background image

SharpStreamer™ Pro PCIE-7210

Installation and Use

P/N: 6806800U29B
January 2017

Summary of Contents for SharpStreamer Pro PCIE-7210

Page 1: ...SharpStreamer Pro PCIE 7210 Installation and Use P N 6806800U29B January 2017...

Page 2: ...an Artesyn website The text itself may not be published commercially in print or electronic form edited translated or otherwise altered without the permission of Artesyn It is possible that this publ...

Page 3: ...ing and Inspecting PCIE 7210 Card 31 2 2 Environmental Thermal and Power Requirements 32 2 2 1 Environmental and Thermal Requirements 32 2 2 2 Power Requirements 33 2 3 Precautions 34 2 3 1 ESD Preven...

Page 4: ...7 Temperature Sensors 45 3 8 Clock Distribution 46 3 9 Reset Management 46 3 10 JTAG 47 4 Controls Indicators and Connectors 49 4 1 Connectors 49 4 1 1 PCIE 7210 Faceplate View 49 4 1 2 Edge Connecto...

Page 5: ...able USB on a Windows Machine 91 6 2 3 Booting via PXEboot 92 6 2 4 Installation 95 6 2 4 1 Automatic Installation 97 6 2 4 2 Manual Installation 98 6 3 Linux Distribution 100 6 3 1 Connecting the Con...

Page 6: ...device function from a CPU 120 7 6 2 7 List Assignments 120 7 6 2 8 Listing Assignments in the configuration layer 120 7 6 2 9 Get the assigned CPU of a device function 121 7 6 2 10 Get and Set the P...

Page 7: ...e 127 A 1 1 Obtaining Revisions of Firmware Components 127 A 1 2 Upgrade Procedure 128 A 1 3 Troubleshooting 134 A 1 3 1 CPLD FW Upgrade Failed 134 A 1 3 2 BMC FW Upgrade Failed 135 A 1 3 3 BMC Cannot...

Page 8: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 8 Contents...

Page 9: ...63 Table 4 7 CPU1 i219 LEDs 64 Table 4 8 CPU2 i219 LEDs 65 Table 4 9 CPU1 and CPU2 USB2240 LEDs 67 Table 5 1 BIOS Setup Menu Bar 74 Table 5 2 Legend Keys 75 Table 5 3 Main Menu 77 Table 5 4 Advanced M...

Page 10: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 10 List of Tables...

Page 11: ...CPU1 i219 LEDs 64 Figure 4 6 Location of CPU2 i219 LEDs 65 Figure 4 7 Location of CPU1 USB2240 LEDs 66 Figure 4 8 Location of CPU2 USB2240 LEDs 67 Figure 4 9 Reset Button S1 Location 68 Figure 4 10 Re...

Page 12: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 12 List of Figures...

Page 13: ...s Functional Description on page 39 provides information about the functional blocks in the SharpStreamer Pro PCIE 7210 card block diagram Controls Indicators and Connectors on page 49 provides inform...

Page 14: ...laceable Unit GPIO General Purpose Input Output HEVC High Efficiency Video Coding ISP Internet Service Provider JTAG Joint Test Action Group MAC Media Access Control MSO Multiple System Operator OTT O...

Page 15: ...n screenoutputandcoderelatedelements or commands in body text Courier Bold Used to characterize user input and to separate it from system output Reference Used for references and for table and figure...

Page 16: ...njury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Indicates a property damage message No danger encountered Pay attention to important information Notat...

Page 17: ...ined by Artesyn or persons qualified in electronics or electrical engineering are authorized to install remove or maintain the product The information given in this manual is meant to complete the kno...

Page 18: ...quency emissions compliance is maintained Operation Product Damage Surface of the Product High humidity and condensation on the product surface causes short circuits Do not operate the product outside...

Page 19: ...the product or electronic components make sure that your are working in an ESD safe environment Product Damage Incorrect installation of the product can cause damage of the product Only use appropria...

Page 20: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B Safety Notes 20...

Page 21: ...onen ben tigen sollten wenden Sie sich bitte an die f r Sie zust ndige Gesch ftsstelle von Artesyn Das System erf llt die f r die Industrie geforderten Sicherheitsvorschriften und darf ausschlie lich...

Page 22: ...hrt werden k nnen dazu f hren dass der Anwender die Genehmigung zum Betrieb des Produktes verliert Boardprodukte werden in einem repr sentativen System getestet um zu zeigen dass das Board den oben a...

Page 23: ...Funktionsf higkeitmu durcheinenqualifiziertenReparaturdienstwiederhergestelltwerden Installation Besch digung von Schaltkreisen Elektrostatische Entladung und unsachgem er Ein und Ausbau des Produkte...

Page 24: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B Sicherheitshinweise 24...

Page 25: ...H 265 High Efficiency Video Coding HEVC transcodes or four 4 streams of 1080p60 H 265 HEVC transcodes Each CPU offers one 1 4KP60 HEVC or up to two 2 4KP30 HECV transcodes The SharpStreamer Pro solut...

Page 26: ...1578L v5 PCI Express card for MaxCore server based installations in a video broadcasting and data server environment The card has PCIe x16 Gen 3 bus connected to standard gold finger edge In the MaxC...

Page 27: ...R679 C47 8 R681 R219 BF5 C169 M30 P1 P12 R272 R295 R294 R293 P13 R776 D22 BF4 R778 D21 C242 J1 C241 J13 C239 C238 J12 C244 S2 S3 M1 R318 M31 C243 Q4 U20 R79 R782 C15 C11 R84 R169 R191 R192 R178 R186...

Page 28: ...5 Class A ANSI C63 4 2003 FCC 15 109 g CISPR 22 1997 2003 Class A ANSI C63 4 2003 ICES 003 Issue 5 2012 Class A CAN CSA CISPR 22 2008 Radiated Emissions CISPR 22 2012 Class A CISPR 22 2012 EN 300 386...

Page 29: ...part number given in the following table when ordering a card supported software packages or requesting support information Consult your local Artesyn sales representative for more information Table 1...

Page 30: ...Introduction SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 30...

Page 31: ...nt Inspection To inspect the shipment perform the following steps 1 Verify that you have received all items of your shipment One SharpStreamer Pro PCIE 7210 card One printed copy of Quick Start Guide...

Page 32: ...equirements Make sure the card is thoroughly inspected before shipment If any damage has occurred during transportation please contact our Contact Center immediately Operating temperatures refer to th...

Page 33: ...erence to sea level 500 LFM 2 5 m sec 400 LFM 2 m sec for 35 C Operation Temperature Change 30 C hr 30 C hr Relative Humidity 5 to 85 Non Condensing 5 to 90 Non Condensing but not to exceed 0 024 kg o...

Page 34: ...ouch the circuit with bare hands The static electricity of the human body may damage the ElectroStatic Sensitive Devices ESSDs on the circuit Make sure that you wear an ElectroStatic Discharge ESD pre...

Page 35: ...elf Avoid moving as much as possible Movement gathers static electricity around you Do not touch the solder point pin or bare circuit Do not leave the device in the place where others can operate it I...

Page 36: ...which the PCIE 7210 card is to be installed 3 Remove the system cover Shipping the card along with a server is not recommended If you still need to ship the card along with the server ensure the card...

Page 37: ...ke sure you are in an ESD safe environment 2 Power off the system disconnect the system fromtheelectricaloutletand peripheralsand remove any cables connected to the card 3 Remove the system cover Make...

Page 38: ...PCIE 7210 Installation and Use 6806800U29B 38 4 Remove the screw holding the front panel bracket and gently pull the PCIE 7210 card from the slot 5 Close the cover of the system Place the PCIE 7210 ca...

Page 39: ...re depicts the functional block diagram of SharpStreamer Pro PCIE 7210 card 3 1 CPU Complex The CPU complex of PCIE 7210 card comprises an Intel E3 1578L v5 processor and a PCH Figure 3 1 SharpStreame...

Page 40: ...Skylake PCH The H Processor line of the Skylake is offered in a two chip platform Platform Controlled Hub PCH is a separate IC along with the E3 1578L v5 processor PCH controls certain data paths and...

Page 41: ...er 3 3 1 82599 The second Ethernet interface Port8 Port15 of each processor are used to directly connect both processors on the PCIE 7210 through a 10 Gigabit Ethernet connection 3 4 Power A 12 V powe...

Page 42: ...GT s DDR4 Intel E3 1578L v5 processor has two memory channels Each channel of processors is connected with DDR4 SODIMM 1 DIMM Per Channel DPC Inter Processor Communication Two 10 Gigabit Ethernet cont...

Page 43: ...ent Bus is used as interface between devices I2C0 This interface is connected to the inlet and outlet onboard temperature sensors 3 5 2 2 SVID The System V interface Definition SVID is a 3 wire digita...

Page 44: ...C645 C577 R959 R946 R945 R935 C646 C578 TP4 TP7 TP12 U59 U58 R940 R791 R8 14 R811 R8 78 R980 R981 R893 R933 R934 C638 C6 19 C621 TP8 R508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C632 L42 C...

Page 45: ...rive 3 6 3 MicroSD as Boot Device By default during the card boot operation the BIOS will first look for a boot record on the microSD storage device If no boot record is found then the card tries to P...

Page 46: ...C808 C805 C802 C798 TP92 R1102 R1098 R1096 R1104 R534 C762 TP85 U77 R968 R961 C645 C577 R959 R946 R945 R935 C646 C578 TP4 TP7 TP12 U59 U58 R940 R791 R8 14 R811 R8 78 R980 R981 R893 R933 R934 C638 C6...

Page 47: ...10 Installation and Use 6806800U29B 47 3 10 JTAG The PCIe slot JTAG pins are mapped to the CPLD JTAG programming pins CPLD programming port at connector P2 Independent connector for CPLD E3 1578L v5 a...

Page 48: ...Functional Description SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 48...

Page 49: ...ut the controls indicators and connectors associated with the PCIE 7210 card 4 1 Connectors 4 1 1 PCIE 7210 Faceplate View The following figure shows the faceplate view of PCIE 7210 card Figure 4 1 PC...

Page 50: ...12V 12 Volt power 3 RSVD Reserved 12V 12 Volt power 4 GND Ground GND Ground 5 SMCLK PCIE EDGE SMBCLK SMBus System Management Bus Clock JTAG2 PCIe Edge Test Clock TCK 6 SMDAT PCIE EDGE SMBDAT SMBus Sy...

Page 51: ...eceiver Lane 2 26 GND Ground Rx_N 2 Differential pair 27 Tx_P 3 Transmitter Lane 3 GND Ground 28 Tx_N 3 Differential pair GND Ground 29 GND Ground Rx_P 3 Receiver Lane 3 30 GND Reserved Rx_N 3 Differe...

Page 52: ...air GND Ground 52 GND Ground Rx_P 8 Receiver Lane 8 53 GND Ground Rx_N 8 Differential pair 54 Tx_P 9 Transmitter Lane 9 GND Ground 55 Tx_N 9 Differential pair GND Ground 56 GND Ground Rx_P 9 Receiver...

Page 53: ...itter Lane 14 GND Ground 75 Tx_N 14 Differential pair GND Ground 76 GND Ground Rx_P 14 Receiver Lane 14 77 GND Ground Rx_N 14 Differential pair 78 Tx_P 15 Transmitter Lane 15 GND Ground 79 Tx_N 15 Dif...

Page 54: ...N SM Bus alert signal CON SLOT ID1 10 GND Ground CON SLOT ID2 11 PCH2_U ART1_EX T_TXD UART1 to PCH2 transmitter CON SLOT ID3 Mechanical Key 12 PCH2_U ART1_EX T_RXD UART1 to PCH2 Receiver GND Ground 13...

Page 55: ...Transmitter Diff pair 22 GND Ground PCH2_GE0 _EXT_TX_ D_M 23 PCH1_GE 0_EXT_R X_D_P Gigabit Ethernet port to PCH1 Receiver diff pair GND Ground 24 PCH1_GE 0_EXT_R X_D_M GND Ground 25 GND Ground PCH1_GE...

Page 56: ...cted 35 NC Not connected NC Not connected 36 NC Not connected NC Not connected 37 NC Not connected NC Not connected 38 NC Not connected NC Not connected 39 GND Ground GND Ground 40 PCH2_LP C_LAD0 LPC...

Page 57: ...2_IOM OD_DP USB2 port to PCH2 PCH1_CLK OUT_LPC0 LPC clock to PCH1 51 PCH2_US B2_IOM OD_DM Differential pair GND Ground 52 GND Ground PCH1_USB 2_IOMOD_ DP USB2 port to PCH1 53 GND Ground PCH1_USB 2_IOM...

Page 58: ...TA0_RX_ D_P SATA0 port to PCH2 Receiver Diff pair GND Ground 63 PCH2_SA TA0_RX_ D_M GND Ground 64 GND Ground PCH2_SATA 0_TX_D_P SATA0 port to PCH2 Transmitter Diff pair 65 GND Ground PCH2_SATA 0_TX_D_...

Page 59: ...D_M 74 PCH1_SA TA0_RX_ D_P SATA0 port to PCH1 Receiver Diff pair GND Ground 75 PCH1_SA TA0_RX_ D_M GND Ground 76 GND Ground PCH1_SATA 0_TX_D_P SATA0 port to PCH1 Transmitter Diff pair 77 GND Ground PC...

Page 60: ...icro USB UART port is the UART0 port of the PCH through CP2105 F01 GMR silabs device 4 1 5 MicroUSB Port The micro USB port is the USB 1 port of the PCH Table 4 3 Micro USB UART port pinout Pin Name 1...

Page 61: ...508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C632 L42 C634 C630 L48 D8 R3 68 C2 75 R375 R372 C281 C277 R411 R405 R408 R1089 C327 R336 R337 R1081 R1111 R460 R1100 C740 R954 R970 C365 R949 R86...

Page 62: ...R696 8 9 6 R 7 9 6 R R685 R686 R692 R693 C492 C493 M11 R281 R511 U17 C206 C208 L14 R252 R651 R655 R656 C200 Q11 R678 R669 R679 C47 8 R681 R219 BF5 C169 M30 P1 P12 R272 R295 R294 R293 P13 R776 D22 BF4...

Page 63: ...959 R946 R945 R935 C646 C578 TP4 TP7 TP12 U59 U58 R940 R791 R8 14 R811 R8 78 R980 R981 R893 R933 R934 C638 C6 19 C621 TP8 R508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C632 L42 C634 C630 L48...

Page 64: ...968 R961 C645 C577 R959 R946 R945 R935 C646 C578 TP4 TP7 TP12 U59 U58 R940 R791 R8 14 R811 R8 78 R980 R981 R893 R933 R934 C638 C6 19 C621 TP8 R508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C6...

Page 65: ...R980 R981 R893 R933 R934 C638 C6 19 C621 TP8 R508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C632 L42 C634 C630 L48 D8 R3 68 C2 75 R375 R372 C281 C277 R411 R405 R408 R1089 C327 R336 R337 R108...

Page 66: ...R835 R839 C632 L42 C634 C630 L48 D8 R3 68 C2 75 R375 R372 C281 C277 R411 R405 R408 R1089 C327 R336 R337 R1081 R1111 R460 R1100 C740 R954 R970 C365 R949 R862 R864 R874 R875 R923 R831 R815 R979 R925 R92...

Page 67: ...23 R835 R839 C632 L42 C634 C630 L48 D8 R3 68 C2 75 R375 R372 C281 C277 R411 R405 R408 R1089 C327 R336 R337 R1081 R1111 R460 R1100 C740 R954 R970 C365 R949 R862 R864 R874 R875 R923 R831 R815 R979 R925...

Page 68: ...C646 C578 TP4 TP7 TP12 U59 U58 R940 R791 R8 14 R811 R8 78 R980 R981 R893 R933 R934 C638 C6 19 C621 TP8 R508 R509 R765 R829 R865 R922 C622 TP17 R1123 R835 R839 C632 L42 C634 C630 L48 D8 R3 68 C2 75 R3...

Page 69: ...31 C243 Q4 U20 R79 R782 C15 C11 R84 R169 R191 R192 R178 R186 R190 R780 R781 R783 C84 C10 C125 C127 C336 C337 R419 R429 R427 R425 C334 M9 R773 R415 R416 C576 M29 BF6 L4 R52 R381 R320 R321 R319 R383 R72...

Page 70: ...Controls Indicators and Connectors SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 70...

Page 71: ...data Boot configuration for a flexible boot order The BIOS Setup program is required to configure the hardware of the card This configuration is necessary for operating the card and the peripherals co...

Page 72: ...it after making a selection in the setup menus This procedure stores the selections displayed in the menus in CMOS At the time of next boot up BIOS configures the system according to the setup selecti...

Page 73: ...9 to restore the system defaults Or 1 Press F2 to return to the BIOS setup 2 Go to the Exit menu and select Load setup Defaults The default BIOS values are loaded and the values will affect all setup...

Page 74: ...value for that field After that use Save Change Without Exit command in the Exit menu to save the values currently displayed in all the menus Table 5 1 BIOS Setup Menu Bar Menu Description Main Config...

Page 75: ...the active selection is displayed Table 5 2 Legend Keys Key Function F1 Displays general help window Esc Exits the menu or the BIOS Setup program without saving any changes Left and Right Arrow Keys...

Page 76: ...window The general help window describes the legend keys and their alternates as shown in the following figure The scroll bar on the right side of any window indicates that there is more than one page...

Page 77: ...screen items scroll down the Main screen The following screen appears The following table provides the list of features that can be configured in Main menu By default the Main tab is selected on the...

Page 78: ...ew Advanced menu select Advanced tab from the menu bar Use the legend keys to make a selection or exit in from the Advanced menu System Time HH MM SS Set the system time System Date MM DD YYYY Set the...

Page 79: ...her configurations shown in the Advanced menu are default values and need not be configured 5 2 2 1 Boot Configuration The following figure shows the Boot Configuration submenu Table 5 4 Advanced Menu...

Page 80: ...llowing figure shows the Console Redirection Setup submenu screen The settings are applied to all ports if selected Individual submenus are available if there is a need for separate port configuration...

Page 81: ...n Description Console Serial Redirection Enabled Disabled Enables or disables the Console Redirection Terminal Type VT_100 VT_100 VT_UTF8 PC_ANSI Selects the terminal type Baud Rate 115200 57600 38400...

Page 82: ...Force 80x25 Force 80x24 DEL FIRST ROW Force 80x24 DEL LAST ROW Selects the text mode resolution AutoRefresh Disabled Enabled Selects if the terminal will be refreshed after a console is detected FailS...

Page 83: ...rom the menu bar Use the legend keys to make a selection and exit from the Security menu TheSecurity menuappearsas showninthe following figure The following table provides other options in the Securit...

Page 84: ...4 5 2 4 Power Menu To view the Power menu select the Power tab from the menu bar The Power menu is displayed which looks similar to the following figure Table 5 7 Security Menu Feature Option Descript...

Page 85: ...le provides options in the Boot menu and their default settings Figure 5 9 Boot Menu Table 5 8 Boot Menu Feature Option Description Boot Type Dual Boot Type Legacy Boot Type UEFI Boot Type Selects the...

Page 86: ...boot device ACPI Selection Acpi1 0B Acpi3 0 Acpi4 0 Acpi5 0 Selects the supported ACPI version USB Boot Enabled Disabled Enables or disables USB boot support EFI Device First Disabled Enabled Selects...

Page 87: ...a selection or exit to the main menu The Exit menu screen looks similar to the figure below The following table provides Exit menu features and their description The values shown in the tables enclos...

Page 88: ...e Changes Without Exit Saves the changes without exiting Exit Discarding Changes Exits the setup and discards the changes Load Setup Defaults Loads the default setup parameter Discard Changes Discards...

Page 89: ...ion number iso This ISO contains necessary files for creating a bootable CDROM USB PXEbooting and disk installation Artesyn provides software images which also includes the software updates Contact yo...

Page 90: ...to install software on the disk from each of these bootable sources 6 2 1 Booting via CD DVD Prerequisite You need a CD DVD of at least 600MB free space To boot the software from CD ROM perform the f...

Page 91: ...rive 2 Mount the MC3K_7210_OS_CENTOS72_DIST_ Release and Version number iso to a directory mkdir p mnt mount MC3K_7210_OS_CENTOS72_DIST_ Release and Version number iso mnt 3 Run the create_bootusb sh...

Page 92: ...menu and perform the following steps a Select UEFI mode b Select the USB drive as the first bootable drive c Save and exit 6 2 3 Booting via PXEboot Prerequisites Linux host that acts as TFTP and DHC...

Page 93: ...b cfg tftpboot 7210 EFI 3 Modify the following lines in the grub cfg file linuxefi images vmlinuz initrdefi images ramfs gz to linuxefi 7210 images vmlinuz initrdefi 7210 images ramfs gz TFTP Server C...

Page 94: ...conf 5 man page option space PXE option arch code 93 unsigned integer 16 RFC4578 allow bootp allow booting authorative default lease time 1209600 max lease time 1814400 subnet 192 162 23 0 netmask 25...

Page 95: ...e installation onto a disk BIOS must be set to UEFI mode Bootable USB drive or PXEboot source from which software is installed Disk for installation USB drive or SD card iSCSI based disk Note Disk sho...

Page 96: ...on i image download options n ntpserver Options d installation option for disk based d disk disk name for iscsi based d iscsi initiator_name initiator_intface_name target_ip target_port target_name i...

Page 97: ...d disk sda i local media usbdrive images 6 2 4 1 2 iSCSI disk If the installation is onto a iSCSI disk with following information Usage Command opt bladeservices tools flashrfsrc sh d iscsi iqn 2016 0...

Page 98: ...disk installation This procedure needs manual intervention to provide inputs 6 2 4 2 1 Local disk installation The following are the steps you need to perform for manual installation on a local disk...

Page 99: ...n on page 100 6 2 4 2 2 iSCSI disk installation The following are the steps you need to perform for iSCSI based disk installation 1 Run the following command opt bladeservices tools flashrfsrc sh 2 Se...

Page 100: ...rget port and initiator interface 9 Login For more information refer to the section Linux Distribution on page 100 6 3 Linux Distribution The distribution is based on CentOS 7 2 The Kernel version is...

Page 101: ...ole ttyS1 115200n8 To use sol console use the second option during the bootup in the GRUB prompt console ttyS2 115200n8 6 3 1 2 Ethernet Interfaces None of the network interfaces are configured except...

Page 102: ...or example if Base OS is based on CentOS7 2 then use a host machine installed with CentOS7 2 Procedure To modify ramfs perform the following steps 1 Mount the Base OS ISO to a directory For example mn...

Page 103: ...Use 6806800U29B 103 5 Modify the files sha1sum file with updated sha1sum of ramfs xz or ramfs gz files1 sha1sum is used during installation and it needs to be in the same location as ramfs gz ramfs x...

Page 104: ...Base Operating System SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 104...

Page 105: ...following RPMs Table 7 1 Package Information Package Name Description board utils Disk installation utilities pcie mcpu basenet Network configuration files creation pcie filesystem File structure for...

Page 106: ...all Kernel updates if any If they are already installed go to step 2 2 Install PCIe Update For more details refer to the section PCIE Update on page 107 3 Upgrade the firmware For more details refer t...

Page 107: ...n directory For example To mount the ISO to mnt directory run the following command mount t MC3K_7210_OS_CENTOS72_PCIE_UPDATE_ Release and version number iso mnt To install the PCIE update software ru...

Page 108: ...es fcu and pcie firmware pcie firmware RPM located in opt bladeservices rom location contains BIOS and CPLD firmware fcu RPM provides utilities to query and upgrade the BIOS and CPLD firmware The comm...

Page 109: ...ion is 01 05 00 Device 01 represents BIOS and the firmware version is 2 0 00000000 To upgrade BIOS use the following command fcu uf BIOS image fri Here BIOSimage friisthefirmwarefiletowhichBIOSwill be...

Page 110: ...the card After the reboot the following screen is displayed Wait until the above procedure is successful After the cards boots to Linux to confirm whether the BIOS is upgraded execute the fcu q comma...

Page 111: ...screen shows a typical output when the above command is executed To upgrade CPLD use the following command fcu uf CPLD image fri Here CPLD image fri is the firmware file to which CPLD will be upgrade...

Page 112: ...kage boardctrl 7 4 1 PCIE Sensors Utility The PCIE 7210 card is populated with hardware sensors for temperature and power readings The utility provides readings of CPU core temperatures Power SPD and...

Page 113: ...ased on the MaxCore slot in which the PCIE card is placed Each slot has two CPUs The host name of card will have the following convention pcie7210s slot_id c cpu_number For example for a CPU in slot6...

Page 114: ...p sequence of the MaxCore system You can initiate the MaxCore system by plugging in the power cable to any of the three power supplies Start up Sequence 1 The backplane management power is available a...

Page 115: ...iguration is valid If it is not a new configuration an automatic reboot is performed If a reboot is performed then the sequence restarts from step 4 7 The MCCS service powers Application CPUs aCPUs of...

Page 116: ...s powered on by the MCCS service at Management CPU startup If the Management CPU was rebooted due to a configuration change or manually by the user then an already powered Application CPU is reset 7 6...

Page 117: ...pen source project like Openstack The following figure shows the software architecture block diagram The MaxCore Configuration Service MCCS displays the following features List device functions behind...

Page 118: ...rst That means all modifications will not be applied directly to the hardware They will be stored in the configuration layer and will be set after applying the configuration followed by necessary rebo...

Page 119: ...t port number of the CPU You can get this information using the list methods list cpus and list devices If a device function is already assigned to another CPU you have to remove it first with the rem...

Page 120: ...on you can get a list of device function for a CPU and its root port For example for CPU number 2 and root port 1 in slot 1 mccs_tool py method list assigned funcs cpu 1 2 1 In the list you will find...

Page 121: ...nd mccs_tool py method set base mode respectively To get the actual PEX mode use the command mccs_tool py method get pex mode To return the PEX mode use the command mccs_tool py method get cfg pex mod...

Page 122: ...SATA disk is assigned to which CPU use the command mccs_tool py method list assigned disks You can assign a disk to a CPU using the command mccs_tool py method assign disk cpu slot cpu num port num di...

Page 123: ...MCCS Config File at BMC mCPU host can be in any of the following locations SLOT1 CPU1 CPU2 or SLOT15 CPU1 CPU2 When mCPU moves from one location to another mccs configuration cannot be moved because...

Page 124: ...aCPU gracefully from mCPU aCPU needs mcmsgd service This service is started at Linux startup by the systemd You can poweroff or reboot an aCPU through the MCCS service with help of the mccs_tool on mC...

Page 125: ...two10G ports are connected to external network 7 7 3 mCPU Bydefault PFsofalldevicecardsarevisibleonmCPU BackplaneNianticPFsarevisibleasETH3 ETH4 interfaces If a PCIE 9205 card is available in one of...

Page 126: ..._id f function For example e_s16d2f3 represents s16 device2 function3 is assigned to this aCPU For slot 16 VF PF IP addresses are fetched via DHCP from mCPU Devices are identified via their MAC addres...

Page 127: ...ing Artesyn s SSF to upgrade Firmware components SSF is the preferred method to upgrade the MaxCore firmware For more information refer to System Services Framework for MaxCore Platform XML Interface...

Page 128: ...ions ipmitool I lan H 192 168 201 9 U admin P admin hpm check A 1 2 Upgrade Procedure This section describes the step by step procedure to upgrade firmware images on a MaxCore MC3000 prototype Procedu...

Page 129: ...port two firmware images active and inactive to be maintained Firmware upgrades via web browser are only supported by firmware revisions higher than v1 0 10 the BMC firmware revision can be retrieved...

Page 130: ...30 To view more details open the Dual Image Configuration screen by clicking Firmware Update Dual Image Configuration In the Dual Image Configuration screen choose the required Image that need to be b...

Page 131: ...0 Installation and Use 6806800U29B 131 To open Firmware Update screen click Firmware Update Firmware Update from menu bar Figure A 2 Firmware Update Upgrade Do not modify the image to be updated Never...

Page 132: ...ipmitool I lan H 192 168 201 9 U admin P admin hpm upgrade mc3000 cpld companion 0 2 6 hpm component 3 force 3 Upgrade the Glue CPLD You can skip this step if the Glue CPLD firmware already has the m...

Page 133: ...l I lan H 192 168 201 9 U admin P admin hpm upgrade mc3000 cpld iomod 0 4 0 component 4 force If you observe that the firmware upgrade fails repeat the firmware upgrade procedure again Firmware upgrad...

Page 134: ...ool loads the firmware image into the BMC This may take some time 2min In the next step the ipmitool states Writing firmware 100 completed Please do not stop execution at this point ipmitool is still...

Page 135: ...rocedure If subsequent CPLD firmware upgrade fails contact your local Artesyn executive A 1 3 2 BMC FW Upgrade Failed In such a case power cycle the system and repeat the firmware upgrade If subsequen...

Page 136: ...MaxCore Firmware Upgrade SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 136...

Page 137: ...our Web site for the latest copies of our product documentation 1 Go to www artesyn com computing support product technical documentation php 2 Under FILTER OPTIONS click the Document types drop down...

Page 138: ...Related Documentation SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 138...

Page 139: ......

Page 140: ...syn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies Inc All other product or service names are the property of their respective owners 2017...

Reviews: