background image

A

LPHATECH 

T

ECHNOLOGIES

 s.r.o

 Jeremenkova 88, Praha 4, Czech Republic 

www.alphatechtechnologies.cz

 

  

 

 

Door Phone NUDV 

NUDV - 00 
NUDV - 01 
NUDV - 02 

NC - mod4 

NM - mod4 

NKLA 

 

 

 

Installation and Operating instructions

 

Summary of Contents for 212101

Page 1: ...ALPHATECH TECHNOLOGIES s r o Jeremenkova 88 Praha 4 Czech Republic www alphatechtechnologies cz Door Phone NUDV NUDV 00 NUDV 01 NUDV 02 NC mod4 NM mod4 NKLA Installation and Operating instructions ...

Page 2: ...with one or two buttons Further the whole system allows to be enlarged by NC mod4 and NM mod4 modules up to 64 buttons using the basic mechanical MK1 MK4 units The whole assembly can be completed with cover frame or rain protective canopy both under plaster and on plaster The guard is supplied from branch exchange line his features remind a loud telephone The basic features include the possibility...

Page 3: ... OVERVIEW 13 2 2 VISITOR AT DOOR 13 2 2 1 Guard without Keyboard 13 2 2 2 Guard with Keyboard 14 2 3 PERSON INSIDE OBJECT 15 2 3 1 Outgoing Call 15 2 3 2 Incoming Call 15 3 PROGRAMMING OF PARAMETERS 16 3 1 PROGRAMMING THROUGH PHONE 16 3 1 1 Entry to Programming 16 3 1 2 Programming of parameters 16 3 2 PROGRAMMING FROM PC PROGRAM NSET 17 4 DESCRIPTION OF PARAMETERS 18 4 1 DIRECT DIALING MEMORIES 1...

Page 4: ... 5 TECHNICAL PARAMETERS 30 5 1 ELECTRICAL PARAMETERS 30 5 2 MECHANICAL DIMENSIONS 30 6 TABLE FOR EASY PROGRAMMING 31 7 DECT DISTYBOX 33 7 1 DISTYBOX DESCRIPTION 33 7 2 DISTYBOX SIGNALING 33 7 3 DISTYBOX PROGRAMMING 34 7 4 LOG ON TO BASE STATION 34 ...

Page 5: ...ord from buttons at the door Possibility to connect a numerical keyboard this way that the guard can include 0 18 standard buttons Keyboard mode could be either direct dialing or dialing from memory Optional number of rings before taking an incoming call Optional time among button pressing by code entry Optional time of hanging up when the choice is repeated Optional time before choice start Optio...

Page 6: ...mbly with numerical keyboard and camera module The complete assembly consists similarly to UDV system of max 4 modules in column and max 3 columns side by side NUDV2 NUDV1 NUDV0 NC M mod4 Camera Fixing KPD2 rain Canopy2 Flanging frame2 frame 2 protective cover flush mounted flush mounted on plaster By flush mounted assembly the MK 1 to MK 4 boxes are used as well as with UDV system MK 2 NKLA keybo...

Page 7: ...3 Module Features 1 3 1 NUDV Basic Module The NUDV basic module is supplied in three variants with two NUDV2 buttons one NUDV1 button and without buttons type NUDV0 V1 x Fig 1 Rear view of basic module Fig 2 Rear view of setting parts in version V6 x ...

Page 8: ...ends on number of modules since it simultaneously serves feeding of lighting through visiting cards at max number of connected modules the demand will not exceed 300mA This source can be also used for feeding of lock s and then it is necessary to consider the electrical lock demand In practice the alternating feeder 12V 1A mostly meets these demands The connection of switch contact terminals is sh...

Page 9: ... next is necessity gain of trimmer MIC make smaller Procedure of setting trimmer SPK setting to maximum turn to the right trimmer MIC on minimum and at conversation connection subscriber speaking in building permanent talk trimmer MIC turning to the right until sound from speaker begins interrupt next gain teeny reducing moving round a slight amount left It shall everything be all right For newer ...

Page 10: ...or connection of other four buttons and current supply of lighting are further placed on module on following NM mod4 The NM mod4 module is always connected to previous in row starting with basic module NC mod4 The connection is not prepared and should be done by conductors see on figure 4 The flat cable connection is facilitated by connector locks preventing from rotation but to keep the connectio...

Page 11: ...er 48 The choice is entered by gradual pressing of buttons with digits Firstly the key symbol must be pressed to enter a password When pressing X the guard will hang up 1 3 4 Other modules Other modules extending the guard assembly are actually offered on www alphatech cz and can be ordered by phone or fax on number 420272103334 1 4 Installation of Guard Assembly 1 4 1 Installation on Plaster By i...

Page 12: ...humidity by switched heating no water condensation occurs on basic guard board which assures its reliable function 1 5 Change of nameplates The first step is dismantling of a fixing frame from module where we want to change a nameplate It can be executed by unscrewing of two screws under plastic covers on fixing frame When removing the fixing frame we can see two independent modules The front part...

Page 13: ...Pulse goes out Call glows Notice about call end 1275 glows Entry to programming from phone 850 glows Programming from phone mod 850 glows Parameter confirmation glows Entry to programming from PC 850 glows Programming from PC blinks Connection to line Reset 1275 850 1275 blinks Error anything if unsuitable 425 Empty memory no progr numb 850 1275 1700 2 2 Visitor at Door The all purpose guard funct...

Page 14: ...e visitor at door presses buttons in such combination that meet the preprogrammed code parameters 32 34 and the time among presses is not bigger than the set point parameter 53 then the guard will lift up and close the corresponding switch if set in m 1 or m 5 modes to the period given by parameter 36 event 38 Then it will hang up 2 2 2 Guard with Keyboard The guard with keyboard can also include ...

Page 15: ...ill send a notice about call end and the call may be extended by sign selection parameter 42 The telephone hanging up will end the call the exchange is sending a busy tone on guard s line and the guard also will hang up 2 3 2 Incoming Call The incoming call is the call from guard caused by person inside object After exchange number selection where the guard is connected the guard s line is ringing...

Page 16: ...g tone and the guard will come back to this state always after time expiration 5 seconds even you started to program anything When programming two types of parameters will occur Partly they are parameters with fixed length the majority of them they are then the programming is affirmed and the parameter is always recorded immediately after mandatory length fulfillment by acknowledge tone and partly...

Page 17: ...nect the NUDV to the line Line the guard with PC by KAB cable if PC serial port absent the USB COM reduction is to be used The guard will answer and LED light on the front panel will light Run the Nset program the guard will report the his conversion to PC programming mode viz chapter 2 1 page 13 After Nset program being run the guard is in this mode this status is indicated by LED light on front ...

Page 18: ...64 nn telephone number up to 16 digits we want to store To store other choice flags the assignment given in table is used The numbers stored in parameter 2 are the number of the second group or numbers of Night mode Neither basic setting nor settings per examples do not change or delete the stored numbers Note The switchover to Day Night mode remains set in guard even after line disconnection List...

Page 19: ... switch closing from buttons or keyboard 2 to 6 digits Total 6 passwords they are controlled by Day Night the combination is entered either by guard buttons first 10 buttons or from attached keyboard after pressing of key symbol The switch closing influences the set switch mode and Day Night switchover By setting of choice mode of 2 number groups the guard is permanently in DAY mode By password ch...

Page 20: ...if p 1 allowed or p 0 prohibited to control the switch during incoming call To prohibit the control during incoming call is important e g when using switch 2 in mode 1 for control of garage gate opening when the electronics opens the gate and the gate is closed by car passage Then the control from phone could undesirably cause the permanent gate opening not closed no car passage List of related pa...

Page 21: ...ist of related parameters 35 8 84 Parameter Value Meaning Basic Exam 1 Exam 2 44 xxxx service password 0000 0000 0000 xxxx service password for entry to programming List of related parameters 8 84 Parameter Value Meaning Basic Exam 1 Exam 2 45 dd command for DAY switching 11 11 11 46 nn command for NIGHT switching 10 10 10 dd command for DAY mode switching 2 digits nn command for NIGHT mode switch...

Page 22: ... is entered on keyboard by which the number of called person is stored memory number corresponds to button number with respect to Day Night switchover ATTENTION This parameter setting will sharply influence keyboard function List of related parameters 1 2 47 48 53 8 84 4 4 Time Parameters Parameter Value Meaning Basic Exam 1 Exam 2 51 q number of rings before guard call lifting up 2 1 2 q Number o...

Page 23: ... If the number is incomplete it is necessary to hang up X button and the dialing will be repeated dialing from memory if time following the first pressed button is longer than w time then the entry of memory number has to be repeated List of related parameters 1 2 32 33 34 47 48 49 8 85 Parameter Value Meaning Basic Exam 1 Exam 2 54 z time of hanging up when dialing repeated 2 2 2 z time sec for w...

Page 24: ...on among DTMF tones 5 100ms 5 100ms 5 100ms 59 f Flash duration 1 100ms 1 100ms 1 100ms 50 p pause duration interdigit gap 8 800ms 8 800ms 8 800ms t DTMF tone duration is determined per formula entered number 5 x 10 tone duration ms range 1 0 i e 60 150ms m gap duration among DTMF tones is determined per formula entered number 5 x 10 gap duration ms range 1 0 i e 60 150ms f Flash duration is deter...

Page 25: ...mbers in group 2 Night mode 83 basic setting only for parameters 3x only 3 84 basic setting only for parameters 4x only 4 85 basic setting only for parameters 5x only 5 The parameters 81 and 82 will execute deleting of all numbers stored in memories for buttons The parameters 83 85 will execute a selective basic setting only for parameters starting with 3 5 ATTENTION the deleting is non reversible...

Page 26: ... Basic Exam 1 Exam 2 6 z Switching off acoustic signalization 3 3 3 In default is status of Door phone signalling acoustically It can cause a problem of incorrect detection of tones by PBX By parametr z you can switch off this acoustic signalization The values are z 0 all signalling is switched off z 1 pick up and hang up tones are active only z 2 other tones active only except pick up and hang up...

Page 27: ... 43 g bb command for guard hanging up from phone 155 266 155 244 155 244 44 xxxx service password 0000 0000 0000 45 dd command for DAY switching 11 11 11 46 nn command for NIGHT switching 10 10 10 47 e mode of guard choice 1 1 0 48 c keyboard connection 0 0 1 49 o keyboard mode 0 1 0 51 q number of rings before guard call lifting up 2 1 2 52 d maximum call time 2 2 1 53 w time among button presses...

Page 28: ...setting executes 8 1 setting per exam 1 executes 8 2 setting per exam 2 executes 81 deletes all numbers in group 1 Day mode 82 deletes all numbers in group 2 Night mode 83 basic setting only for parameters 3x only 3 84 basic setting only for parameters 4x only 4 85 basic setting only for parameters 5x only 5 9 E N D ...

Page 29: ...TMF sign of call extension ρ ρ ρ hanging up from phone 1 2 55 66 55 44 55 44 service password 0000 0000 0000 switching to day mode 11 11 11 switching to night mode 10 10 10 guard choice mode Day Night Day Night 2 groups keyboard connection no no on 1 st place keyboard mode dialing memory numbers dialing number of rings of incoming call 2 1 2 max call time 2 min 2 min 1 min time among button presse...

Page 30: ...evel 4 a 6 dB 20 60 mA Tone choice sensitivity 40 dB 20 60 mA Sensitivity of tone detector 30 dB 20 60 mA Power supply of lighting through switches and heating 12Vss 2V 10 12Vst 2V Max consumption of lighting through and heating 300mA 12Vss Max voltage of switch contact 48V at I 1A Max current of switch contact 2A at U 30 V Operational temperature 20 to 50 C 5 2 Mechanical dimensions dimensions Hx...

Page 31: ...Number under button 6 Day 1gr 106 16 Number under button 7 Day 1gr 107 16 Number under button 8 Day 1gr 108 16 Number under button 9 Day 1gr 109 16 Number under button 10 Day 1gr 110 16 Number under button 11 Day 1gr 111 16 Number under button 12 Day 1gr 112 16 Number under button 1 Night 2gr 201 16 Number under button 2 Night 2gr 202 16 Number under button 3 Night 2gr 203 16 Number under button 4...

Page 32: ...en 1 and 2 switch closing sec 38 2 Tone pulse tone choice 1 0 41 1 Sign of call extension 42 1 Guard hang up from phone 1 431 2 Guard hang up from phone 2 432 2 Service password 44 4 Comm to DAY switching 45 2 Comm to NIGHT switching 46 2 Guard choice mode 1 0 47 1 Keyboard connection 0 1 2 3 48 1 Keyboard mode 1 0 49 1 Number of rings for ringing 51 1 Maximum call duration min 52 1 Time among but...

Page 33: ...t be energized to power supply and the guards to outputs of analogue line indicated on figure both outputs of analogue line are parallel The DistyBox300 contains an internal antenna allowing the connection of 300 m direct visibility and 50 m in building The DistyBox5000 can be fitted with an external antenna increasing the range to 6 km 7 2 DistyBox Signaling LED indication Time interval is 8sec s...

Page 34: ...oth 1 internal 2 external call 72 xxx Flash length xxx times 10ms 100ms 010 firm 210ms 90 reset and company setting bold presets all 91 reset and company setting bold log in parameters will be kept 92 0 1 autoreset 0 inactive 1 active every 24 hrs will end all transmissions and recall to base station Settings for use with guard 90 401 410 700 710 Internal call will be executed by ρρs where s is 0 ...

Page 35: ...e producer only will make the guarantee repairs Attach the description of claim reason proof of purchase and your exact address to the product The guarantee does not include mechanical thermal chemical and other damages caused by user s activities defects caused by natural disasters defects caused by repair or changes carried out by user or other unauthorized person willful damage of product incor...

Page 36: ... TECHNOLOGIES s r o Jeremenkova 88 140 00 Praha 4 Czech Republic VAT CZ27577350 Company is registered in the Commercial Register administered by the Municipal Court in Prague Section C Record 116886 Banking details Komerční banka account No 43 7671450207 0100 IBAN CZ0801000000437671450207 SWIFT KOMBCZPPXXX ...

Reviews: