CCTV Rack Mount Power Supplies

Installation Guide

Models Include:

Vertiline8

Vertiline8D

- 24VAC or 28VAC @ 5 amp

- 24VAC or 28VAC @ 5 amp

- Eight (8) fuse protected outputs

- Eight (8) PTC protected outputs

Vertiline83

Vertiline83D

- 24VAC or 28VAC @ 10 amp

- 24VAC or 28VAC @ 10 amp

- Eight (8) fuse protected outputs

- Eight (8) PTC protected outputs

Rev. 031808

More than just power.

TM

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Vertiline8

Page 1: ...ertiline8D 24VAC or 28VAC 5 amp 24VAC or 28VAC 5 amp Eight 8 fuse protected outputs Eight 8 PTC protected outputs Vertiline83 Vertiline83D 24VAC or 28VAC 10 amp 24VAC or 28VAC 10 amp Eight 8 fuse protected outputs Eight 8 PTC protected outputs Rev 031808 More than just power TM ...

Page 2: ...ated master power disconnect circuit breaker to the ON position Fig 3 pg 6 6 Select 24VAC or 28VAC power output for cameras 1 8 with the corresponding voltage adjustment switches Fig 1b pg 4 7 Measure output voltage before connecting cameras This helps avoid potential damage All terminals with common suffix P 1P 2P are the same polarity 8 Set illuminated master power disconnect circuit breaker to ...

Page 3: ...Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1 8 is blown Fig 1d pg 4 To restore the power output for Vertiline8 or Vertiline83 1 Switch corresponding output voltage switch to the OFF position Fig 1b pg 4 2 Eliminate the trouble condition 3 Replace the corresponding automotive blade fuse 4 Switch output voltage switch to the 24VA...

Page 4: ...cators 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade fuses Vertiline8 Vertiline8D Vertiline83 or Vertiline83D front Vertiline8 or Vertiline83 rear Vertiline8D or Vertiline83D rear Vert...

Page 5: ...Vertiline8 5 Fig 2 AC POWER Main Fuse 1 8 1 2 3 4 5 6 7 8 N P N P N P N P N P N P N P N P 1 2 3 4 5 6 7 8 28VAC OFF 24VAC OFF RESET Typical Hookup ...

Page 6: ...d Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral tria...

Page 7: ... of rack chassis Fig 4a 2 Install mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 4b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 4c Fig 6 Fig 5 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 6 2 Place unit in desired locatio...

Page 8: ...esponsible for any typographical errors Altronix Corp 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline8Series J10H Notes ...