actuation by the fire alarm system is lifted again If the actuation by the fire alarm system is lifted again the components ...

Страница 21: ...ssage The following statuses trigger a tamper message for a locked door The door is open and or the escape route locking system is unlocked The door remains in Locked status The tamper status can be reset centrally or at the door Tamper alarm has Locked status ...

Страница 22: ...cape route securing system should take place at a later time they must be recorded in the same manner as for an initial commissioning Ensure that all opening and closing functions of the escape door function with out limitation when the escape route securing system is deactivated Ensure that the escape door is secured after activation of the escape route securing system Ensure that the escape door...

Страница 23: ...n the following order 2 Enter your authorisation code 3 Press the System menu item 4 Press the Maintenance menu item You are in the Maintenance menu 5 Press the Maintenance menu item You have started the system test wizard 6 Follow the instructions shown 6 1 Press the Continue button to continue to test 6 2 Press the Cancel button to cancel the test incomplete Fig 9 The System Maintenance System t...

Страница 24: ...he operating voltage the device can be reset to the factory settings Reset to factory settings 1 Switch off the voltage supply for at least 10 seconds 2 Switch the voltage supply on again The symbol is shown 3 Press the symbol 4 Press the center of the display 5 Answer to the confirmation request After confirming the request the device is ready for use again and must be configured Fig 10 Resseting...

Страница 25: ...l control with central control without CE certification EU export with local control with central control 15s 180s 120s 300s Hi O Technology Control function Bus addresses Yes 2 Width Height Depth 113mm 99mm 29mm Application site for use in indoor areas Protection rating IP30 when completely mounted Operating temperature 10 C 55 C Certification in accordance with EltVTR DIN EN 13637 2015 Tab 3 Tec...

Страница 26: ...mation Updated information such as reports on current fire testing can be found online at www assabloy de Disposal Dispose of lock in accordance with the EPD Environmental Product Declaration Packaging materials must be recycled The product must be disposed of as electronic scrap The applicable environmental protection regulations must be observed www assaabloy de M Warranty disposal ...

Страница 27: ...27 EN ...

Страница 28: ...bstadt DEUTSCHLAND albstadt assaabloy com Tel 49 7431 123 0 Fax 49 7431 123 240 www assaabloy de ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience Technische Änderungen vorbehalten ...

Отзывы: