APPLICATION

The VMH25 series video-intercom system allows  a
number of VMH25 series inside handset sta-
tions to communicate with one or more door entry stations
with (or without) a built-in camera. When used as a door
entry video-intercom system, the VMH25WH can view
the caller, speak with the caller, and activate an electric
door release (if required).

PROCEDURE

1. Read installation instructions for each unit to deter-

mine equipment location and installation method.

2. Install housings and wiring.
3. Install equipment.
4. Check wiring and connect. Observe all local

and national electrical codes.

5. Apply power and check system operation.

VMH25WH Series (Residential Type)

Video-Intercom Installation and Use

Instructions, used with the NH200A

System Intercom Amplifier Unit

HOUSING INSTALLATION AND

EQUIPMENT LOCATION

INSIDE HANDSET STATION(s)

Locate stations where needed at convenient speaking and
viewing height, about 4.5 feet (137 cm) from the finished
floor. Unit can be secured directly to the finished wall
surface or can be mounted over a single gang electrical
'gem' box or single gang electrical plaster ring.

DOOR ENTRY STATION(s)

Locate door entry station(s) at a convenient speaking (and
viewing) location at the building entry location(s). NOTE:
For best picture (video) quality DO NOT POINT
CAMERA INTO DIRECT SUNLIGHT!!!

SYSTEM TRANSFORMER(s)

The SS146 and SS106 system transformers should be
connected to accessible sources of 117 VAC, preferably
within 50' (15 meters) of the VRU system power supply
unit(s), but no closer than 3 feet (1 meter).

ELECTRIC DOOR OPENER (OPTIONAL)

The DO-001 (or equivalent 16VAC type) electric door
release is installed in the door jamb in place of the regular
door strike plate. It can be electrically operated by the
VMH25WH video handset station(s).

WIRING

INSIDE HANDSET STATIONS

Run 4 conductor #22AWG (common), RG59/U (com-
mon)  and 1 conductor  #22AWG (selective) cable from
video handset to video handset to the
central equipment location (where the VRU  and NH200A
units are found). Run 2 conductor #18AWG from each
video handset directly to the corresponding VRU
power supply unit. Additional cables may be used to serve
other monitors on other risers (lines). Cables may be
straight or twisted pair type and may be solid or stranded
conductors. Depending upon additional system options
and/or functions you may need to run additional wires.
Please consult the factory for more information. RG59/U
coax cable must be good quality, ALL COPPER, with
minimum 95% copper braiding. As with all systems, we
recommend running some spare wires, for future use.

Route cable away from AC power wiring, transformers,

Summary of Contents for VMH25WH Series

Page 1: ...t a convenient speaking and viewing locationatthebuildingentrylocation s NOTE For best picture video quality DO NOT POINT CAMERA INTO DIRECT SUNLIGHT SYSTEM TRANSFORMER s The SS146 and SS106 system transformers should be connected to accessible sources of 117 VAC preferably within 50 15 meters of the VRU system power supply unit s but no closer than 3 feet 1 meter ELECTRIC DOOR OPENER OPTIONAL The...

Page 2: ...tch handset to another location that is functioning and try again Check that entry station pushbutton is making contact by shorting out the two 2 wires on the back of the button 3 NO PICTURE AT MONITOR If screen is NOT LIGHTING UP check for approximately 16VDC at and terminals on monitor PC board VH250E or fluorescent lights light dimmers or other electrical devices Protectcablefromdamage Shielded...

Page 3: ...control potentiometer on VH250E or VH250P PC board and adjust as needed from approx 0 to 180 seconds Calibration is not exact so please check timing after re adjusting 8 MONITORS DO NOT TIME OUT AT ALL Check for shorts and or grounds on system Tempo rarily switch monitor with one from a functioning loca tion Check that entry station pushbutton is not stuck or shorted TemporarilyswitchmonitorPCboar...

Page 4: ...tail wires coming from terminals O and LL on the VH250E or VH250P P C Board The Black O wire must jump to terminal O on the handset and the Red LL wire must jump to terminal S on the handset or the monitor will not activate when the handset is signalled from the entrance station s ON ...

Page 5: ...using a PINHOLE type camera instead of the standard S T R type camera see the special camera installation and connection instructions found on page 8 and do not power as shown above 3 DO NOT CONNECT MORE THAN 10 MONITORS PER VIDEO RISER LINE 4 Observe all local and national electrical and building codes 5 All terminals connections shown may not be in the order that they appear on the equipment ...

Page 6: ...type camera see the special camera installation and connection instructions found on page 8 and do not power as shown above 3 DO NOT CONNECT MORE THAN 10 MONITORS PER VIDEO RISER LINE 4 Observe all local and national electrical and building codes 5 All terminals connections shown may not be in the order that they appear on the equipment Note For more information on the VDU 4 or when connecting mul...

Page 7: ... 10 MONITORS PER VIDEO RISER LINE 4 Observe all local and national electrical and building codes 5 All terminals connections shown may not be in the order that they appear on the equipment TYPICAL WIRING DIAGRAM FOR DUAL ENTRANCE SYSTEM WITH S T R STYLE CAMERA AND ONE 1 VIDEO RISER NO VIDEO DISTRIBUTORS AND 1 4 MONITORS Note For systems with more than two 2 entrances or other configurations please...

Page 8: ... IS SUPPLIED TO THE CAMERA USE A METER TO CHECK THE POLAR ITY OF THE NEWLY SPLICED CABLE BEFORE CONNECTING IT TO THE CAMERA THE CENTER PIN MUST BE POSITIVE USE ONLY THE SUPPLIED POWER SUPPLY POWER SUPPLY IS FOR INDOOR USE ONLY DO NOT REMOVE THE SERIAL NO STICKER AS THIS WILL VOID THE WARRANTY IF YOU ARE USING A PINHOLE STYLE CAMERA s IN PLACE OF THE STANDARD S T R STYLE CAMERA s CONNECT THE CAMERA...