IMPORTANT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Manufactured by: 

ANEST IWATA Corporation

3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan

Instruction Manual

Max. Pressure:

6.8 bar (98 PSI)

Max. Temperature:

Noise Level (LAeqT)

76.8 dB (A)

Atmosphere

5 ~ 40 °C

Spray conditions

Recommended

Air and fluid

5 ~ 43 °C

Measuring point

1m backwards from gun, 1,6 m height

Air connection:

G 1/4”

Fluid connection:

G 3/8”

This 

ANEST IWATA

spray guns kit complies to ATEX regulations 94/9/EC, protection level:

II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. 

W 200 WB SPRAY GUN 

Before use, adjustment or maintenance, it is important to read this instruction manual very 
carefully. This manual must be stored in a safe place for any future reference that may be necessary. 

GB

MJ1435-05EREV

.03

Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following        marked items which are especially important.

WARNING

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-
perty damage.

IMPORTANT

Indicates notes which we ask you to observe.  The safety precautions in this instruction manual are the mini-
mum necessary conditions.  Follow national and local regulations regarding fire prevention, electricity and 
safety as well as your own company regulations.

Model

Nozzle orifice 

Air pressure

Air

Fluid output

Pattern

Air cap

Weight

at gun inlet

consumption

width

mm (in) 

bar (PSI)

l/min (cfm)

ml/min 

mm (in)

g (lbs)

High T.E.C. W200 WB Pressure feed

W200-WB-081P

0.8 (0.031)

200

360 (14.2)

W200-WB-101P

1.0 (0.039)

250

360 (14.2)

W200-WB-121P

1.2 (0.047)

300

380 (15.0)

High T.E.C. W200 WB Suction feed

W200-WB-162S

1.6 (0.063)

170

315 (12.4)

W200-WB-182S

1.8 (0.071)

200

330 (13.0)

380

(0.84)

WB1

WB2

340 (12)

1.6 (23)

2.0 (29)

430 (15)

ANEST IWATA Italia S.r.l.

46, Corso Vigevano 10155, Torino (Italy

)

Tel. d39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
[email protected]

www.anest-iwata.it

ANEST IWATA Iberica

Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93 - Fax.:+34 933 20 59 65
[email protected]

www.anest-iwata.es

ANEST IWATA Europe s.r.l.

NIEDERLASSUNG DEUTSCHLAND

Mommsenstrasse 5, 04329 Leipzig

Telefon: +49 (0)341 241 4430 - Fax: +49 (0)341 252 5595

[email protected]      

www.anest-iwata.de

ANEST IWATA Europe S.r.l.

46, Corso Vigevano 10155, Torino Italy
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 000
[email protected]

www.anest-iwataeu.com

ANEST IWATA Scandinavia 

Ögärdesvägen 6C, 433 30 PARTILLE - Sweden 
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
[email protected]

www.anest-iwata.se

ANEST IWATA France 

25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
[email protected]

www.anest-iwata.fr

ANEST IWATA  U.K.

Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH 
Tel.: +44 (0) 1480 405419  Fax: +44 (0) 1480 217610
[email protected]

www.anest-iwata.co.uk

European Sales Branches:

Reviews: