background image

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE!

PK-1971199

Congratulations on your purchase
of Z-Line Standard Boltless Rack
from 

AFS

! Z-Line's

interlocking keyhole design not
only makes installation fast and
easy but eliminates the need for
clips, gussets, sway braces or
other hardware commonly used in
conventional shelving. This allows
completely free access to your
stored materials from all sides of
the unit.

Z-Line Boltless Rack is available
in both standard- and heavy-duty
strengths, in a variety of heights,
widths and depths to fit virtually
any storage application. Adding an
extra shelf is quick and easy. And
starter and adder units allow for
joining shelving units together .

GENERAL SAFETY INFORMATION
Some parts may have sharp edges.
CARE must be taken when handling
the pieces to avoid injury. For safety,
wear a pair of work gloves when
assembling or performing any
maintenance on shelving.

ASSEMBLY INSTRUCTIONS & PARTS MANUAL #1971199

 

(888) 891-1970 x 8958         Fax:

 (

951

679-0455 

Z-Line Standard Boltless Rack

Installation Instructions

SHELF LOAD CAPACITIES

Unit

Load Capacity,

Load Capacity,

Width

No Deck Support

With Deck Support

48"

1750 lbs.

2250 lbs.

72"

1250 lbs.

1750 lbs.

96"

750 lbs.

1250 lbs.

American Filing Solutions  P.O. Box 891719,  Temecula, CA 92589  Toll Free:  (888) 891-1970 x 8958  Fax: (888) 891-9970  Email: [email protected]   www.FilingToday.com

Summary of Contents for Z-Line

Page 1: ...ing an extra shelf is quick and easy And starter and adder units allow for joining shelving units together GENERAL SAFETY INFORMATION Some parts may have sharp edges CARE must be taken when handling the pieces to avoid injury For safety wear a pair of work gloves when assembling or performing any maintenance on shelving ASSEMBLY INSTRUCTIONS PARTS MANUAL 1971199 888 891 1970 x 8958 Fax 951 679 045...

Page 2: ...identify the various parts as they are mentioned A Single unit with four Angle Posts EUR A single unit will use EUR posts for all four uprights as shown below in Figure A If you plan on installing an adder unit however you should build your starter unit with two ZTP posts on one end which will join with the adder as shown in Figure B Narrow area of keyhole slot is at bottom 3 With help from an ass...

Page 3: ...d above If you have purchased a single unit your shelving unit is now complete and ready to use For adder units see step 10 7 Attach the remaining shelf supports at the desired shelf levels making sure that all shelf supports are completely seated in the upright slots NOTE If you have purchased additional shelf levels the shelf supports for the extra levels may also be inserted at this time 10 If ...

Page 4: ... a n s n o s r e p t c a t n o C c t e y e r G m u i d e M e i r o l o C m o r f d e s a h c r u p s a w t c u d o r p e h t o h W d e g a m a d t i s a w r o g n i s s i m m e t i s a W If requesting parts by telephone ask for customer service and have as much of the above information ready as possible EUR Upright Ref No 1a Front to Back Shelf Support Ref No 2 Particleboard Decking Ref No 5 Left ...

Reviews: