background image

FOR ELECTRIC LOCK

AND SECURITY SYSTEM INSTALLATIONS

 

 

 

KP-100A

BACKLIT DIGITAL KEYPAD

Alarm Controls

10027 S. 51st Street, Ste. 102

Phoenix, AZ 85044

800.0645.5538

alarmcontrols.com

ASSA ABLOY, the global leader

in door opening solutions

Summary of Contents for KP-100A

Page 1: ...OCK AND SECURITY SYSTEM INSTALLATIONS KP 100A BACKLIT DIGITAL KEYPAD Alarm Controls 10027 S 51st Street Ste 102 Phoenix AZ 85044 800 0645 5538 alarmcontrols com ASSA ABLOY the global leader in door opening solutions ...

Page 2: ...d Master Code Supervisor Code Operation and Functions of The Supervisor Code User Codes How to Add or Delete Visitor Codes Output Modes Timing Personal Safety And System Lock Out User Code Entry Mode Auto or Manual Keystroke Echo Tones On Off Selection Relay Output Operation Announcer Status LED Flashing On Off during Standby Intelligent Egress Button An Unique Feature of A Contemporary Keypad Whe...

Page 3: ...trol and alarm system arm disarm control It is also a programmable industrial timer from 1 second to over 24 hours for automatic door operator system FEATURES Loaded with the 2nd generation KP 100A operation software Controls Entry with User Codes and Exit with programmable egress button feature Total 1 000 User Codes for door lock control and 50 visitor codes Indoor installation Stainless steel f...

Page 4: ...de Entry 10 seconds waiting for next digit entry The Timer 1 99 999 Seconds Over 24 Hours possible Programmable Timer Egress Button Programmable for Instant Delay with Warning Momentary or Holding Contact for the Exit Delay Output Contact Ratings Output Relay 1 Form C dry contacts 5A 30 VDC Max Tamper Switch N C dry contact 50mA 24VDC Max Dimensions Includes ABS Plastic box 117 H X 74 W X 48 D mm ...

Page 5: ...atient to study the manual to become familiar with the specifications of the system before starting the installations Do not apply power to the system while it is being installed Check carefully all the wiring is correct before applying power to the system for testing Prevent Accidental Short Circuit PRECAUTIONS INSTALLATION ASSEMBLY AMBER RED GREEN FIXING SCREWS X 2 KP 100A ...

Page 6: ...ally Open and Normally Closed contacts Use N O output for Fail secure locking device and N C output for Fail safe locking device The relay can be programmed in Start Stop toggle mode or time release mode See programming Function 51 Page 19 for the details 8 EG IN Egress Input A Normally Open N O input terminal referenced to ground With the help of connecting a normally open button to activate Outp...

Page 7: ...keystrokes Echo Tones can be ON or OFF through the programming option see Function 71 page 21 The Output Relay Activation Tone can be selected through the programming option at Function 72 page 22 The Standby flashing can be turned ON or OFF through the programming option at Function 73 page 22 LED INDICATORS KEYSTROKE ECHO TONES STATUS ECHO TONES AMBER LED 1 In Programming Mode ON 2 Successful Ke...

Page 8: ...reject repeated use of prime code in programming and give one long Echo Tone indication Example User 13579 24680 1234 3456 Output 1 Output 1 Output 1 Output 1 004 003 002 001 10 10 10 10 Tracy Tom May John Name Function User ID Code Remark 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 000 B LIST OF USER INFORMATION The keypad can accommodate up to 1 000 users To avoid confusion and for programming conv...

Page 9: ... go to Function 01 page 12 and program in your new Master Code c DO NOT turn off power while the keypad is in programming mode Otherwise it may cause an error to the data in memory 9 PROGRAMMING OPERATION POWER UP THE KEYPAD The keypad gives power up delay of 1 minute after power has been applied It is the time frame designed for setting the keypad to programming mode with DAP code See the details...

Page 10: ...se the Master Code is forgotten apply the following procedures precisely to set keypad into programming mode with DAP code 1 2 3 4 Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged Switch ON power again The keypad will be in Power up Mode for 1 minute The keypad will give a continuous Echo Tone and the Status LED will be flashing This is the only time frame to acc...

Page 11: ...O P 1 Nil User Program Required 4 0 Visitor Codes Nil User Program Required 5 1 O P Mode of The O P 1 Time 5 Sec Momentary Code 1 10 False Code Lock out 60 Sec Code 2 Manual Entry Mode Code 1 Flashing Enabled Code 1 0 Instant No Delay Code 2 1 Momentary Contact without Warning Code 1 Pacifier Tone ON Code 1 Sec Notification Beep ON 6 0 Wrong Code Keypad Lock out 7 0 User Code Entry Mode 7 1 7 2 O ...

Page 12: ... be 4 to 8 digits When a new Supervisor Code is keyed in and confirmed it will overwrite and replace the previous Supervisor code 3 VALIDATION Press key to confirm code entry 12 Example a Set a Supervisor Code 2 5 8 0 b Deleted a Supervisor Code from memory Key in the Location number and 4 to 8 Digits 02 1 2 3 FUNCTION SUPERVISOR CODE VALIDATION 02 4 to 8 Digits 01 Master Code is the authorization...

Page 13: ...pen at anytime for safety 2 Override The Door Lock Controlled by Output Relay Keep Door Un locked Toggle Mode The Output Relay is usually for door lock control In some situations the door may require un locked for a period of time to allow door opening without User Code for entry exit convenience This function Starts Stops the toggle mode with the following code entry The Door is Un locked or Togg...

Page 14: ...odes for it become invalid and those people holding a User Code are refused This function Starts Stops with the following code entry User Code Operation Inhibited Start Stop NOTE The door is locked during Output Relay inhibited and the INHIBIT LED Red is ON Lockout applies to all User Codes for Output relay SUPERVISOR CODE Attempting to input an User Code will cause the yellow LED to flash five ti...

Page 15: ...iew Function 70 page 21 at this 5 Delete User Codes from the selected User ID Delete an User Code by keying in its address number 0999 Group Clearing Clear all the User Codes of the selected User Group Location 3 USER ID The IDs of The User Codes 000 999 1 000 User addresses for the User Codes in User Group 1 Output Relay 4 USER CODE Key in User Code into each assigned User ID 5 VALIDATION Press t...

Page 16: ... Confirm it with the key Output 1 activates 2 Example 2 Delete An User Code a b c d a Key in the User Group that the User ID belongs to 10 for Group 1 b Key in 5 that is the Command Code for making a deletion c Key in the User ID that stored the User Code d Press the key Two Echo Tones confirms a valid entry and the User Code in that User ID is cleared User ID 3 Example 3 Clear The Whole Group of ...

Page 17: ...leared by the system Time Limit in Hour s 4 8 DIGITS 40 01 50 00 or 01 99 VISITOR CODE VALIDATION FUNCTION VISITOR ID VALID PERIOD 5 4 3 2 1 The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a two digit number of 01 to 99 The visitor code is cleared by the system when the time limit is reached 40 Clear all the Visitor Codes in Function 40 Please see the Programming e...

Page 18: ...ours a b c d e a Visitor Code Programming b The Visitor ID c Valid for 3 Hours d The Visitor Code e Example 3 Delete a Visitor Code from Vistor ID 02 in the memory a b c a Visitor Code Programming b The Visitor ID c Delete Confirmation Example 4 Clear all Visitor Codes in Location 40 a b c a Visitor Code Function b The Deletion Command Code c Confirmation all Visitor Codes are When finished press ...

Page 19: ...to the function of the Supervisor code but now ALL User Codes will toggle the output relay Seconds Momentary Default Momentary 5 Seconds The output can be set in Momentary Mode with the time of 1 second to 99 999 seconds The output will reset automatically when the time expires 3 VALIDATION Press key once Two Echo Tones confirms the entry When finished Press to exit Programming Mode RESET OUTPUT T...

Page 20: ...locks for 60 seconds 5 10 Selection of after 5 to 10 successive false User Code trials the keypad locks for Example Release the lock up 00 Remove all the above lock up securities 3 VALIDATION Press key once Two Echo Tones confirms the entry When finished press to exit Programming Mode 20 SUPERVISOR CODE 1 to 2 Digits LOCK UP OPTIONS VALIDATION FUNCTION 60 3 2 1 Default 15 minutes The keypad can be...

Page 21: ...y in code trial by the unauthorized people 3 VALIDATION Press key once Two Echo Tones confirms the entry When finished press to exit Programming Mode KEYSTROKE ECHO TONES ON OFF SELECTION Function 71 Enter Programming Mode by entering Program Code and 1 FUNCTION Key in Function 2 FUNCTION MODES FOR KEYSTROKE ECHO TONES Keystroke Echo Tone is the Echo Tones from the keypad which include the tones o...

Page 22: ...ngth of time that the relay is energized 2 Short Beeps Notification 2 short Echo Tones Echo Tones sound when the output relay activates Note The green LED will stay illuminated for the entire length of time that the relay is energized 3 VALIDATION Press key once Two Echo Tones confirms the entry When finished press to exit Programming Mode STATUS LED FLASHING ON OFF DURING STANDBY Function 73 Ente...

Page 23: ...the special function in normal use Just leave it on its default values WHERE AND WHY EXITING NEEDS ATTENTION Examples for some areas may need an Intelligent Egress Button Hospital Some of the patients are not allowed to leave the ward without staff permission An egress button with exit delay and warning Echo Tones will help the nurse or staff to get attention to the door when the egress button is ...

Page 24: ...cy Exit is not open to the public for daily use It is for emergency case only It is usually closed and watched by guards The egress button of this keypad can be programmed to offer exit delay with warning Echo Tones and even gives alarm output to trigger an alarm system when the door is forced to open or the door is open after the exit delay expired It is an useful tool to get attention of the per...

Page 25: ...eached NOTE Most juridictions will only permit either 15 or 30 seconds of delay 25 CONFIGURATIONS VALIDATION DELAY TIME FUNCTION 0 or 1 99 90 Press the Button once No warning or alarm is given during Egress Delay Good for silent area The people have to wait for the door open until the delay time is reached The default setting on 0 second delay Press the Button once The system gives Warning Tones d...

Page 26: ...3 Set Egress Button in Momentary contact without delay This is the default setting a b c d a Egress function programming b Momentary contact without delay c Release door instantly d Entry confirmation When finished press to exit PRogramming Mode pressed Output 1 activates automatically door is released when the delay time is reached Codes always give INSTANT action Holding Contact The user MUST ho...

Page 27: ...27 CLOSE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming VALIDATION System is back to normal operation mode ...

Page 28: ...ALID PERIOD 00 One Time 01 99 Hours CODE 3 VISITOR CODE 4 8 Digits 40 CODE1 CODE2 CODE3 NIL 6 0 Wrong Code Keypad Lockout LOCK UP CODE 1 10 Trial Lock Up 60 Sec 5 10 5 10 Trial Lock Up 15 Minutes 00 No Lock Up 60 LOCK UP CODE Code 1 10 Trials Lock Up 60 Seconds 7 0 Code Entry Mode ENTRY MODE 1 Auto Mode 2 Manual Mode 70 ENTRY MODE Mode 2 Manual Mode Keystroke Echo Tone ON OFF 7 1 FUNCTION MODE 0 N...

Page 29: ...E IT IS CHANGED IF A NEW MASTER CODE IS PROGRAMMED 0000 OR NEW MASTER CODE System in Programming Mode 9 9 9 9 REFRESH CODE Refresh the system and set all its function back to default values 9999 All programmed data are cleared and back to the default values except the Master Code 2 8 2 8 DAP CODE Direct access to programming mode Valid only in the power up delay period 2828 System in Programming M...

Page 30: ...ect the 1N4004 as close as possible to the strike in parallel with the Electric Strike power terminals to absorb the counter EMF to prevent it from damaging the keypad To avoid Electro Static Discharge from interfering with the operation of the keypad always ground the terminal of the keypad to earth ...

Page 31: ...Adjust Potentiometer Button LED Power In 12 24VDC Timed Relay Momentary Switch 12 24VDC Power Supply ALARM CONTROLS TS 2 2T Reverse Side View Wired for Double Break Release Magnetic Lock B L U E WHITE ALARM CONTROLS TS 18 Optional Remote Release 1 BASIC WIRING OF A MAGNETIC LOCK Make certain that the Magnetic Lock is set at the same voltage as the Power Supply To meet Life Safety Requirements the ...

Page 32: ...DOCD0030_1 ...