Model:

 

QC2-3 
QC2-20 
QC2-40 
QC2-100 
QC2-100 reMote

• InstallatIon

• operatIon

• MaIntenance

QC2-100

(

shown

 

with

 

roll

-

in

 

cart

)

QC2-40

QC2-20

QC2-3

Q u i c k c h i l l e r

Summary of Contents for Quickchiller QC2-100

Page 1: ...U S A CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com Consult instructions for operation and use MN 36580 Re v 2 01 16 p r i n t e d i n u s a Model QC2 3 QC2 20 QC2 40 QC2 100 QC2...

Page 2: ...n Operation 18 Touch Screen Menus 18 Chill Using Preset Recipes 19 Chill Modes 20 Professional Mode Chill 21 Professional Mode Hold 22 Downloads 23 Settings 25 Service 27 Error Codes 27 Error Messages...

Page 3: ...res other than those indicated in this guide to use and clean the appliance is considered inappropriate and may cause damage injury or fatal accidents in addition to invalidating the guarantee and rel...

Page 4: ...ur staff to avoid the risk of accident or damage to the unit Operators must also receive regular safety instructions Any troubleshooting guides component views and parts lists included in this manual...

Page 5: ...owly Escaping hot vapors or steam can cause serious injury or death aDDItIonal safety proceDures anD precautIons If your gas appliance is installed under an exhaust hood the hood must be switched ON w...

Page 6: ...rbroilers or any other equipment producing grease laden air heat producing equipment such as ovens and ranges and steam discharging equipment such as steamer ovens and kettles Do not locate the Quickc...

Page 7: ...and positive seal around the entire door frame Refrigeration QC2 100R Alto Shaam does not offer recommendations on maximum run sizes Best refrigeration piping practices should always be followed and...

Page 8: ...ht 17 5 8 447mm Front DRAINAGE QC2 3 QC2 20 QC2 40 Evaporator Pan no installation required QC2 100 One 1 Floor Drain 1 2 12 7mm diameter Drain It is recommended that legs be attached to the unit befor...

Page 9: ...ver 1 2 Remove screws from hinge 2 3 Remove metal cap 3 4 Insert flat screwdriver into slot and pry out 4 Rotate cam so that deep grove is positioned to the right for left hand hinge or left for right...

Page 10: ...quarts 28 5 liters full size pans gastronorm 1 1 Three 3 20 x 12 x 2 1 2 530 x 325 x 65mm refrigeration 40 oz R404a Refrigerant One 1 1 2 hp Condensing Unit 2 800 BTU s per hour at 5 F 21 C in the fr...

Page 11: ...5 liters full size pans gastronorm 1 1 Five 5 20 x 12 x 2 1 2 530 x 325 x 65mm full size sheet pans Nine 9 18 x 26 x 1 refrigeration 40 oz R404a Refrigerant One 1 3 4 hp Condensing Unit freeze mode 4...

Page 12: ...18 x 26 x 1 refrigeration 80 oz R 404a Refrigerant One 1 1 1 2 hp Condensing Unit freeze mode 5 880 BTU s per hour at 5 F 21 C chill mode 11 400 BTU s per hour at 20 F 7 C INSTALLATION s ite installa...

Page 13: ...p contact factory carton dimensions l x w x h 57 x 44 x 94 1448mm x 1118mm x 2388mm refrigeration 200 oz R 404a Refrigerant One 1 3 hp Condensing Unit freeze mode 11 300 BTU s per hour at 5 F 21 C chi...

Page 14: ...um volume maximum 300 quarts 380 liters Maximum Chilling Capacity Approximately 240 lb 109 kg maximum volume maximum 150 quarts 190 liters full size pans gastronorm 1 1 Forty 40 20 x 12 x 2 1 2 530 x...

Page 15: ...20 20e 20 20g 20 20mw and QC2 100 69 5 8 x 26 7 8 x 42 1 2 1769 x 683 x 1080mm 3 11 16 93mm vertical spacing between shelves 5016480 5017151 ci 60 plate trolley Fits 20 10e 20 10g 20 20mw and QC2 100...

Page 16: ...No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local codes W arnIng To prevent SERIOUS INJURY DEATH or PROPERTY DAMAGE All e...

Page 17: ...oth safety and product quality 2 Modified Cook Chill Operations where a significant portion of food is cooked for immediate service and a smaller portion of more labor intensive hot food items are pre...

Page 18: ...probe or probes inserted into the center of the food The cycle is automatically terminated when the center of the food reaches the probe sensing temperature set by the operator In units with multiple...

Page 19: ...to serving DOOR If the QC2 40 or QC2 100 door is opened during any running chill or freeze cycle the fans will disengage and a DOOR IS OPEN message will appear on the screen If the door is open for lo...

Page 20: ...e Defrost Duration Drip Time Factory Presets Screen Calibration Sleep Mode Professional Mode Recipes Home Probe Count Alarm Demo Mode E 10 E 11 P 10 P 20 P 30 C 10 C 11 E 80 E 84 E 83 E 53 E 54 E 66 E...

Page 21: ...Chill 14 F 38 F 38 F 2 Beef Hard Chill 14 F 38 F 38 F 3 Casserole Hard Chill 14 F 38 F 38 F 4 Chicken Breast Soft Chill 34 F 38 F 38 F 5 Chicken Whole Hard Chill 14 F 38 F 38 F 6 Duck Hard Chill 14 F...

Page 22: ...the default hold temperature found under the User Settings Use Hold Temp to hold chilled items at a refrigerated temperature hard chill To rapidly decrease the temperature of foods by internal produc...

Page 23: ...ngs 7 Enter desired time or temperature on number pad or touch to select factory default 8 Touch to enter or to return to settings screen 9 Touch to start the chilling process The screen will indicate...

Page 24: ...the Hold cycle The screen will indicate Chill Time The length of time the chiller is operating in the preset mode Chill Temperature The preset temperature Hold Temperature The air temperature inside t...

Page 25: ...d transfer is complete Pull the data stick out of the data port Note If USB is not found when download icon is touched a No USB detected message will display on the screen All data has been transferre...

Page 26: ...is in process When complete pull the data stick out of the data port Screen will return to Home screen Note Download cannot be done when QC2 is in chill mode Software Upgrade 1 Insert USB data stick i...

Page 27: ...defrost cycle The length of time can be adjusted by touching or to adjust defrost cycle time Probe calibration Touch The offset and the temperature will display for probe 1 top 2 middle and 3 bottom...

Page 28: ...ult setting is 10 minutes Use or to adjust the drip time within a range of 5 15 minutes Probes Touch to indicate the number of probes being used in the chiller 0 1 or 3 Factory Settings Touching will...

Page 29: ...l be highlighted if error is present HMI 01 01H ID 01 A5 FF FF FF FF RB 00 91 Cavity 0 F Probe 1 0 F Probe 2 0 F Probe 3 0 F Coil 0 F Door Defrost In 00 00 00 Defrost 0000 00 00 00 Drain Heater 0000 0...

Page 30: ...Amount of time without power Touch to clear display and stop audible signal 00 00 05 Power Outage If a power failure occurs the control will produce an audible signal every 10 seconds and the display...

Page 31: ...l pad or sanitizing solution recommended for food contact surfaces 3 Reattach the probes to the receptacles and place probes into the proper probe bracket 4 Wipe each probe with a disposable alcohol p...

Page 32: ...ork chops or meat patties should be chilled directly on the sheet pans on which they were cooked Cover the sheet pans with clear plastic wrap for chilling After chilling this type of product can be pl...

Page 33: ...ture for frozen food DO NOT OVERLOAD THE QUICKCHILLER FOR THE PROCESSING FUNCTION c h i l l i n g PAN C a p a c i t y CHART chiller model no pans standard pan sizes total weight gastronorm pan sizes t...

Page 34: ...s Waffles French Toast 2 to 3 each 4 oz 113 gm 48 Eggs 2 to 4 oz 57 to 113 gm 96 to 48 Breakfast Meats 2 oz 57 gm 96 Cooked Cereals or Grains 4 oz 113 gm 48 Fruit Compote 4 oz 113 gm 48 Meat Poultry F...

Page 35: ...rranty Always use the proper cleaning agent at the manufacturer s recommended strength Contact your local cleaning supplier for product recommendations cleanIng MaterIals Cleaning can usually be accom...

Page 36: ...G COMPOUNDS OR IMPLEMENTS Probe Cleaning Procedures 1 Remove all food soil from probes between loads and at the end of each production shift Wipe entire probe cable assembly and probe holding door bra...

Page 37: ...not ticking Control failure Replace control E 80 EEPROM error This error message indicates the control memory is not correctly reading user set values The Quickchiller will remain operational but the...

Page 38: ...4 5b CS 29822 Caster Assembly 4 CS 29822 3 Caster Non Locking Option 4 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 6 SC 29824 Bolt 1 4 20 x 3 5 Shoulder Bolt Hex Head 16 7 BT 29820 Electrical Mounting Bracke...

Page 39: ...4 25 Push In Press In 1 8 DR 29833 Door Hinged Left 1 9 HG 35736 Hinge Top Door Left Hand Channel 1 10 PI 35930 Hinge Pin 1 11 SC 29835 Screw 10x1 2 T H P 410 S S M4XG 1 Item Part Description Qty 12 H...

Page 40: ...tor Fan ESP OL75EM14 1 5 SC 29855 Bolt 10 24x5 Phillip Truss 19 6 BT 29847 Evaporator Coil Mounting Bracket 2 7 VA 29852 Valve 1 4 Ton R404 L T MOP 1 8 RE 29846 Coil Assembly 12x17 1 4 Blast Chiller 3...

Page 41: ...V 1 2 SW 29823 Pressure Switch 1 3 FI 29862 Dryer 1 4 Filter with 2nd 1 4 1 4 Service Valve King 1 5 VA 29863 Solenoid Valve 120V Coil 2 6 Compressor 1 7 Service Valve Suction 1 8 VA 29864 Valve Sporl...

Page 42: ...27 Power Supply 115V to 12VDC 1 3 CB 35746 Connector USB Panel Mount 1 4 PE 36160 Panel Overlay 1 5 PN 29932 Control Panel 1 6 CB 36571 USB Communication Cable w plug 1 7 CC 36418 User Interface Board...

Page 43: ...29969 Stainless Steel Side Rack Optional 2 13 5014889 Leg Assembly Set of 4 4 LG 29904 Leg 6 1 14 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 Item Part Description Qty 1 PR 35771 Probe Receptacle Assembly 1...

Page 44: ...r 1 3 PR 35771 Probe Receptacle Assembly 1 4 PR 36201 Probe Product 1 5 SN 33541 Sensor Air 1 6 PR 37483 Coil Sensor Defrost Sensor 1 7 PN 29943 Drip Pan 1 8 WI 35157 Wire 11 279mm Loop Drain Heater 1...

Page 45: ...ondensing Unit 3 4 HP LT R404A 120V 1 6 FI 29954 Filter Dryer 1 7 Compressor 1 8 BT 29951 Bracket Back Compressor Hold Down 1 9 RE 29966 Condensate Evaporator Pan includes Hold Down Bracket 1 10 EL 29...

Page 46: ...tion Qty 1 CC 36418 User Interface Board and Firmware 1 2 SC 29991 Screw 6 32x1 2 T H P 18 8 SS Philllips Truss 4 3 PE 36130 Panel Overlay 1 4 CB 35746 Connector USB Panel Mount 1 5 PN 29962 Control P...

Page 47: ...Qty 1 RE 35155 Coil Solenoid 120V 18Z7612 2 2 VA 29898 Valve Liquid Line Solenoid 2 3 RE 37503 Compressor 1 5 HP LO R404A 230V 1PH 1 4 RE 37506 Transducer Suction Pressure 929 0114 00 1 5 RE 37505 Si...

Page 48: ...p 60 Hz 1 2 PE 37484 Compressor Louver 1 3 BT 29950 Hold Down Clip 2 4 5014889 Leg Assembly Set of 4 4 LG 29904 Leg 6 1 SC 29824 Bolt 1 4 20 x 5 Shoulder 4 SC 29824 Leg Bolt 1 4 20 x 3 5 Shoulder Bolt...

Page 49: ...33541 Air Sensor 1 2 Air Sensor Mounting Bracket 1 3 Housing Refrigeration Enclosure 1 4 PR 37483 Coil Sensor Defrost Sensor 1 5 VA 29906 Valve Expansion 2 6 Drain Pan Evaporator 1 7 Clip Left Coil 2...

Page 50: ...nf o r ma tion Q C 2 4 0 DOOR 2 3 4 5 1 Item Part Description Qty 1 DR 36748 Door Assembly Left Hand 1 contact factory Door Assembly Right Hand 1 2 HD 29958 Handle Door 1 3 HG 36650 Hinge 1 4 HL 29840...

Page 51: ...MN 36580 Rev 2 01 16 Quickchillers 49 parts information Q C 2 4 0 pa n supports 1 Item Part Description Qty 1 SR 36881 Rack Pan Support 18...

Page 52: ...4 CB 36571 USB Communication Cable w plug 1 5 CU 29964 Capacitor 14MFD 440VAC 2 6 SC 29991 Screw 6 32 x 1 2 T H P 180 8 SS 08BC Phillips Truss SS 1 7 BU 33619 Plug 1 8 CC 29930 Control Panel Assembly...

Page 53: ...3 TE 35153 Tee Copper 1 2 x 1 2 x 3 8 ID 1 4 VA 29898 Valve Liquid Line Solenoid 2 5 TE 35154 Tee Copper 1 1 8 x 1 1 8 x 5 8 OD 1 6 EL 35152 Elbow Copper 1 4 Street 2 7 FI 29987 Filter Drier 1 8 VA 2...

Page 54: ...coIL 1 2 3 4 Item Part Description Qty 1 RE 29905 Coil Assembly 19x20 3 2 VA 29906 Valve Expansion 3 3 TE 35153 Tee Copper 1 2 x 1 2 x 3 8 ID 1 4 TE 29985 Tee Copper 1 2 x 1 2 x 1 4 ID 1 5 FA 29945 E...

Page 55: ...tion Qty 1 DR 29990 Door Assembly Left Hand 1 contact factory Door Assembly Right Hand 1 2 HD 26967 Handle Door LH 1 HD 26966 Handle Door RH 1 3 HG 36650 Hinge Adjustable 3 4 GS 29994 Gasket Compressi...

Page 56: ...p 1 3 PN 29842 Louver Panel 1 4 PN 29999 Panel Control Panel Assembly Left Hand 1 contact factory Panel Control Panel Assembly Right Hand 1 5 DR 29990 Door Assembly Left Hand 1 contact factory Door As...

Page 57: ...3 11 PR 35486 Probe Receptacle 3 Q C 2 1 0 0 NT Narrow Trolley l e f t h a n d d o o r s h o w n 1 10 11 5 3 4 2 9 7 8 6 Item Part Description Qty 1 RE 29983 Condensing Unit 3HP 208 230V 1 Phase 1 RE...

Page 58: ...tor USB Panel Mount 1 3 CB 35769 USB Communication Cable 1 4 PN 29999 Control Panel Left Hand 1 contact factory Control Panel Right Hand 1 5 LT 26968 Door Latch Left Hand 1 LT 26969 Door Latch Right H...

Page 59: ...ce or fifteen 15 months from the shipping date whichever occurs first The labor warranty period is one 1 year from the date of installation or fifteen 15 months from the shipping date whichever occurs...