background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SU2200RMNAFTA

SmartOnline Expandable 2U Rack / Tower UPS System - NAFTA assembled version of SU2200RTXL2Ua

 

Highlights

2200VA / 2.2kVA on-line, double-conversion, extended-run 2U rack / tower

UPS

Maintains sine-wave 100/110/120V +/-2% output during overvoltages to 138

and brownouts as low as 65V (50/60Hz auto-sensing)

Simultaneous communications via HID compliant USB port, serial port,

SNMP/Web card slot and EPO interface

Fault tolerant auto-bypass mode, current monitoring and switched PDU control

via 2 switchable output load banks

Input: NEMA 5-20P (120V) / Output: 6 NEMA 5-15/20R and 1 NEMA L5-20R

(120V)

$250,000 

Ultimate Lifetime Insurance

 (USA and Canada Only)

Description

2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an

installed depth of only 19 in. Expandable battery runtime with optional BP48V60-3UNAFTA external battery packs. Full-time sine wave 100, 110 or

120V +/-2% output. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then

re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and

overvoltages to 138V. NEMA 5-20P input plug; NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge and noise

suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB

port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto

shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power

conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface.

Integrated 2-bank PDU switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and

battery charge status LEDs. LED display panel easily rotates for better viewing in rackmount or tower configurations. Dataline surge suppression for

dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode.

4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack & wallmount accessories available.

Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. $250,000 

connected equipment

insurance

;

Package Includes

SU2200RMNAFTA On-line Double-Conversion UPS System 

PowerAlert Software and cabling

Mounting hardware for 4 post rack enclosures

Instruction manual with warranty information

Features

SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications

True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all

usage conditions

Summary of Contents for SmartOnline SU2200RMNAFTA

Page 1: ...between AC and battery operation Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration wit...

Page 2: ...d PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP UPS interface supports on batter...

Page 3: ...PDU redundancy options ATS switch options PDUMH20AT PDUMH20ATNET support dual UPS and hot swappable UPS configurations Output AC waveform AC mode Sine wave Output AC waveform battery mode Pure Sine wa...

Page 4: ...tion 4 LED meter displays load and battery charge levels LED panel rotates for viewing in rack tower formats Alarms Audible alarm indicates UPS startup power failure low battery overload UPS fault and...

Page 5: ...UPS Shipping dimensions height x width x depth inches 9 8 x 20 2 x 24 UPS Shipping dimensions height x width x depth cm 24 8 x 51 4 x 61 Shipping weight lbs 57 3 Shipping weight kg 26 UPS housing mat...

Page 6: ...ilure Cold start operation supported High availability UPS features Automatic inverter bypass Hot swappable batteries Green high efficiency features High efficiency economy mode operation Individually...

Page 7: ...tectors DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines 1 Surge Protectors DNET1 Network Surge Suppressor Essential protection for data and communication lines 1 Surge Pro...

Reviews: