background image

 

 

 

 

 

A m e r i c a n   C h a n g e r 

 

1400 NW 65

TH

 Place  

  Ft. Lauderdale, FL  33309 

 

 

 

 

 

 

 

 

 

        

 

 

 

 

CLASSIC SERIES – CHANGER

 

 

OPERATIONS MANUAL 
MODELS AC2002/2002.1

  

 

ARL Listed STD:  UL 756 

 
 
 

 

 

 

 

 

Parts & Service:  (888)741-9840 

Service Fax:  (954)917-5204 

   

 

 

 

 

 

Sales:  (800)741-9840

 

 

 

 

 

To order parts only, visit our website:   

www.americanchanger.com

 

Service Questions?  E-mail

:

   

[email protected]

 

 

 
 
 
 

Revised October 2009 

Summary of Contents for AC2002

Page 1: ...ERIES CHANGER OPERATIONS MANUAL MODELS AC2002 2002 1 ARL Listed STD UL 756 Parts Service 888 741 9840 Service Fax 954 917 5204 Sales 800 741 9840 To order parts only visit our website www americanchan...

Page 2: ...2 Model Number ________________________ Serial Number ________________________ Tested By ________________________ Date ________________________...

Page 3: ...ranty work It is the end users responsibility to follow cleaning and maintenance procedures as outlined in the validator manual Any unit returned for repair requiring only a cleaning will be charged a...

Page 4: ...11 Wire Harness Color and Definitions 11 Hopper Coin Token Sizes General Information 12 Validator Interface 12 Main Logic Board Connector Pin Definitions 13 Functional Description of the Series AC2002...

Page 5: ...ER FOR YOU 1 Disconnect any and all AC power going to the changer Unplug AC line cord from the Power Module Board and from the wall 2 Slide the hoppers out of the cabinet 3 Note You will need to verif...

Page 6: ...e Filling the Hoppers section 16 In order to continue you will need to purchase electrical cable conduit a standard 3 prong AC wall outlet and 12 gauge wire We highly recommend hiring a licensed elect...

Page 7: ...red LED numbers are not counting up rapidly on the Main Logic Board s display the dump mode was not accessed Please try again The Dip Switches The AC2002 changer is capable of dispensing coins in man...

Page 8: ...8 HOPPER PAYOUT TABLE...

Page 9: ...9...

Page 10: ...trols the right hopper s payout Refer to the next table to set up your changer for the settings you need Mode Descriptions Some of the modes are self explanatory while others have sub modes built into...

Page 11: ...ce Hopper error detected Validator Logic Board 1 Red LED a On Steady Standby Mode waiting for bill insertion b Flashing Error mode go to page for error code information c Off The changer Empty LED is...

Page 12: ...r Validator Interface Interfacing for all MDB Validators No Dip Switches Validator can be factory programmed or it can be configured using the Configuration Card or a Palm Refer to the validator s Ins...

Page 13: ...per second in the standby mode 2 During the power up mode the main logic board relay clicks twice enabling power 120VAC to the validator When this relay is not enabled it routes 12VDC ground to the o...

Page 14: ...our own call your distributor or return the defective hopper to American Changer b Indications for a blocked coin optic or bad hopper logic board are that the out of service LED on the outside of the...

Page 15: ...male socket s pins so that they are not so spread out 2 If the continuity is infinity then replace that hopper QUICK CODE ERROR DEFINITIONS Figure 5 MAIN LOGIC BOARD on back wall of cabinet Press the...

Page 16: ...16 Dual Hopper Schematics...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ard on Yes NO Is the On Off I O switch on I pressed down Yes Is the 120VAC plug pushed into the bottom of the logic board and into the wall Yes Using a meter check the 2 amp fuse Is it good good Yes N...

Page 21: ...ins 2 and 7 3 Clean the gold contact plates with steel wool 4 Perform the following steps a Turn the changer off b Ensure that the left hopper plate red connector on the left side of the main logic bo...

Page 22: ...1 Ensure the dip switch settings are still correct 3 ON only 2 Check the continuity of the brown and purple wires on the hopper s wire harness 3 The hopper is jammed 4 Replace the hopper s wire harne...

Page 23: ...the area behind the push bar with high pressure or canned air Concentrate on the encoder wheel in the area top center behind the push bar 2 Contact American Changer technical service 888 741 9840 to r...

Page 24: ...24 Maintenance Information A full size version of the cleaning kit instructions is included in your information packet...

Page 25: ...9 AC9021 PYRAMID 110V BILL VALIDATOR 10 AC1042 HOPPER EXTENSION CAPACITY 1200 COINS EACH 11 2900 MANUAL PACKET 12 2010 104 LEFT STAINLESS COIN DIVERTER ONLY 13 2010 114 RIGHT STAINLESS COIN DIVERTER O...

Reviews: