Product Description                                                                     

ALDES North America VentZone® IAQ systems are the only central ventilation systems available that provide precisely 

regulated whole-house Indoor Air Quality and centralized bathroom fans in a single, highly effective and efficient ventilation 

kit. Each kit has the capability to provide low, continous IAQ ventilation and zone-based on-demand “boost” ventilation. 

Optional ALDES North America fans are designed to meet ASHRAE 62.2, ENERGY STAR with IAP, LEED for Homes, and 

California Title 24 (CAL GREEN) standards.

VENTZONE

®

 SYSTEMS

RESIDENTIAL SYSTEM 

SOLUTIONS

VENTZONE

®

 

IAQ CONTINUOUS  

EXHAUST VENTILATION ACCESSORY KITS

Number of 

Bathrooms

6” ZRT-2 

(120 VAC)

CAR3®: 45-260 CFM

4” ZRT-2 

(120 VAC)

CAR3®:15-85 CFM

RECOMMENDED FAN

Sold separately

ENERGY STAR Certified* 

Ventilator

2

1

1

MPVS150

3

1

2

MPVS150

4

1

3

MPVS150

ZRT-2 PROVIDING 

LOW-CONTINUOUS EXHAUST 

IN UNOCCUPIED  BATHROOM

ZRT-2R PROVIDING 

ON-DEMAND BOOST 

EXHAUST IN OCCUPIED 

BATHROOM

ZRT-2R PROVIDING 

LOW-CONTINUOUS 

EXHAUST IN 

UNOCCUPIED 

LAUNDRY ROOM

MPVS

©2020 American ALDES Ventilation Corporation. VZ_IAQ_ContinuousExhaust_KIT_IOM_1020. Aldes reserves the right to modify its products at any time to introduce new technologies.

 

For more information, contact your Aldes sales advisor, visit aldes-na.com, call 1.800.255.7749, or find us on

IOM

Additional Accessories

29 010

Electronic Push-Button Timer (15/30/60/120 minutes for ZRT Operation)

29 011

Electronic Fan/Light Timer (15/30/60/120 minutes for separate ZRT/Light Operation)

Summary of Contents for MPVS150

Page 1: ... 6 ZRT 2 120 VAC CAR3 45 260 CFM 4 ZRT 2 120 VAC CAR3 15 85 CFM RECOMMENDED FAN Sold separately ENERGY STAR Certified Ventilator 2 1 1 MPVS150 3 1 2 MPVS150 4 1 3 MPVS150 ZRT 2 PROVIDING LOW CONTINUOUS EXHAUST IN UNOCCUPIED BATHROOM ZRT 2R PROVIDING ON DEMAND BOOST EXHAUST IN OCCUPIED BATHROOM ZRT 2R PROVIDING LOW CONTINUOUS EXHAUST IN UNOCCUPIED LAUNDRY ROOM MPVS 2020 American ALDES Ventilation C...

Page 2: ...ol damper the low flow regulator is removed from the air stream allowing unrestricted maximum boost ventilation Airflow rate can be set or adjusted by rotating the dial from either side The airflow indicator will move to show the selected CFM The airflow label has multiple defined setpoints but the unique adjustment mechanism of the CAR3 allows for infinite adjustability between the minimum and ma...

Page 3: ...h and comfort of the occupants as well as an investment in the protection of the building from the damaging effects of excessive indoor humidity 6 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 7 When cutting or drilling into wall or ceiling do not damage electrical wiring and hidden...

Page 4: ...control each ZRT and fan in this configuration Continuous fan operation using 120 VAC power supply to ZRT 2 terminals The fan and ZRT terminals may be wired independently Intermittent fan operation using 120 VAC power supply to ZRT 1 terminals SPST convenience switches such as push button timers or motion sensors may be used to control each ZRT and fan in this configuration FIGURE 2 FIGURE 3 FIGUR...

Page 5: ...ter and ZRT 1 terminals SPST convenience switches such as manually operated mechanical timers or dehumidistats may be used to control each ZRT and fan in this configuration The fan is controlled by the ZTC Int Cont Input Output to Fan A FIGURE 5 Continuous fan operation using 24 VAC ZTC Zone Terminal Control Center and ZRT 2 terminals SPST convenience switches such as manually operated mechanical ...

Page 6: ...geffect ontheairflow noiseandenergyuseofthefan Usetheshortest straightest duct routing possible for best performance and avoid installing the fan withsmallerductsthanrecommended Insulationaroundtheductscan reduceenergylossandinhibitmoldgrowth Fansinstalledwithexisting ducts may not achieve their rated airflow Use ductwork of a diameter that is the same as or greater than the diameter of the duct c...

Page 7: ...on s of field installed 4 side tap collar s shown as dashed lines This table should only be used as a general guide Actual duct length allowances may be longer on some models Contact the factory for assistance NOTE 3 Ducting may be substituted to permit installation in partition walls Smaller diameter ducting has increased resistance to airflow For each foot of 3 ducting substituted for 4 diameter...

Page 8: ...SS DOOR Additional 4 collar s may be provided for field installation depending on your specific model Collars are installed on the side s of the base MPVS at the knock out locations as indicated below 1 2 MOUNTING BRACKET LOCATIONS 1 Remove the metal knock out using a slot type screw driver or similar tool Make one firm hit to holding tabs The liner applied to the inside of the knock out should br...

Page 9: ...sing threaded rods or chains At least 12 inches clearance from the access panel is needed to permit servicing the motor Loose fill or batt insulation can be installed over the unit if the unit s access doors can still be opened VENTERGY SERIES FANS RECTANGULAR DUCT FAN RDF INSTALLATION SUPPLEMENT Mounting Differences in bracket type and configuration may exist on some derived models Refer to suppl...

Page 10: ...ng method and mode of operation continuous manually or automatically controlled Proper duct design for friction losses with compatible supply orexhaustgrilles airflowandacousticpropertiesofthesupply exhaust grilles and compatible wall roof caps Methodofbalancingairflowsofmulti pointventilationsystems Consideration for potential condensation in the ducting or fan housing installation in an unheated...

Page 11: ... CONTRACTOR INSTALLER TO DETERMINE THE SUITABILITY OF THIS EQUIPMENT WITH RESPECT TO THE POTENTIAL FOR BACKDRAFTING NATURALLY VENTED FLUE DEVICES AND OR AFFECTING RADON ENTRY Impact of Exhaust Fans In especially tight homes heated with naturally vented appliances such as gas oil or wood fired furnaces boilers stoves or fireplaces the exhaust system may produce sufficient negative pressure indoors ...

Page 12: ...o observe the following safety warnings Warning TO REDUCETHE RISK OF FIRE USE ONLY GALVANIZED STEEL DUCTWORKWHEN REQUIRED TO USE METAL DUCT NOTE If only rigid ducting is allowed a metal sound attenuator shall be installed between the fan and the range hood NOTE If the fan is not connected to a range hood or a grille in the vicinity of the cooking surface other approved ducting may be used as descr...

Page 13: ...SOLETE OR UNSALABLE PRODUCT S ALDES MAY AT ITS DISCRETION ACCEPT RETURN OF SALABLE PRODUCT S SUBJECT TO A 25 RESTOCKING CHARGE 1 No product s will be accepted without a Return Materials Authorization RMA number RMA number can be obtained by calling ALDES at 1 800 255 7749 Have the Bill of Sale or proof of date of installation available 2 RMA must be clearly marked on outside of carton or delivery ...

Page 14: ... the time delay has expired the device will automatically turn OFF and the POWER LED will change back to red To turn the device OFF before the time delay is finished press the ON OFF button To change the pre set delay time press the bottom TIME button to cycle through the four available time delays A green light LED indicates the stored selection ELECTRONIC FAN TIMER FAN CONTROLS P N 29 010 PUSH B...

Page 15: ...ires and switch into wall box and secure with the two mounting screws provided 6 Install decorator style wall plate not included 7 Turn power ON at circuit breaker or fuse panel 2020 American ALDES Ventilation Corporation 29 010 Electronic Push Button Timer_Spec_and_IOM_1020 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contact your ...

Page 16: ...he selected time delay factory default setting is 20 minutes When the time delay is completed the fan will automatically shut OFF Press the bottom TIME DELAY SELECTION SWITCH to cycle the fan time delay to 20 40 or 60 minutes The corresponding LED will light indicating the selected time period NOTE Both TIME DELAY LEDs indicate a 60 minute time period ELECTRONIC FAN LIGHT TIMER FAN CONTROLS P N 29...

Page 17: ...ch into wall box and secure with the two mounting screws provided 6 Install decorator style wall plate not included 7 Turn power ON at circuit breaker or fuse panel 2020 American ALDES Ventilation Corporation 29 011 Electronic Fan Light Timer_Spec_and_IOM_1020 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contact your Aldes sales adv...

Reviews: