background image

P/N 1011504 Rev B 11/18

®

Rapid Steamer

Manufacturing Number: 

9100651

Owner’s Manual

RS-1000 INTL

www.antunes.com

IPX

3

           Rating

Summary of Contents for RS-1000 INTL

Page 1: ...P N 1011504 Rev B 11 18 Rapid Steamer Manufacturing Number 9100651 Owner s Manual RS 1000 INTL www antunes com IPX3 Rating ...

Page 2: ...or incorrect shipment to the delivery agent Record the model number serial number and installation date of your steamer and keep this information for future reference In Case of Damage If the steamer arrives damaged file a claim with the carrier immediately Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under warrant...

Page 3: ...with applicable federal state and local codes Maintenance y y Do not use abrasive materials they can damage the steamer s stainless steel finish y y Do not use corrosive chemicals in this equipment y y Chlorides or phosphates in cleaning agents e g bleach sanitizers degreasers and detergents can permanently damage stainless steel equipment The damage is usually in the form of discoloration dulling...

Page 4: ... C B Specifications Mfg No Volts Watts Amps Hertz Plug Description Plug Configuration 9100651 200 240 5000 30 50 60 HRN IEC309 Electrical Ratings Mfg No A Width B Depth C Height 9100651 17 39 441 7mm 16 86 428 24mm 12 79 324 87mm ...

Page 5: ...trol for the unit Treat the GUI interface with the same care as you would any touchscreen device Do not use tools or objects on the GUI Do not scratch or damage the GUI Figure 1 Components Steam Baskets Water Pan Basket Liner Assembly Basket Riser Top Cover Steam Vent Assembly Graphical User Interface GUI Power Button Water Flow Regulator Touchscreen Icons Increase Used to increase a value Increme...

Page 6: ...food item you are cooking is already shown on the display you can simply press it 6 The unit begins the cooking cycle The display shows the time re maining in the cooking cycle and beeps when cooking is complete 7 Remove the basket s from the unit and continue with food prepa ration as required 8 When cooking is complete the unit returns to the Ready screen Power Button Touchscreen GUI DISPLAY Fig...

Page 7: ...ime The length of time in minutes and seconds for the full cooking cycle You can also press Cancel to cancel the edit and return to the Select Function screen Edit Menu Item Add Menu Item Cancel Copy Menu Item Factory Reset Delete Menu Item Creating New Menu Items Creating new menu items follows the same procedure as editing an existing menu item The only difference is that you press Add Menu Item...

Page 8: ...ith a USB interface on the back of the unit This allows you to load menu items into the system To load a menu file Make sure the unit displays the Ready or Heating screen Insert the USB memory stick loaded with the electronic menu file into the USB connection Figure 3 1 Press Tools to open the Tools screen 2 Press USB Import The system reads the USB device and displays a list of acceptable menu fi...

Page 9: ... Press the Power button to turn the unit off The unit enters a cool down mode and will shut down automatically NOTICE You do not need to wait until the cool down mode completes However the unit will be hot so wear heat resistant gloves dur ing cleaning 2 Put on heat resistant gloves and remove the items in Figure 4 3 Wash rinse and sanitize the items removed at the sink Allow to air dry 4 Wipe the...

Page 10: ...es become free of mineral deposits add ordinary tap water non reverse osmosis or ionic filter system to casting and allow to boil off NOTICE In soft water areas it may be necessary to add a small amount of lime to generator to season it This will ensure proper steaming characteristics by producing a thin coating of mineral deposits on the casting Seasoning mixture consists of 75 ml 2 1 4 oz baking...

Page 11: ...tion Unit displays system error FRAM Control board is inoperable Reset the unit If the problem persists contact your maintenance person or Authorized Service Agency for service Unit displays system error Database Failure Possible data corruption on the receipts Do a factory reset from the Menu Items menu to reset stored receipts Reenter any missing receipts Unit heats but little or no steam is pro...

Page 12: ... P N 1011504 Rev B 11 18 12 Wiring Diagram ...

Page 13: ...ervice Warning 1 33 1001062 Label Water and Waste Conn 1 34 1001213 Label Shock Hazard 1 35 1002726 Label Control Panel 1 Item No Part Description Qty 36 1002778 Label Wiring Diagram 1 37 1031402 Spec Label 9100651 1 38 2120276 Spacer k 3 16 OD x 5 32 4 39 2140101 Adhesive Sealant RTV 1 40 2140144 Tape Pipe Thread 2 41 2180514 Clamp Cable Polypropylene 1 42 2190240 Pipe PTFE 2 43 3000102 Nut Speed...

Page 14: ... P N 1011504 Rev B 11 18 14 Replacement Parts 48 6 22 17 1 14 ...

Page 15: ... P N 1011504 Rev B 11 18 15 Replacement Parts Sheet 2 55 12 15 14 52 15 12 55 47 41 25 60 55 42 40 52 51 49 9 9 52 50 62 53 65 3 ...

Page 16: ... P N 1011504 Rev B 11 18 16 Replacement Parts Sheet 3 20 14 54 30 18 52 31 43 59 63 45 44 61 46 64 38 35 66 ...

Page 17: ... P N 1011504 Rev B 11 18 17 Replacement Parts Sheet 4 29 10 52 28 54 56 58 5 26 14 23 ...

Page 18: ... P N 1011504 Rev B 11 18 18 Replacement Parts Sheet 5 2 52 24 36 13 4 24 52 ...

Page 19: ... P N 1011504 Rev B 11 18 19 Replacement Parts Sheet 6 57 27 7 16 21 19 11 52 ...

Page 20: ... P N 1011504 Rev B 11 18 20 Notes ...

Page 21: ...m the nearest authorized service agency 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the ...

Reviews: