Operating  voltage

voltage  range

Allowable  operating

Rated  frequency

Contact  rating

Indicator  operating

Power  consumption

Life

Ambient  temperature

Ambient  humidity

Weight

Mechanical : 5,000,000 times  /  Electrical : 100,000 times

85 ~ 110% of  rated  operating  voltage

50 / 60 Hz

POWER - Red  /  RELAY ON - Green

250VAC 10A (Resistive  load)

Approx.  3.3VA

-10 ~ +50 

°

C

MAX  85% RH

Approx.  170g

AC/DC : 12 ~ 48V  /  AC/DC : 100 ~ 240V

APT-8S / APT-9S 

WEEKLY PROGRAMMABLE TIMER 

User's Manual

SAFETY  PRECAUTION

BUTTON and SWITCH FUNCTIONS

SPECIFICATIONS

OPERATING  FLOWCHART

Θʳ

DAY

   : Weekday setting

Θʳʳ

HR

    : Hour setting

Θʳ

MIN

    : Minute setting

Θʳ

SEC  

  : Second setting

Θ

PROG. 

  : Program number setting

Θ

MODE  

 : Mode status selecting

Θ

START 

  : Normal mode setting

Θ

CLEAR

  : Clear setting

Θ

12/24H

  : 12H or 24H setting

Θʳ

+1H

    : Daylight-saving-time setting

Θʳ

MAN  

  : Mandatory contact enable or disable

Θ

RESET

  : Program reset

Θ

TIMER

 : Timer mode

Θ

min

     : Unit of minute (in TWIN TIMER)

Θ

PULSE

 : Pluse mode

Θ

sec  

    : Unit of second (in TWIN TIMER)

Θ

ON

      : Power on (Battery on)

Θ

OFF

     : Power off (Battery off)

This manual uses the following symbols to ensure safe operation of this timer.

WARNING
CAUTION

Warnings are indicated when mishandling this controller might result in death or serious injury 

Cautions are indicated when mishandling this controller might result in minor injury to the user, 

to user.

or only physical damage to the timer.

Θ

Note this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has  

    been correctly wired before turning the power ON.

Θ

Before wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause  

    electric shock.

Θ

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Θ

Do not disassemble the controller. Doing so might cause electric shock or faulty operation.

Θ

Use the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,  

    shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.

Θ

Firmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.

WARNING

CAUTION

When using this product in applications  
that require particular safety or when  
using this product in important facilities,  
please pay attention to the safety of the  
overall system and equipment. Install fail- 
safe mechanisms, perform redundancy  
checks and periodic inspections and  
adopt other appropriate safety measures  
when it is necessary.

RESTRICTIONS ON USE

SET  SUMMER TIME

SHIFT THE OUTPUT STATUS

(MOMENTARY OPERATION)

SHIFT THE OUTPUT STATUS

(PEMANENT OPERATION)

NORMAL

+1H

MAN

MAN

SELECT 12H OR 24H

12/24H

SET WEEK

SET  HOUR

SET  MINUTE

PROGRAM ENABLE OR DISABLE

NORMAL MODE

PULSE SETTING

SET PROGRAM NUMBER

PROG.

SET PULSE WIDTH SECOND

SEC

HR

MIN

CLEAR

START

CHANGE TO THE PROGRAM MODE

MODE

CHANGE TO THE NORMAL MODE

MODE

SET  HOUR

OR

SET  MINUTE

CLEAR EEPROM(

APT-9S only

)

CLOCK SETTING

HR

MIN

CLEAR

SET  WEEKDAY

DAY

MO

MO

TU

WE TH FR SA

SU

TU

TU

S T

E

RESET

OFF

BAT.

ON

5S

3S

MO

CLK

AM

PM

MO

CLK

MO

CLK

1h

+

ON

OFF

MO

CLK

ON

OFF

MO

CLK

S T

E

S T

E

ON

MO

S T

E

ON

MO TU

WE TH FR SA

SU

S T

E

ON

MO TU

S T

E

ON

MO TU

S T

E

ON

MO TU

S T

E

MO

CLK

MAN

DAY

DAY

For APT-9S

For APT-8S

SET WEEKDAY

SET  HOUR

SET  MINUTE

PROGRAM ENABLE OR DISABLE

NORMAL MODE

TIMER SETTING

HR

MIN

PROG.

CLEAR

START

ON

MO

TU

WE TH FR SA

SU

S T

E

ON

TU

S T

E

ON

TU

S T

E

SET  HOUR

SET  MINUTE

HR

MIN

OFF

TU

S T

E

OFF

TU

S T

E

OFF

TU

S T

E

MO

CLK

TIMER

PULSE

TIMER

PULSE

ON

MO

S T

E

SET OFF TIME

OFF

TU

S T

E

Setting example :

There is a machine needed to be turned on at 8:00 AM and to be turned off at 5:00 PM, from Monday to Friday. 
In addition, the machine needed to be turned on at 9:00 AM to 11:00 AM every Saturday for inspection.  
The correct setting display should be as follows.

TIMER METHOD

PROGRAM MODE

(Choose ONE method ONLY)

NORMAL MODE

CLOCK MODE

PULSE METHOD

OFF

AM

SA

S T

E

ON

AM

SA

S T

E

OFF

PM

MO TU WE TH FR

S T

E

ON

AM

MO TU WE TH FR

S T

E

TU

1

2

3

MAN

DAY

DAY

For APT-9S

For APT-8S

http://waterheatertimer.org/Woods-timers-and-manuals.html#ingram

 

Reviews: