background image

AFS-700 LED Follow Spot 

Installation & User’s Manual

Summary of Contents for AFS-700

Page 1: ...AFS 700 LED Follow Spot Installation User s Manual ...

Page 2: ...product improvement New materials production methods and design refinements are introduced into existing products without notice as a routine expression of the philosophy For this reason any current Altman Lighting product may differ in some respect from its published description but will always equal or exceed the original design specifications unless otherwise noted Version as of 28 September 20...

Page 3: ...r on may expose you to dangerous voltages and damage the device It is always recommended that a lock out tag device is installed on the appropriate circuit disconnect prior to beginning electrical work of any kind A qualified electrician must perform this installation WARNING Insulation between low voltage supply and control conductors is provided by basic insulation WARNING Refer to National Elec...

Page 4: ...pressed or implied and no representative or person is authorized to assume Altman any other liability with the sale of Altman s products For complete warranty terms and conditions please refer to our web site at www altmanlighting com Warranty Service In order to request warranty service you must receive a Return Material Authorization RMA number prior to return Return shipments must be visibly ma...

Page 5: ...me tem perature changes hazardous conditions or restricted ventilation It is a good practice to add sand bag weights by others over each leg of the tripod to steady the fixture when moved Figure 2 AFS 700 LED Follow Spot Tripod Fixture Movement The fixture simply secures to the tripod via the tripod mounting bracket with the provided hardware Step 1 Place tripod in a suitable location following th...

Page 6: ...ower and Data Connections on page 6 for details Up Button for menu control scrolling trough options WHITE RED GREEN DIMMER STROBE CTO IRIS FOCUS ZOOM PINK AMBER BLUE LT AMB LAV LAMP ON OFF Dimmer Slider for controlling intensity Lamp On Off turns on and off the LED source only Note does not affect any other operation of the fixture Color Filter Buttons for selecting color filters Note selecting tw...

Page 7: ... 20 ampères circuit protecteur Ne surchargez pas les circuits WARNING If the external flexible cable or cord of this luminaire is damaged it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent Connecting Power Units are powered via an AC input cable from 100 to 240VAC 50 60Hz and draw approximately 780 Watts of power Table 2 outlines the wir...

Page 8: ...his layout will allow one lead follow spot operator to control automated the functions of additional AFS 700 LED Follow Spot luminaires Note the control panel does not control the manual pan and tilt functions of the AFS 700 LED Follow Spot which requires an operator at every follow spot location To set up Step 1 Set all AFS 700 LED Follow Spot luminaires to DMX address Adr to 001 Step 2 Connect A...

Page 9: ... time hours after reset Led Temperature 000 C Current LED operating temperature Version X X Current fixture software version Personality Display Adjust Display Flipped OFF Display normal Display Flipped ON Reverses display 180 Back Light ON always on 10s off in ten seconds 20s off in twenty seconds 30s off in thirty seconds Selects display time out duration on display and the LEDs on controller Ir...

Page 10: ...creasing speed 128 159 Pulse opening increasing speed 160 191 Pulse closing increasing speed 192 255 Random strobing 3 Color Temperature CTO 000 063 Native white CCT 064 127 5600K 128 191 4500K 192 255 3200K 4 Color Presets 000 016 White no color filter 017 033 White Red split half tone color 034 050 Flame Red 051 067 Red Green split half tone color 068 084 Moss Green 085 101 Green Light Pink spli...

Page 11: ...t materials and hardware DMX512A network or local control via AFS 700 Controller 778 Watt Cool White Array 7600K See product specification sheet for details 7 13 LED arrays are rated for 50 000 hours of operation 100 to 240 VAC 50 60 Hz 6 48 A at 120VAC 3 38A at 230VAC Fans on Lamp Off 0 51A 120VAC 61 2 Watts 0 to 45 degrees C 32 to 113 degrees F with humidity of 5 95 non condensing 28dBa in idle ...

Page 12: ...ild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the AFS 700 LED Follow spot Luminaire These types of cleaners or solvents can permanently damage the optics or housings of the fixture If you h...

Page 13: ...tecting DMX data Unit is not set to proper DMX address check settings See Setting DMX Address from the Home Screen for more information Unit is not set to DMX mode See DMX Menu for more information Disconnect and reconnect DMX input cable Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See...

Page 14: ...Altman Lighting 57 Alexander Street Yonkers New York 10701 1 914 476 7987 Main 1 914 966 9180 Fax www altmanlighting com 2019 Altman Stage Lighting Inc ...

Reviews: