background image

34942 G

Instruction Booklet

Gas Hob

GB

Содержание 34942 G

Страница 1: ...34942 G Instruction Booklet Gas Hob GB...

Страница 2: ...2...

Страница 3: ...prevents them from using the appliance safely without supervision or instruction by a responsible persontoensurethattheycanusetheappliancesafely Thehobgetshotwhenitisinuse Childrenshouldbekeptawayunt...

Страница 4: ...ofanoldappliance makeitunusable bycuttingoffthecable Thesymbol ontheproductoronitspackagingindicatesthatthisproductmay notbetreatedashouseholdwaste Insteaditshallbehandedovertotheapplicable collection...

Страница 5: ...er 16 Buildingoverakitchenunitwithdoor 17 Fittingthehobtotheworktop 18 Electricalconnections 19 PermanentConnection 20 Wiringdiagram 20 FaultFinding 21 Preliminary Electrical Systems Check 21 Ignition...

Страница 6: ...the event of a breakdown These instructions are only valid for countries whose identification symbols are shown on the inside cover of this instruction booklet and on the appliance itself 7 8 9 10 1...

Страница 7: ...he spark generator to be activated automatically In the absence of electricity ignition can occur without the electrical device in this case approach the burner with a flame push the relevant knob dow...

Страница 8: ...ports as shown in the diagram Assoonasaliquidstartsboiling turndowntheflamesothatitwillbarelykeeptheliquid simmering If you use a saucepan which is smaller than the recommended size the flame will spr...

Страница 9: ...pbecomeheavilysoiled thefollowingproductsarerecommended Forstainlesssteelhobsuseaproprietarystainlesssteelcleaner For other hobs use Hob Brite or Bar Keepers Friend Pan Supports Thepansupportsaredishw...

Страница 10: ...blown Check the burner cap and crown have been replaced correctly e g after cleaning Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown ha...

Страница 11: ...a 3 amp cartridge fuse HEAT INPUT Rear Left Burner 2 0 kW 6824 BTU HR semi rapid Front Left Burner 3 0 kW Natural Gas 10236 BTU HR rapid 2 8 kW L P G 9554 BTU HR Rear Right Burner 2 0 kW 6824 BTU HR...

Страница 12: ...W 3 0 0 75 2 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE m3 h 0 286 0 057 0 190 0 038 0 095 0 028 0 381 0 114 NOZZLE REFERENCE 119 Adjust 96 Adjust 70 Adjust 146 Adjust 1 100 mm NOMINAL THERMAL POWER kW...

Страница 13: ...alledinabedsitting roomwithavolumeoflessthan 20m3 If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required Ifitisinstalledinaroomofvolumebetween5m3 an...

Страница 14: ...Ensurethatthereisaminimumdistanceof55 mm between the rear cut out edge and the wall A minimum distance of 150 mm must be left betweenthesideedgesofthecutoutandany adjacentcabinetsorwalls The minimum d...

Страница 15: ...the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with eit...

Страница 16: ...or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface It is also recommended to carry out the electrical connection to the hob as...

Страница 17: ...tactwiththebottomofthehobwhich can be heated when it is operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if tech...

Страница 18: ...releftinthisseal in order to prevent spillage near the hob seepingintothecabinetbelow 1 Place the sealing gasket all around the edge of the cut out 2 Placethehobintothecutout and secure it by means of...

Страница 19: ...nge the fuse a 3ampASTAapproved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Ye...

Страница 20: ...3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations The switch must not break the yellow and green earth cable at any poin...

Страница 21: ...supply should now be satisfactory Carry out D Resistance to Earth check Inlet wiring faulty Rectify any fault Isolate appliance and carry out B Insulation check Rectify any fault including replacing f...

Страница 22: ...t leads from L to N in appliance terminal block If meter reads 0 then there is a short circuit b meter set on W Ohm x 100 scale Repeat test with leads from L to E If meter reads less than infinity the...

Страница 23: ...he electrode Check by pass simmer adjusted Light burner manually Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and...

Страница 24: ...ap see diagram The b type has the adjustment screw located down the centre of th egas tap control shaft The c type has the by pass screw located to the side of the gas tap itself To adjust use a thin...

Страница 25: ...tysupply 3 Remove all pan supports burner caps rings crowns and control knobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injecto...

Страница 26: ...rviced maintained repaired takenapartortamperedwith by any person not authorised by us Electrolux Service Force Centre must undertake all service work under this guarantee Anyapplianceordefectivepartr...

Страница 27: ...t of your appliance requiring service or if you wish to purchase spare parts please contactyourlocalServiceForceCentrebytelephoning 08705929929 YourtelephonecallwillbeautomaticallyroutedtotheServiceFo...

Страница 28: ...eappliance guaranteewillmovewithyousubjecttothefollowingqualificati ons Theapplianceguaranteestartsfromthedateyoufirstpurchasedtheappliance whichwillbeevidencedbyproductionofavalidpurchasedocumentissu...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...35690 3002 12 07 R 0 Subject to change without notice...

Отзывы: