background image

MG 405
DB 531.3 (GB) 05.00
Printed in Germany

Operating Instructions

for On-Board-Computer

Error

km/h

1/min

123 3

0

I

km/h

+1

+

10%

10%

kg/ha

ha

100%

ha

_

1/min

MOD

m

Imp.

Cal.

kg/

ha

1

40

100 m

Start

C

+

_

Eingabe

Input

Σ

STOP

Before starting to operate,
please carefully read and

adhere to this operation manual
and safety advice!

GB

Summary of Contents for AMADOS-II

Page 1: ...structions for On Board Computer Error km h 1 min 123 3 0 I km h 1 10 10 kg ha ha 100 ha _ 1 min MOD m Imp Cal kg ha 1 40 100 m Start C _ Eingabe Input Σ STOP Beforestartingtooperate please carefully read and adheretothisoperationmanual and safety advice GB ...

Page 2: ...All rights reserved On receipt of the compouter On receipt of the computer please check whether transport damage has occured or whether any parts are missing Only immediate claims to be filed with the forwarding agency may lead to replacement Please check whether all parts mentioned in the following are provided ...

Page 3: ...ng system consisting of 1 Basic unit AMADOS II consisting of Computer Console Battery connecting cable with plug and fuse 16A at random 2 Sensor X for fitting to wheels and cardan shafts consisting of Sensor X cardan shaft wheel Universal mounting kit for Sensor X cardan shaft wheel Complete with 6 magnets 6 brass bolts with nuts and washers Mounting clamp with magnet 27 51 Mounting clamp with mag...

Page 4: ...g the start function 18 3 1 4 2 Changing the spread rate during fertilising operation 18 3 1 4 3 Spreading extremely small spread rated e g green manure seed and slug pellets 18 3 1 4 3 1 Special case spreading rye grass 18 3 1 4 4 Function keys and their use during the spreading operation 20 3 1 4 4 1 Forward speed k p h 20 3 1 4 4 2 Hectare meter 20 3 1 4 4 3 Part distance counter 20 3 1 4 3 Pto...

Page 5: ...are meter 57 3 3 1 In General 58 3 3 1 1 AMADOS II on off switching 58 3 3 1 2 Dial implement specific data values 58 3 3 2 Putting to operation short instruction 58 3 3 3 Preparations for starting the operation DETAILED INSTRUCTION 59 3 3 3 1 Enterings regarding the implement type mode 1 59 3 3 3 2 Entering the implement specific data 59 3 3 3 2 1 Entering the working width 59 3 3 3 2 2 Calibrati...

Page 6: ...ata are available again 1 3 Function description AMADOS II is supplied with a 6 digit display 1 1 1 In operationg position of the corresponding machine the display shows at centrifugal broadcaster current forward speed spread rate and shutter position opened or shut at the seed drill current seed rate tramline counter and marker position as a pure hectare meter the forward speed Atthelefthandedgeo...

Page 7: ...display of the actual switching rhythm and after having pressed this key an automatic advance of the tramline counter is avoided vacant position vacant position intermittent tramline ON vacant position vacant position increase seed rate increase seed rate vacant position reduce seed rate reduce seed rate vacant position return seed rate to rated value previously entered return seed rate to rated v...

Page 8: ...bration value vacant position input key for increasing the displayed value input key for increasing the displayed value input key for increasing the displayed value input key for decreasing the displayed value input key for decreasing the displayed value input key for decreasing the displayed value key used to confirm all entries key used to confirm all entries key used to confirm all entries corr...

Page 9: ...nt 2 2 Hint Symbol This symbol marks machine s specific pointswhichshouldbeobservedtoensure the correct operation 2 3 Declined use of the machine AMADOS II has exclusively been designed for the usualoperationasadisplay monitoring andcontrolling device for agricultural machinery Any use beyond the one stipulated above is no longer considered as designed use The manufacturer does not accept any resp...

Page 10: ...531 3 05 00 10 Centrifugal broadcaster Fig 3 1 braun blau 12 V Error km h 1 min 123 3 0 I km h 1 10 10 kg ha ha 100 ha _ 1 min MOD m Imp Cal kg ha 1 40 100 m Start C _ Eingabe Input Σ STOP 5 3 9 4 6 7 7 1 2 16A 8 8 ...

Page 11: ...rev speed sensor If the rated value is exceeded or undercutbymorethan10 anaudiblealarmsounds off and simultaneously the display changes alternativelyfrom operationdisplay to faultdisplay please see para 3 1 4 3 AMADOS II in the main consists of Fig 3 1 1 Calculator 2 Base console with mounting bracket 3 3 Mounting bracket 4 Battery power supply cable 5 Sensor X cardan shaft wheel for determination...

Page 12: ...tching on the display briefly shows the creation date of the computer program Always ensure that the servo motors set the setting levers nearly into the range of the zero position do not mind scales Whenever the supply voltage drops to below 10 volts e g when starting the tractor the computer automatically switches off It has to be switched on again as described above 3 1 1 2 Dial implement specif...

Page 13: ...hon AMADOS II pls refertopara 3 1 1 1 Initially the display shows the program entering date For the following period of approx 10 sec then no entry is possible Thereafterautomaticallythe errormessage 13 is shown After a waiting time of approx 15 seconds the mode 1 can be dialed Display with wrong coding Error km h 1 min 2 Mode 1 Choosing the machine type press and dial Mode 1 By actuating the MOD ...

Page 14: ... once again 100 key to check the stored value On the display then the figure 500 should appear Duringfertilisingoperationthespread rate can be changed by the keys or in 10 steps At spread rates of more than 1000 kg the first digit is not shown 3 1 3 2 2 Enter working width For determining the operated area AMADOS II requiresinformationabouttheworkingwidth Theworking width should be entered as foll...

Page 15: ...osen value will be stored press once again key to check the stored value Thedisplayshouldthenshowthedialedvalue In case of deviations between theactuallyspreadrateandtheactually worked area the displayed area determined by AMADOS II and the actual worked area newly determine the calibration figure by driving along a calibration distance of 100 m please refer to para 3 1 3 2 3 point 2 I 2 The value...

Page 16: ...splay now shows the shutter opening time After at least 30 seconds close the shutter After closing the shutter the display changes Display after closing the shutter Error km h 1 min 3 1 3 2 4 Fertiliser calibration The broadcaster can only then be set to spread accurately when the fertiliser properties especially the flowing behaviour are exactly known Thisflowingbehaviourmayalreadychange after a ...

Page 17: ...hefertiliserandworkingwidthused which can be called up on the display by pressing the key After completing the calibration test reinstall the spreading disc Howtoconductthecalibrationtestwhentheentered spread rate exceeds the maximum spread rates mentioned in table 3 1 Example Working width 24 m Wanted spread rate 1300 kg ha Thusthemaximumallowablespreadrateforconducting the calibration test for 2...

Page 18: ...nt position fault message 3 1 4 2 Changingthespreadrateduringfertilising operation During fertilising operation the spread rate can be changed by the keys or in 10 steps In the event of a drastic change of application rate for more than 50 it is advisable to carry out a fresh fertiliser calibration 3 1 4 3 Spreading extremely small spread rated e g green manure seed and slug pellets Spread rates b...

Page 19: ... 135 193 154 129 169 135 113 150 120 100 145 116 96 30 222 178 148 211 169 141 185 148 123 164 131 110 158 127 106 31 242 194 161 231 184 154 202 161 134 179 143 120 173 138 115 32 263 210 175 251 200 167 219 175 146 195 156 130 188 150 125 33 285 228 190 271 217 181 237 190 158 211 169 141 203 163 136 34 307 246 205 293 234 195 256 205 171 228 182 152 220 176 146 35 331 265 220 315 252 210 276 22...

Page 20: ...n Display after one time pressing the key Error km h 1 min 2 Hectare meter Total area After two times pressing the key Σ the total area in ha e g of one season is displayed Display after two times pressing the key Error km h 1 min 2 1 Setmemoryforhectaremeter totalareato 0 Set memory for the hectare meter total area via a reset to 0 Press and hold it pressed while pressing 0 release key Aresetwill...

Page 21: ...vant shaft shall notbemonitoredanylonger therev speed monitoring should be switched off 1 Theactualspeedbecomestheratedspeed Entering the rated speed Drive the shaft to be monitored with the desired rated speed e g 540 min 1 Press key and the actual speed is shown in the display If the shown speed is equal the rated speed press key and store this speed as rated value Switch off speed monitoring Sw...

Page 22: ...arly to the 0 position on the scale If an uneven emptying of the two hopper tips is noted a new calibration of the servo motors is required In this case please contact our technical service department I I I F 1 1 2 3 1 7 Operation in the event of electrical failure In the event of electrical faults occuring on the computer AMADOS II or the electrical servo motors the operation can be continued eve...

Page 23: ...adapt speed switch off AMADOS start fresh job see para 3 1 4 1 11 rated value not entered enter rated value see para 3 1 3 2 1 12 working width not entered enter working width see para 3 1 3 2 2 13 no reaction by servo motor check mode see para 3 1 3 1 check servo motor function e g by activating the discharge container functions see para 3 1 5 no area determ ination working width has not been ent...

Page 24: ...AMADOS II DB 531 3 05 00 24 Seed drill Fig 3 2 5 5 1 6 2 3 1 16A 7 14 10 4 15 9 8 11 12 13 ...

Page 25: ...et 4 Electric power cable 5 Small distributor KII with the movement sensor 6 andwiththeconnectingpossibilityofthesensoric formeteringshaft tramliningcontrol markerchange over pre emergence markers and seed level indicator 5 1 Large distributor GII with the movement sensor 6 andwiththeconnectingpossibilityofthesensoric formeteringshaft tramliningcontrol markerchange over pre emergence markers seed ...

Page 26: ...AMADOS II DB 531 3 05 00 26 Seed drill Fig 3 3 11 4 3 2 1 9 7 10 16A 5 5 1 14 8 15 10 6 13 12 ...

Page 27: ...r 2 Basic console with bracket 3 3 Bracket 4 Electric battery connecting cable 5 Small distributor KII Profi with the movement sensor 6 and with connecting possibilities of the sensoric for metering shaft tramlining control marker change over pre emergence marker and seed level indicator 5 1 Large distributor GII Profi with the movement sensor 6 and with connecting possibilities of the sensoric fo...

Page 28: ...nthementionedorder newly or check All data regarding implement type and implement execution Mode 1 to 6 may only be entered while the implement plug is disconnected 1 While implement plug is disconnected switch on AMADOS II pls refer to para 3 2 1 1 Initially the display shows the program entering date For the following period of approx 10 sec then no entry is possible Thereafterautomaticallythe e...

Page 29: ...or seed drills w i t h seed rate remote control regarding this please refer to para 3 2 3 2 9 Check Imp 100m and correct if necessary by direct entering of by calibration test run see para 3 2 3 3 1 10 Check the working width and correct if necessary see para 3 2 3 3 2 11 Enter rated value for the seed rate only for seed drill with seed rate remote control see para 3 2 3 3 3 12 Before starting the...

Page 30: ... drill is equipped with or without markers If the seed drill is equipped additionally with an electric seed rate remote control via AMADOS II the seed rate can be changed during the sowing operation The desired increment by which the change of the seed rate shall be conducted by pressing keys or will be determined via the chosen coding machinery type seed drill under mode 1 Press and select mode 1...

Page 31: ... up mode by actuating the MOD key Display after selectring Mode 3 Error km h 1 min 3 22 The first figure shows the selected Mode 3 the 22 says that at a permanent fault on the counter shaft a period of 22 seconds set by the factory will pass before an alarm is released Changethisperiodonlyafterhavingcalled on our technical field services Change wanted time via keys or Press key and thus store the ...

Page 32: ... with seed drills with seed rate reduction when creating tramlines i e pneumaticseeddrillswithseedrateadjustment without seed return flow Pre dial via the second figure the recommended seedratereductionin whencreatingtramlines The seed rate reduction depends on the working width of the seed drill the number of sowing coulters the number of tramline hoses The value for the second figure may be take...

Page 33: ... in the AMADOS II are eradicated implement specific data hectare meter etc Thisshouldespeciallybeconsidered when retrofitting a seed rate adjustment or when calling off the seed rate adjustment Before conducting a change imperatively write down all important data Press key and select mode 6 Count up the mode by actuating the MOD key Display after selecting Mode 6 Error km h 1 min 6 01 The first fi...

Page 34: ...the two range gearbox keeppresseduntilonthedisplaythegearbox setting lever position 98 will be shown Press and the calibration procedure is terminated Compare the gearbox setting position shown on the display with the gearbox setting position on the scale of the two range gearbox see para 3 2 3 2 1 3 2 3 2 1 Compare displayed and actual gearbox setting lever position only on seed drills w i t h se...

Page 35: ... with the gearbox setting position on the scale of the two range gearbox Ifthe shownandactualsettingleverpositionstill does not coincide repeat correspondingly the calibration procedure Example 2 Thevaluefortheactualgearboxsetting leverpositionissmallerthanthatshown on the display shown gearbox setting lever position 50 actual gearbox setting lever position 49 How to conduct a new calibration proc...

Page 36: ...rmeningtheactualforwardspeed AMADOS II required the value Imp 100m which sensor X releasesto AMADOS II whendrivingdownacalibration distance of 100 m For entering the calibration value Imp 100 m two possibilities are given the value Impl 100 m is known and is dialed via the key board the value Impl 100 m is not known and will be determinedbydrivingdownapre measureddistance As the calibration figure...

Page 37: ...tar wheel Ø 1 18 on the star wheel Ø 0 65 on the intermediate drive on the gearbox on the star wheel on the intermediate drive Working width m 1 40 ha 2 5 27 0 59 0 27 0 59 0 3 0 22 5 38 5 49 0 67 5 22 5 49 0 4 0 17 0 37 0 50 5 17 0 37 0 4 5 15 0 33 0 45 0 15 0 33 0 6 0 24 5 34 0 gearbox Sensor fixed to FPS FRS AMADOS Impulses 100 m 1053 1331 1175 1410 326 326 617 672 Tab36 doc D8 Special D8 Super...

Page 38: ...g the calibration distance 100 m Press key and this way store the displayed determined calibration figure Imp 100 m Press key once again and check the calibration figure The display should now show the determined calibration figure e g 1005 Imp 100 m Display of the determined calibration figure Enter the determined calibration figure into table 3 7 Table 3 7 Grounddependentcalibrationfigure Imp 10...

Page 39: ...h seed rate remote control The desired seed rate can only be entered on the machine stationary Press key 100 Dial the desired seed rate value via the keys or on the display e g 200 for 200 kg ha Press key and store the dialed value 200 Press key 100 once again and theck the stored value The display must then show the figure 200 Display of the seed rate value Error km h 1 min Conduct a calibration ...

Page 40: ... 50 on the display which is usual for the seed material to be sown preferedly for grain 50 and for rape 10 Display of the gearbox setting lever position Error km h 1 min Press key and store the entered value e g 50 On the display it should continue to read the figure 50 and the electric setting motor moves the gearbox setting lever on the scale at the two range gearbox into the position 50 Newly s...

Page 41: ...he new settingleverposition Theelectricsettingmotormoves the gearbox setting lever into this position If the fault message ERROR 1 is shown the desired seed rate is not achieved By changing the pinions in the two range gearboxthisfaultcanpossiblyberemedied Check this new gearbox setting lever position by a new calibration test Repeat this procedure as longasthecollectedandtherequiredcalibrationrat...

Page 42: ...automatic marker changeover Thevarioustramlinesystemsaredescribed in the seed drill s instruction book Example Seed drill 3 m working width Fertiliser broad caster Field sprayer 24 m working width 24 m tramline spacing Pleaselookupthechapter meteringwheel tramlining control of the seed drill s instruction book Table 3 8 Extract of the instruction book seed drill A Working width of the seed drill B...

Page 43: ...he chosen switching rhythm The second flicking figure 4 shows the actual position of the tramline counter Preselect the required switching rhythm e g 8 via the keys or Press key and store the pre selected value 8 Thereafter the following display is shown Display with newly entered switching rhythm Error km h 1 min 8 0 Press key STOP once again so that the second figure 0 stops flicking Table 3 9 s...

Page 44: ...7 18 r h 18 l h 19 r h 19 l h 20 21 22 23 24 25 26 1 0 0 1 1 1 1 0 0 0 0 1 1 0 2 1 1 2 2 2 2 1 0 0 0 0 R 0 R 1 3 2 2 3 0 0 3 2 1 1 1 3 3 2 4 3 3 4 4 4 4 3 2 2 2 0 L 4 3 5 4 4 5 5 5 5 4 3 3 3 5 5 4 6 5 5 6 6 6 6 5 4 4 4 6 0 L 5 7 6 6 0 0 0 0 6 5 5 0 L 7 6 8 7 7 8 8 8 8 7 6 6 8 8 7 9 8 8 9 9 9 9 8 7 0 R 0 L 8 10 9 9 10 10 10 10 9 8 10 10 9 11 10 10 11 11 11 11 11 10 12 11 11 0 0 0 0 12 13 12 12 13 1...

Page 45: ...or km h 1 min 04 10 When the interval tramline had been switched on the triangular symbol is shown above the interval tramline symbol F Procedure for creating interval tramlines Press keys Now the interval tramline switching has been switched on and on the display are shown two figure blocks separated by three points e g 4 10 The figures say that when creating tramlines sown areas of 4 m and areas...

Page 46: ...he seed drill has been lowered into operational position and is being pulled across the field At every track marker change a honking signal sounds 3 2 4 2 Shifting on tramline counter For the correct creation of tramlines the tramline counter should be advanced prior to starting the operation via key 1 and select this way the figure which under the word START is shown for this please see para 3 2 ...

Page 47: ... is interrupted or when folding the track markerduringthesowingoperation Stop key If becomes necessary to interrupt the sowing operation on seed drills without track marker because of stopping in the field because the seed drill is lifted e g when giving way to obstacles or when it becomes necessary to fold the track markers on seed drills with track markers e g for giving way obstacles unconditio...

Page 48: ...ol is switched on Marker r h in operational position only D8 AD MD8 1 min The wanted rev s are exceeded or undercut by more than 10 Seed box is empty Error Error 1 means error in gearbox position Error 2 means error metering shaft Error 3 means error counter shaft r h Error 4 means error counter shaft l h Error 5 means setting motor does not react Marker l h in operational position only D8 AD MD8 ...

Page 49: ... key Σ the covered part area in ha is displayed which has been covered since actuating the start function Onlythecoveredareawillbedeterminedat which the fertiliser broadcaster had been in operating position Display after one time pressing the key Error km h 1 min I 2 Hectare meter Total area After two times pressing the key Σ the total area in ha e g of one season is displayed Display after two ti...

Page 50: ...danylonger therev speed monitoring should be switched off 1 Theactualspeedbecomestheratedspeed Entering the rated speed Drive the shaft to be monitored with the desired rated speed e g 540 min 1 Press key and the actual speed is shown in the display If the shown speed is equal the rated speed press key and store this speed as rated value Switch off speed monitoring Switch off monitoring of the spe...

Page 51: ... setting rated value too high reduce rated value see para 3 2 3 3 3 new calibration see para 3 2 3 2 2 fault at metering wheel shaft check whether the metering wheel shaft is rotating 3 fault at countershaft right check whether the countershaft right turns 4 fault at countershaft left check whether the countershaft left turns 13 no reaction at servomotor check the mode see para 3 2 3 1 point 7 che...

Page 52: ...ensor When the seed box is emtpy the LED must not be illuminated Sensor is w o power LED does not light up when sensor is in contact with the seed Repair sensor cable or replace sensor Check cable in distributor box for secure fit Clean corroded cable connections Check supply cables with test lamp see cable diagram Sensor LED on the AMFÜME special option goes out when insufficient seed is availabl...

Page 53: ...or corrosion from solenoid until solenoid makes an audible connection Move solenoid within the slots of the cartridge Straighten out bent coupling Despite tramline counter 1 2 3 etc tramlines are being created Error 3 flashes Solenoid is drawn but does not move Remove dirt and corrosion Release solenoid Check solenoid leads with test lamp cables must be without current straighten out bent coupling...

Page 54: ...st set the motor at a position suitable for the seed used Then commence the physical test without starting the calibration process For the calibration test the motor is set on a suitable position Press Input and C simultaneously fresh start Subsequently press Cal kg per 1 40 ha and C simultaneously The calibration test can not commence The AMADOS fails to calculate the seed rate of 1 40 ha per kg ...

Page 55: ...AMADOS II DB 531 3 05 00 Seed drill 55 ...

Page 56: ...OS II DB 531 3 05 00 56 Hectare meter Fig 3 4 braun blau 12 V Error km h 1 min 123 3 0 I km h 1 10 10 kg ha ha 100 ha _ 1 min MOD m Imp Cal kg ha 1 40 100 m Start C _ Eingabe Input Σ STOP 1 5 3 2 7 4 6 16A ...

Page 57: ...he rated value is exceeded or undercutbymorethan10 anaudiblealarmsounds off and simultaneously the display changes alternativelyfrom operationdisplay to faultdisplay please see para 3 3 4 2 3 AMADOS II consists in the main of Fig 3 4 1 Calculator 2 Base console with bracket 3 3 Bracket 4 Battery power cable 5 Sensor X cardanshaft wheelforthedetermination of the distance travelled 6 Sensor Y for de...

Page 58: ... which are required for monitoring the connected machine always by pressing key 3 3 2 Puttingtooperation shortinstruction Before starting to operate enter the implement specific data by pressing the correspondingkeysinthementionedorder newly or check Conduct all enterings regarding the implement type only with a disconnected implement plug 1 While implementplugisdisconnected switchon AMADOS II pls...

Page 59: ...mode 1 can be dialed Display with wrong coding Error km h 1 min 2 Mode 1 Choosing the machine type press and dial Mode 1 By actuating the MOD key count up the mode Dipslay after MOD key has been pressed Error km h 1 min 4 Error km h 1 min 1 04 ThefirstdigitshowsthechosenMode 1 thesecond the coding for the chosen machine type 04 for hectare meter via the keys or dial code 04 on the display press ke...

Page 60: ...n value Imp 100m by keys or Dial the known value Imp 100m via the keys or Press key The dialed value will be stored Press key once again and check the stored value Thedisplayshouldnowshowthedialedvalue 2 The value Imp 100 m is unknown Accurately measure a test distance of 100 m in the field Mark start and end point of the test distance 100 m 0 m Bring tractor with the implement to the start positi...

Page 61: ... 0 If now the machine fitted to a tractor is being brought to theoperationposition thedisplqaywillshowthepresent forward speed Operating display Hectare meter Error km h 1 min 6 9 forward speed shows up when the machine is in operating position vacant position vacant position vacant position vacant position flashes in the event of speed sensor impulses if an additional rev monitoring sensor is ins...

Page 62: ... Σ the covered part area in ha is displayed which has been covered since actuating the start function Onlythecoveredareawillbedeterminedat which the fertiliser broadcaster had been in operating position Display after one time pressing the key Error km h 1 min 2 Hectare meter Total area After two times pressing the key Σ the total area in ha e g of one season is displayed Display after two times pr...

Page 63: ... shaft shall notbemonitoredanylonger therev speed monitoring should be switched off 1 Theactualspeedbecomestheratedspeed Entering the rated speed Drive the shaft to be monitored with the desired rated speed e g 540 min 1 Press key and the actual speed is shown in the display If the shown speed is equal the rated speed press key and store this speed as rated value Switch off speed monitoring Switch...

Page 64: ...paint from the fitting surfaces Fit the bracket 4 1 3 fitted to the AMADOS II onto thetubeoftheconsole bringittothedesiredposition and fix by the thumb bolt there 4 2 Battery connection lead Connect the battery connection lead 4 1 4 for the power supply directly with the tractor battery 12 V and lay cable Connectcableconnector 4 1 5 withfuse 5A to brown cable and connect with the plus pole of the ...

Page 65: ...ttery connecting cable power 2 Implement socket DIN 9680 3 Mass groundcable forguidingoffanystaticcharge 4 Connector 5 Plug 36 poles 6 Cable leads to the distributor Connecting example Tractor execution for AMADOS II for Airstar Avant Fig 4 1b 1 Battery connecting cable 2 Distributor for providing AMADOS II with two sockets DIN 9680 for AMADOS II and light with switch with electric power 3 Switch ...

Page 66: ...solenoid with the supplied stainless steel screws onto iron The painted side of the solenoids should be visible The sensor should in minimum protrude 25 mm above the bracket 4 3 1 Fitting Sensor X cardanshaft wheel for recording the travelled distance If the tractor electronics already offers the possibility of an on board forward speed recording thespeedsignalsfor AMADOS II can be taken from the ...

Page 67: ...e sensor cable in such a way that it will notbedamagedfromsteeringmovements 4 3 1 2 Fitting to tractors with 4 wheel drive or MB trac Fit magnet 4 4 1 with hose clamp 4 4 2 to cardan shaft Fit magnet only to such a place on which no angle movements of the cardan shaft occur Fix sensor 4 4 3 with universal bracket 4 4 4 opposing magnet to the vehicle frame Spacing between magnet and sensor to be se...

Page 68: ...h shaft speed monitoring consists of Sensor Y 4 5 1 operatingposition withcable Y 4 5 2 and 39 pole machine plug 4 5 3 and sensor A 4 5 4 shaft speed with cable A 4 5 5 4 magnets incl fixing material hoseclampforfixingthemagnetsfortheshaftspeed monitoring cable tie and 2 brackets for fixing sensor Y and sensor A The connecting unit AMADOS II as a hectare meter with shaft speed monitoring is requir...

Page 69: ...ational position the vertical arrow lights up in the left hand edge of the display Ifthe implementparttowhichthemagnets are fitted is moving from the operational position by more than 40 mm from the sensor then for an unmistakeable recognition of the working position a se cond magnet should be fitted in the direction of movement of the magnet Fig 4 7 If the machine is in transport position the mag...

Page 70: ... the aid of the hose clamp 4 8 3 fixed to the shaft Whenfittingwiththeaidofthehoseclampbothmagnets with enclosed rivets and washers should be riveted onto the hose clamp Place holes in such a way that the magnets are positioned opposingly Red painted sides of the magnets should face in direction of the sensor Fitsensorwithenclosedbrackettoafirmmachinerypart opposing the magnet Thegapbetweenthemagn...

Page 71: ...onds _____________ Mode 4 do not change set by the fctory on 22 seconds _____________ Mode 5 Seed rate reduction when creating tramlines for pneumatic seed drills without seed return flow _____________ For pneumatic seed drills with seed return flow or for mechanical seed drills dial for the second figure 00 _____________ Mode 6 seed rate remote control yes 01 no 00 _____________ Working width m _...

Page 72: ...h 51 D 49202 Hasbergen Gaste Germany Branch factories at D 27794 Hude D 04249 Leipzig F 57602 Forbach Subsidiaries in England and France Factories for Fertiliser broadcasters storage halls handling systems Seed drills Soil cultivation machinery Field Boom Sprayers Municipal machinery H DREYER GmbH Co KG ...

Reviews: