User Manual 

 

1kVA ~ 3kVA 220VAC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                           

 

Summary of Contents for ST3010

Page 1: ...User Manual 1kVA 3kVA 220VAC...

Page 2: ...USB Card 13 DB9 Dry Contact Card 13 AS400 Card 14 SNMP HTTP Agent 14 3 Operation 15 3 1 LCD and LED Display 15 LCD 15 LED 17 3 2 Starting up Shutting down the UPS 18 3 3 Operating Modes 19 3 4 Configu...

Page 3: ...F 0o C to 40o C The UPS is designed for data processing equipment It is not intended for use with life support and other designated critical devices The maximum load must not exceed that shown on the...

Page 4: ...as it supplies reliable pure and stable power at an affordable price Feature Benefits 9 True on line double conversion 9 PWM technologies w IGBTs 9 Wide input voltage range 9 DC Start 9 Battery self...

Page 5: ...User Manual 1 3kVA Rev 9 Page 2 of Total 30 1 Presentation 1 2 System Configuration Tower 1kVA 160W x 220H x 400D mm 15 kgs 2kVA 200W x 352H x 450D mm 34 kgs 3kVA 200W x 352H x 450D mm 35 kgs...

Page 6: ...User Manual 1 3kVA Rev 9 Page 3 of Total 30 1 Presentation Rack Mount 1kVA 440W x 88H x 465D mm 15 5 kgs 2kVA 440W x 88H x 465D mm 35 kgs 3kVA 440W x 88H x 465D mm 36 kgs...

Page 7: ...ult LED red 5 Select up button 6 Select down button 7 Enter button 5 6 Off button 6 7 On button 5 7 Test Silence button LED 1 2 3 4 5 6 7 8 9 1 Line LED green 2 Load Battery Capacity LEDs 3 Battery LE...

Page 8: ...tal 30 1 Presentation 1 3 2 Rack Mount 1 2 3 4 5 6 7 1 2 line LCD Display 2 Normal LED green 3 Warning LED yellow 4 Fault LED red 5 Select up button 6 Select down button 7 Enter button 5 6 Off button...

Page 9: ...2 8 7 9 9 2 8 9 10 3 4 4 4 5 5 5 3 3 1kVA 2kVA 3kVA 1 Standard RS232 Port 2 Fan 3 External Battery Slot Option 4 Input Breaker 5 Inlet 6 Communication ports DB9 USB AS400 SNMP HTTP Option 7 Surge Prot...

Page 10: ...2 5 9 7 1 8 3 2 long run time kVA 4 3 6 2 5 9 7 1 8 11 10 1 External Battery Slot Option 2 Outlets IEC 10A Germen 3 Inlet 4 Input fuse 5 Fan 6 Communication Ports DB9 USB AS400 SNMP HTTP Option 7 LCD...

Page 11: ...User Manual 1 3kVA Rev 9 Page 8 of Total 30 1 Presentation External Battery Bank or Module For Tower Product ranges For Rack Mount product ranges...

Page 12: ...l batter 1 Box ST 3200R Rack Mount N A internal battery 1 Box ST 3200R Rack Mount 1 Battery Module 2 Boxes ST Series 1kVA 3kVA Tower Box 1 c d e f Shipping Box Includes 1 UPS 2 User Manual 3 Input Pow...

Page 13: ...ng Box Includes 1 UPS 2 User Manual 3 Input Power Cord German British Australian 4 Extension Power Cord IEC to PC for output receptacles IEC only 5 2pcs 19 rack ears screws Box 2 for 2 3kVA Rack Mount...

Page 14: ...DSL Remote control USB To external battery cabinet DB9 Output to the loads To the wall socket SNMP HTTP Rack Mount To the wall socket Optional Communication Slot Output to the load To external battery...

Page 15: ...h specific monitoring software installed Please contact a sales representative for further information of monitor software The pins of the connector are as following The RS 232 interface settings are...

Page 16: ...B9 Dry Contact Card USB Card AS400 Card and SNMP HTTP Card USB Card DB9 Dry Contact Card Pin Definition of DB9 for NOVELL Interface PIN of DB9 Function explanation I O 1 UPS Fault Output 3 GND Input 4...

Page 17: ...rom the NetAgent Mini CD on a Windows environment and configure the IP address All the other configurations could be accomplished in a Web browser NetAgent Mini also provides shutdown programs for dif...

Page 18: ...0V 50Hz Display 3 UPS Status AC FAIL BATT LOW NO Output Display 4 Real Input Output Voltage and Frequency Input Voltage 220 VAC Output Voltage 220VAC Input Frequency 50 Hz Output Frequency 50 Hz Selec...

Page 19: ...ty 100 Display 6 Output Power Output Power 100 Display 7 Inside Temperature Inside TEMP 33 91 Display 8 New Alarm NEW AC Fail 1 ALM Overload 3 Display 9 Old Alarm OLD AC Fail 5 ALM Overload 9 Display...

Page 20: ...LED green This indicates the inverter is working normally 6 10 Load Battery Capacity LEDs a No 6 to 7 LED is green color No 8 to 9 is yellow and No 10 used as warning LED for overload or battery low i...

Page 21: ...rmal Mode the UPS is ready for operation Shutting down the UPS Press the Select up Select down button simultaneously for one second The UPS will turn off DC Start up of the UPS Step 1 Without connecti...

Page 22: ...The AC output power comes from AC utility input and passes through AC DC rectifier DC AC inverter and static switch to support power to load The battery charging voltage comes from AC utility input an...

Page 23: ...User Manual 1 3kVA Rev 9 Page 20 of Total 30 3 Operation Bypass Mode Under the following conditions the bypass will be enabled 1 Overload 2 Inverter failure 3 Over temperature...

Page 24: ...d Display 11 Output Voltage Frequency Setting Volt Freq Set 220 VAC 50 Hz Display 11 Output Voltage Frequency Setting Volt Freq Set 220 VAC 50 Hz Step 3 Use Select Up or Select Down keys to adjust the...

Page 25: ...I voltage settings Display 10 Bypass Voltage Setting Bypass Volt Set LO 176V HI 253V Step 2 The cursor will pop up to indicate the item newly selected Press the Enter key to select the item either HI...

Page 26: ...an ambient temperature range of 32 F to 104 F 0 C to 40 C Keep the UPS on a flat stable surface with a 10cm space around it for proper ventilation Do not place the unit near a heat source also avoid p...

Page 27: ...Use tools with insulated handles Do not lay tools or metal parts on top of batteries Do not attempt to alter any battery wiring or connectors Attempting to alter wiring can cause injury Do not dispose...

Page 28: ...t 1 Please contact with sale representative 2 Remove short circuit condition restart the UPS Fault Warning Normal y UPS stop working y The alarm beeps continuously AC OK BATT OK DC_BUS Fail 1 Power Bo...

Page 29: ...every 4 seconds AC Fail BATT OK Battery Mode 1 AC utility power fail 2 Input cable broken or disconnect with UPS 1 If AC utility power fails reduce the load in order to extend backup time 2 If it is...

Page 30: ...e UPS y Inverter LED illuminated y Alarm sounds every 4 second 1 AC utility power fail 1 UPS go to battery mode automatically 2 As the audible alarms per every 1 second battery is almost empty y Fault...

Page 31: ...50 load Battery Typical Backup Time Full load 5 minutes 9 minutes 5 minutes Battery Type Sealed Lead Acid maintenance free 12VDC 7AH per cell Numbers of Batteries 3 cells 8 cells Recharge Time to 90 5...

Page 32: ...45 34 26 3 EB 24pcs 1110 488 299 210 159 96 66 49 39 Rack Mount RUN TIME CHART in Minutes Output load UPS Model 200 VA 140 W 400 VA 280 W 600 VA 420W 800 VA 560W 1000 VA 700 W 1500 VA 1050 W 2000 VA...