background image

IMPORTANT

This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equip-
ment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.  

ANEST IWATA

disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro-

cedures as from this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any dam-
age during transportation is found, or details of training courses, please contact your nearest 

ANEST IWATA Company 

(see last

cover page).

Manufactured by: 

ANEST IWATA Corporation

3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan

Instruction Manual

This 

ANEST IWATA

spray guns kit complies to ATEX regulations 94/9/EC 

Protection level: II 2 G X Suitable for using in Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. 

TOF-5 / TOF-6 AUTOMATIC SPRAY GUN
TOF-5R / TOF-6R (round pattern) AUTOMATIC SPRAY GUN

Before use, adjustment or maintenance, it is important to read

this instruction manual very carefully. This manual must be

stored in a safe place for any future reference that may be necessary. 

GB

T013-02EREV

.02

IMPORTANT SPECIFICATIONS

Max. Pressure:

6.8 bar (98 PSI)

Max. Temperature:

Noise Level (LAeqT)

69.4 dB(A)*

Atmosphere

5 ~ 40 °C

Air connection:

G 1/8”

Air and fluid

5 ~ 43 °C

Fluid connection:

G 1/8”

TECHNICAL SPECIFICATIONS

Be sure to observe warnings and cautions in this instruction manual.

If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.

Be sure to observe following        marked items which are especially important.

WARNING

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-

perty damage.

IMPORTANT

Indicates notes which we ask you to observe.  The safety precautions in this instruction manual are the mini-

mum necessary conditions.  Follow national and local regulations regarding fire prevention, electricity and 

safety as well as your own company regulations.

Model

Nozzle orifice

Air cap 

Fluid output

Air consumption

*Pattern width

Mass

ø mm (in)

set

ml/min

l/min (cfm)

mm (in)

g (lbs)

TOF-6 / TOF-5 / TOF-6R / TOF-5R Pressure feed

Fan

Round

Fan

Round

TOF-5/5R - 05
TOF-6/6R - 05
TOF-5/5R - 10
TOF-6/6R - 10
TOF-5/5R - 13
TOF-6/6R - 13
TOF-5/5R - 20
TOF-6/6R - 20

0.5 (0.02)

1.0 (0.04)

1.3 (0.05)

2.0 (0.08)

05

60

60 (2.1) 40 (1.4)

50 (1.8)

55 (1.9)

85 (3.0)

250 (9.8)

350 (13.8)

400 (15.7)

200 (7.9)

70 (2.8)

80 (3.1)

90 (3.5)

50 (2.0)

80 (2.8)

100 (3.5)

140 (4.9)

250

360

600

10

13

20

350 

(0.77)

Measuring conditions

: Tested with water at 3.0 bar.

* Spray distance 300 mm

ANEST IWATA Italia S.r.l.

46, Corso Vigevano 10155, Torino (Italy

)

Tel. d39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
[email protected]

www.anest-iwata.it

ANEST IWATA Iberica

Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 933 20 59 93 - Fax.:+34 933 20 59 65
[email protected]

www.anest-iwata.es

ANEST IWATA Europe S.r.l.

NIEDERLASSUNG DEUTSCHLAND
Dorfäckerstr. 23/1, 74248 Ellhofen
Telefon: +49 (0) 7134- 917368 - Fax: +49 (0) 7134 - 917378
Handy: +49 (0) 172 - 62 74 542
[email protected]

www.anest-iwata.de

ANEST IWATA Europe S.r.l.

46, Corso Vigevano 10155, Torino Italy
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 406
[email protected]

www.anest-iwataeu.com

ANEST IWATA Scandinavia 

Ögärdesvägen 6C, 433 30 PARTILLE - Sweden 
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
[email protected]

www.anest-iwata.se

ANEST IWATA France 

25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
[email protected]

www.anest-iwata.fr

ANEST IWATA  U.K.

Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH 
Tel.: +44 (0) 1480 405419  Fax: +44 (0) 1480 217610
[email protected]

www.anest-iwata.co.uk

European Sales Branches:

*Measuring point: 1m backwards from gun, 1,6 m height

Reviews: