Страница 1: ...olarSpeed East West facing landscape Headquarters Mijnwerkerslaan 33 3 B 3550 Heusden Zolder T 32 11 72 96 50 Dutch branch Gladsaxe 45 NL 7327 JZ Apeldoorn T 31 857 326 946 info allimex greenpower eu www allimex greenpower eu ...

Страница 2: ...e unit brackets rail protective rubber Set L profiles support End rubber Middle clamps and end clamps hexagonal socket screws M8 EXTRA PARTS Alignment tool Concrete base 12 kg impact anchor PP base Cable tray support Cable clips For PVC roofs we recommend rubber with an aluminium coating MOUNTING TOOLS Cordless drill Socket 8 Hex keys Screwdriver Hammer Chalk line Pebble stone bin ...

Страница 3: ...can be derived from any printing or setting errors BEFORE THE INSTALLATION Correcte assembly plate screws When assembling with a screwdriver The use of impact wrenches is prohibited When using a screwdriver the rotation speed may not exceed 1500 rpm The washer must be mounted perpen dicularly and not too hard but also not too little Follow all safety measures in accordance with the relevant guidel...

Страница 4: ...screws Fold the panel stop using a screwdriver Fold it further until it forms an angle of 90 to the mounting bracket Assembling base units Place the base units on a flat en stable roof surface Connect the base units by sliding the top of the rail of the first base unit into the connection piece at the back of the next base unit Fix by drilling 2 self tapping screws Ø6 5 or SS rivets into the pre d...

Страница 5: ...rom any printing or setting errors 2 ATTACH END RUBBER AT THE END OF THE ROW SolarSpeed end rubbers Plastic plugs Skip this step if you use concrete or PP bases Push the plugs into the predrilled holes of the connectors Attach the connectors onto the rail by pushing the plugs into the pre drilled holes INSTALLATION ...

Страница 6: ... the way into the rail of the previous base unit every 30 metres but not securing it with screws This means that the rows are still connected to each other which benefits the required ballast and there is also room for thermal expansion Align the rows according to the plan considering the length of the panels Tip To easily determine and keep the distance between the base units use and alignment to...

Страница 7: ...or pebble roof you must remove the planting and or pebbles where the concrete bases should be placed ATTENTION Concrete bases must be placed on all places as described above In the absence of one or multiple footings bases this could lead to serious stability problems Concrete base impact anchor Protective rubber Placement base units Once the Allimex concrete bases have been positioned correct ly ...

Страница 8: ... holes provided in the rail of the base unit In principle protective rubber is not necessary as the PP support is also compatible with PVC roofs If the customer still wishes to have an additional rubber protection under the PP support this can be attached to the underside of the support with plastic plugs Due to the continuous development of our products a deviation on the image is possible No rig...

Страница 9: ...tronger ATTENTION If possible try to position the ballast tiles as close to the base units as possible When installing on concrete bases a higher central support is provided to support the L profiles Set ballast L profiles support Plate screws Ballast tile provided by customer In arrangements where the system is placed on So lar PP supports the central support should also be placed on PP supports ...

Страница 10: ... unit and fill the container with pebble stones The pebble stone bins have a standard size If it is not possible to put these next to each other due to the length of the panel these could be placed alternately on the ground profile of the base unit ATTENTION It s forbidden to place gravel containers onto each other 7 PLACEMENT BALLAST PEBBLE STONE BINS Pebble stone bin Pebble stones INSTALLATION ...

Страница 11: ...o the mounting bracket and clamp them by using the appropriate end and mid dle clamps The clamp instructions for the PV modules must always be respected Drawings are for illustration purpose only ATTENTION Tighten the Allen screws manually for the first three revolutions before tightening them with the electric screwdriver Clamps hexagonal socket screws Solar panel provided by customer INSTALLATIO...

Страница 12: ...ofile is placed over the ends of the pro files In the middle the ridge profile can be folded to the appropriate angle It is then fastened to the base units with 8 self tapping screws Longitudinal ridge connections With the longitudinal ridge connection the basic units are connected to each other by means of an L profile These are fixed with at least two self tapping screws to the top of both rails...

Страница 13: ...l frames where solar panels are installed should be grounded Because the rows are connected electrical and mechanical by L profiles and gravel containers step 6 installing the ballast no further connections have to be made between the different base units The separate fields have to be electrically conducted with each other via a ground wire This connec tion can be made by clamping the isolation f...

Страница 14: ...is attached to the rail by hooking the Z part of the support over the opening of the rail It is then fixed to the rail with a plate screw Cable tray supports Plate screw Cable tray not provided by Allimex Cable clips The SolarSpeed cable clips make it possible to hang cables under the panel The cable clips can be pressed into the provided holes in the SolarSpeed triangle and offer space for cables...

Страница 15: ...ng frames of Allimex are not suitable unless there is a written acknowledgement of Allimex concerning a specific project Roof height 20m Roof pitch PVC roofs 3 Roof pitch non PVC roofs 4 Places where nearby buildings of other objects cause a wind tunnel effect or increased wind speed Contamination of the roof skin can lead to a lower friction coefficient which means that more ballast has to be pro...