background image

NetVanta 3200/3300/3400 Series Routers

Hardware Installation Guide 

1203860G1

NetVanta 3200

1203870G1

NetVanta 3205 (AC Version) 

1203980G1

NetVanta 3205 (DC Version)

1202880E1

NetVanta 3305

1202820G1/F1

NetVanta 3430

1200821E1/F1

NetVanta 3448

1200823G1

NetVanta 3450

1200824G1

NetVanta 3458

1200861L1

NetVanta 56K/64K Network Interface Module

1202862L1

NetVanta T1/FT1 Network Interface Module

1200862L2#NEBS

NetVanta T1/FT1 NEBS Network Interface Module

1202863L1

NetVanta T1/FT1 + DSX-1 Network Interface Module

1200872L1/1202872L1

NetVanta Dual T1 Network Interface Module

1200868E1

NetVanta E1/FE1 Network Interface Module

1200878E1

NetVanta E1/FE1 + G.703 Network Interface Module 

1200866E1

NetVanta Serial Network Interface Module

1200936E1

NetVanta SHDSL Network Interface Module, Annex A

1200937E1

NetVanta SHDSL Network Interface Module, Annex B

1202869E1

NetVanta ADSL Network Interface Module, Annex A

1202889E1

NetVanta ADSL Network Interface Module, Annex B

1702803F1

USB WWAN Network Interface Module (NetVanta 3305/3430/3448/3450/3458)

1200864L1

NetVanta Analog Modem Dial Backup Interface Module

1200865L1

NetVanta ISDN BRI Dial Backup Interface Module

1200875L1

NetVanta ISDN S/T Dial Backup Interface Module

4202825F1

Octal PoE Upgrade Bundle (NetVanta 3448/3458)

1950860G2

Enhanced Feature Pack Software for IPsec VPN Upgrade (NetVanta 3200/3205/3305)

4200368E1

Enhanced Feature Pack (Hardware and Software) for IPsec VPN Upgrade (NetVanta 3305)

1200827E1

NetVanta 3430/3448 Rackmount Kit

61200860L1-34AE
August 2019

Summary of Contents for 1200864L1

Page 1: ...ork Interface Module 1200866E1 NetVanta Serial Network Interface Module 1200936E1 NetVanta SHDSL Network Interface Module Annex A 1200937E1 NetVanta SHDSL Network Interface Module Annex B 1202869E1 Ne...

Page 2: ...blication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchased ADTRAN...

Page 3: ...yright 2019 ADTRAN Inc 3 Conventions Warnings provide information that could prevent injury or endangerment to human life Cautions signify information that could prevent service interruption or damage...

Page 4: ...r unplug the product from the electrical outlet and replace the part or contact your qualified service personnel Additional safety guidelines such as Waste Electrical and Electronic Equipment WEEE are...

Page 5: ...unit contains no user serviceable parts 6 This equipment is designed to connect to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and req...

Page 6: ...onsister en une combinaison quelconque de dispositifs la seule condition que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas cinq Canadian Emissions Requirements Th...

Page 7: ...in the complete corresponding source code of such software components from ADTRAN for a period of three years after our last shipment of this product by sending a money order or check for 5 to ADTRAN...

Page 8: ...8 26 NetVanta 3448 Features and Specifications 26 NetVanta 3448 Shipping Contents 27 NetVanta 3448 Front Panel Design 28 NetVanta 3448 Rear Panel Design 29 NetVanta 3450 29 NetVanta 3450 Features and...

Page 9: ...05 NetVanta 3430 NetVanta 3448 NetVanta 3450 and NetVanta 3458 59 Wall Mounting NetVanta 3200 3300 3400 Series 60 Supplying Power to the Unit 64 Powering the NetVanta 3200 65 Powering the NetVanta 320...

Page 10: ...19 NetVanta T1 FT1 DSX 1 NIM 45 Figure 20 NetVanta Dual T1 NIM 46 Figure 21 NetVanta E1 FE1 NIM 47 Figure 22 NetVanta E1 FE1 G 703 NIM 48 Figure 23 NetVanta Serial NIM 49 Figure 24 NetVanta SHDSL NIM...

Page 11: ...ta 3205 DC Version Only 80 Table A 5 ADSL Connector Pinouts 80 Table A 6 WAN DDS Connector Pinouts 81 Table A 7 WAN T1 Connector Pinouts 81 Table A 8 WAN E1 Connector Pinouts 81 Table A 9 DSX 1 Connec...

Page 12: ...page 58 For additional information on mounting options suppling power upgrading memory and installing a CompactFlash card refer to the following sections Mounting Options on page 59 Supplying Power t...

Page 13: ...ith ISsec VPN equipped devices IP encapsulation over Frame Relay RFC 1490 ADTRAN Operating System AOS command line interface CLI User friendly web based graphical user interface GUI Standards based eB...

Page 14: ...l Backup and Network Interface Modules on page 69 for more details NetVanta 3200 Shipping Contents Each NetVanta 3200 unit is shipped in its own cardboard shipping carton Open each carton carefully an...

Page 15: ...t The SLOT 1 NET DBU option slot supports various plug in NIMs These option modules are described in the section Option Modules on page 38 10 100Base T Ethernet Interface and Activity LEDs The Etherne...

Page 16: ...tegrated 10 100Base T Ethernet port RJ 45 Modular IP access routers for MPLS Frame Relay multilink Frame Relay PPP MLPPP PPPoE ATM and HDLC networks Integrated IP router with bridging Optional ISsec V...

Page 17: ...03 Serial V 35 X 21 EIA 530 SHDSL Annex A and Annex B ADSL Annex A and Annex B If needed an analog modem ISDN BRI U or ISDN BRI S T DIM can plug onto the NIM providing dial backup capability Refer to...

Page 18: ...anel LED descriptions are given in Table 1 on page 37 Figure 3 NetVanta 3205 Front Panel Layout NetVanta 3205 Rear Panel Design The NetVanta 3205 AC and DC version rear panels are shown below with a m...

Page 19: ...s NetVanta 3305 The NetVanta 3305 is a modular access router designed for cost effective branch office connectivity over MPLS Frame Relay multilink Frame Relay PPP MLPPP or Ethernet networks For VPN a...

Page 20: ...etwork management Integrated EIA 232 DCE configuration port DB 9 Optional dial backup ISDN BRI DIM ISDN S T DIM or analog modem DIM Front panel LEDs Size 17 25 inch W x 1 26 inch H x 7 75 inch D AC Po...

Page 21: ...owing items NetVanta 3305 base unit with attached mounting ears screws Quick start guide Detachable AC power cord Option module shipping contents are given in Option Module Shipping Contents on page 3...

Page 22: ...rnational routers are shipped with a universal input lump in line supply with the appropriate cables All of the 1U high products have universal power supplies and are shipped with the appropriate cabl...

Page 23: ...d logging mechanisms Network address translation NAT NAPT and NAT Traversal version 2 NAT compatible SIP ALG DHCP client server and relay XAUTH including RADIUS and RSA SecurID AAA support using local...

Page 24: ...ping damage If the equipment has been damaged in transit immediately file a claim with the carrier and contact ADTRAN Customer Service refer to the Support page on the ADTRAN website at http www adtra...

Page 25: ...low with a module installed Appendix A on page 79 provides pinouts WAN T1 DBU CONSOLE SLOT 1 NET DBU Figure 9 NetVanta 3430 1202820G1 Rear Panel Layout NetVanta 3430 Rear Panel Interfaces SLOT 1 NET D...

Page 26: ...al Ethernet modular IP router Modular Network Interface 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703 ADSL Annex A or Annex B SHDSL Annex A or Annex B serial or USB WWAN High performance...

Page 27: ...supports a variety of interchangeable NIMs and DIMs The NIMs available for the NetVanta 3448 provide a variety of WAN connectivity options including the following 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual...

Page 28: ...P N 1200814E1 Shipments of the NetVanta 3448 international units include the following items NetVanta 3448 base unit Quick start guide 4 rubber mounting feet All necessary power cords PoE external po...

Page 29: ...option Note that the NetVanta 3448 itself cannot be powered by this port 8 Switch Port Interfaces Ports 1 through 8 are RJ 45 connectors used to access the fully managed 10 100Base T Ethernet switch...

Page 30: ...tateful inspection firewall protects against denial of service DoS attempts Flash memory supports multiple images of AOS Interchangeable network interface modules NIMs Dial backup to any PPP compliant...

Page 31: ...g a USB cellular modem from the USB WWAN NIM NetVanta 3450 Shipping Contents Each NetVanta 3450 unit is shipped in its own cardboard shipping carton Open each carton carefully and avoid deep penetrati...

Page 32: ...industry standard 1 GB CompactFlash card Refer to Installing a CompactFlash Card on page 76 NetVanta 3450 Rear Panel Design The NetVanta 3450 rear panel is shown below with a module installed Appendi...

Page 33: ...ions Dual slot dual Ethernet modular IP router Modular Network Interface 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703 or ADSL Annex A or Annex B SHDSL Annex A or Annex B serial or USB W...

Page 34: ...etVanta 3458 supports a variety of interchangeable NIMs and DIMs The NIMs available for the NetVanta 3458 provide a variety of WAN connectivity options including the following 56K 64K DDS T1 FT1 T1 FT...

Page 35: ...panel is shown below Front panel LED descriptions are given in Table 1 on page 37 PoE Status WAN 2 DBU 2 ETH1 ETH2 SWITCH CompactFlash NetVanta 3458 WAN 1 DBU 1 CONSOLE 1 5 2 6 3 7 4 8 Figure 14 NetV...

Page 36: ...ta 3458 has a 48 VDC port on the rear panel to provide the voltage required for PoE applications This port is active only if the NetVanta 3458 has been ordered with the PoE option Note that the NetVan...

Page 37: ...all units Off There is no activity on the WAN or DBU port Green flashing There is activity on the WAN or DBU port LAN TD RD not present on all units Off There is no activity on the Ethernet port Gree...

Page 38: ...n page 49 NetVanta SHDSL NIM Annex A P N 1200936E1 on page 50 NetVanta SHDSL NIM Annex B P N 1200937E1 on page 51 NetVanta ADSL NIM Annex A P N 1202869E1 on page 52 NetVanta ADSL NIM Annex B P N 12028...

Page 39: ...15 foot RJ 45 to RJ 45 cable ADTRAN P N 3125M008 A NetVanta T1 FT1 DSX 1 NIM 1202863L1 Shipments of the T1 FT1 DSX 1 NIM include the following items T1 FT1 DSX 1 Network Interface Module Quick start g...

Page 40: ...1202869E1 Shipments of the ADSL NIM Annex A include the following items ADSL Network Interface Module Quick start guide 7 foot RJ 11 to RJ 11 cable ADTRAN P N 3127014 NetVanta ADSL NIM Annex B 120288...

Page 41: ...a base unit a network interface module and other appropriate contents based on the system level solution ordered Shipments of the ISDN S T DIM include the following items ISDN S T Dial Backup Interfac...

Page 42: ...ptional DIM is required for dial backup applications Figure 16 NetVanta 56K 64K NIM Features and Specifications Operating Modes Dedicated DDS leased line DDS Interface Supported Standards AT T TR 6231...

Page 43: ...3 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB...

Page 44: ...65016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out...

Page 45: ...DS0 channelized multiples of 56 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C DSX 1 Interface Line Interface D...

Page 46: ...Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C Clock Source Network Internal...

Page 47: ...AN E1 Interface Supported Standards ITU G 703 ITU T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized time...

Page 48: ...T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiples of 64 kbps Receiver Sensitivity...

Page 49: ...s An optional DIM is required for dial backup applications SERIAL DBU Cable length for the Serial NIM should not exceed 25 feet Figure 23 NetVanta Serial NIM Features and Specifications Operating Mode...

Page 50: ...ng of 2 pairs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock S...

Page 51: ...2 pairs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock Source...

Page 52: ...Interface ADSL over POTS Annex A Supported Standards ITU G 992 1 G dmt ITU G 992 2 G lite ITU G 992 3 ADSL2 G dmt bis ITU G 992 5 ADSL2 ANSI T1 413 Issue 2 Reach Extended ADSL READSL2 Connector RJ 1C...

Page 53: ...Features and Specifications ADSL Interface ADSL over ISDN Annex B Supported Standards ITU G 992 1 G dmt Connector RJ 11C 6 pin jack inner pair ATM Multiple Protocol over AAL5 RFC 2684 PPP over ATM RF...

Page 54: ...Guide shipped with the NIM or online at https supportforums adtran com See Table A 13 on page 83 for the USB WWAN connector pinouts WWAN Figure 28 NetVanta USB WWAN NIM Features and Specifications USB...

Page 55: ...s refer to Installing Dial Backup and Network Interface Modules on page 69 Features and Specifications Features ITU V 90 compliant Async Standards FCC Part 15 Class A EN 55022 Class A EN 55024 UL CUL...

Page 56: ...kup and Network Interface Modules on page 69 Features and Specifications Features Clear Channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D cha...

Page 57: ...ules on page 69 Features and Specifications Features Clear channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D channel switch compatibility wit...

Page 58: ...e personnel only and should be installed in a restricted access location as described in UL IEC 60950 1 To prevent electrical shock do not install equipment in a wet location or during a lightning sto...

Page 59: ...ting NetVanta 3205 NetVanta 3305 NetVanta 3430 NetVanta 3448 NetVanta 3450 and NetVanta 3458 The NetVanta 3205 NetVanta 3305 NetVanta 3430 NetVanta 3448 NetVanta 3450 and NetVanta 3458 are 1U high rac...

Page 60: ...Series units can be wall mounted By following these instructions exactly the NetVanta can be safely mounted to the wall Instructions for Rack Mounting the NetVanta 3205 NetVanta 3305 NetVanta 3430 Ne...

Page 61: ...Figure 29 Screws should be spaced horizontally approximately 5 inches apart Find exact positioning by using the location of the two keyed insets on the bottom of the unit as a guide Screws should be...

Page 62: ...h thick to a wall stud using 6 to 10 2 5 inch or greater in length wood screws Important Mounting to a stud ensures stability Using sheetrock anchors may not provide sufficient long term stability Hav...

Page 63: ...se guidelines and referring to Figure 31 Screws should be spaced horizontally approximately 2 3 4 inches apart Find exact positioning by using the location of the two keyed insets on the bottom of the...

Page 64: ...e an assistant hold the unit in position as you install two 6 to 10 1 inch or greater in length wood screws through the unit s brackets and into the mounted board See Figure 32 Proceed to the steps gi...

Page 65: ...connector into the receptacle labeled POWER on the back of the unit keeping the sheath retracted until the connector is fully inserted into the receptacle Release the sheath so that it covers the met...

Page 66: ...ed with the shipment The NetVanta PoE Power Supply should be installed in a restricted access location as described in UL 60950 1 Under full load the NetVanta PoE Power Supply may be hot to the touch...

Page 67: ...tallically connected to interfaces that connect to the outside plant or its wiring This interface is designed for use as an intra building interface only The addition of primary protectors is not suff...

Page 68: ...8V 1A AC In 48 VDC Power Supply AC In 24 48V 1A 24 VDC Power Supply To Earth Ground OR OR To comply with GR 1089 CORE Issue 3 this equipment must be installed ONLY in a DC C common bonding and groundi...

Page 69: ...3205 DC power connector Connect the ground terminal of the NetVanta 3205 DC power connector to Earth ground NetVanta 3200 3300 3400 Series Unit Installation 61200860L1 34AE Copyright 2019 ADTRAN Inc 6...

Page 70: ...either circuit board bends or flexes ensure that the connectors are firmly seated Secure the DIM to the NIM using the screws and standoff posts supplied See Figure 35 Slide the NIM with the DIM attach...

Page 71: ...against the chassis Secure the pins at both edges of the module Connect the cables to the associated device s Restore power to the unit DBU WAN T1 DSX 1 NetVanta 3200 3300 3400 Series Unit Installati...

Page 72: ...s of the module Restore power to the base unit Refer to the quick start guide that shipped with the NetVanta USB WWAN NIM for instructions on obtaining a cellular account and activating your USB cellu...

Page 73: ...unit Remove the nine screws and if necessary two mounting brackets see Figure 37 Using a 3 16 inch hex driver remove the two jack screws located on either side of the DB 9 port Carefully lift and rem...

Page 74: ...module can be installed one way only To avoid damage do not use excessive force To seat the module into the socket apply firm even pressure to each end of the module see the arrows in Figure 39 on pa...

Page 75: ...00 Series Unit Installation 61200860L1 34AE Copyright 2019 ADTRAN Inc 75 Figure 38 SODIMM Installation Keyed Slots Figure 39 SODIMM Installation Applying Pressure Figure 40 SODIMM Installation Rotatin...

Page 76: ...when installing a card Slide the module into the CompactFlash slot until the card is firmly seated against the chassis The CompactFlash options will now be available in the GUI and the AOS CLI C o m p...

Page 77: ...ffs supplied with the NetVanta Octal PoE module into the two holes from which you removed the PC board mounting screws Carefully align the 34 pin receptacle on the Octal PoE module with the 34 pin hea...

Page 78: ...Installation Your NetVanta unit is now ready to be configured and connected to the network For information on configuration for a specific application refer to the configuration guides provided on th...

Page 79: ...5 SG Signal Ground 6 DSR Data Set Ready output Tied to pin 1 7 Unused 8 CTS Clear to Send output Tied to pin 1 9 Unused Base Unit Pinouts Table A 1 10 100Base T Ethernet Port Pinouts Pin Name Descrip...

Page 80: ...dicate output 24 VDC Source 48 VDC Source 1 24 VDC Ground GND 2 Ground GND 48 VDC Description 1 2 Unused 3 T ADSL Tip 4 RT ADSL Ring 5 6 Unused Connection directly to an external modem requires a cros...

Page 81: ...the network Ring 5 T Transmit data toward the network Tip 6 8 Unused Description 1 R1 Receive data from the network Ring 1 2 T1 Receive data from the network Tip 1 3 Unused 4 R Transmit data toward t...

Page 82: ...Transmit data toward the DTE Tip 3 Unused 4 R1 Receive data from the DTE Ring 1 5 T1 Receive data from the DTE Tip 1 6 8 Unused Description 1 T2 Loop 2 Tip 2 R2 Loop 2 Ring 3 Unused 4 T1 Loop 1 Tip 5...

Page 83: ...d Description 1 Vbus Provides 5 VDC power up to 1000 mA 2 D Data 3 D Data 4 Ground Ground NetVanta 3200 3300 3400 Series 61200860L1 34AE Copyright 2019 ADTRAN Inc 83 Table A 12 WAN ADSL Connector Pino...

Page 84: ...13 CTS_B V 11 only 11 D 5 5 CTS_A 12 E N A 6 DSR_A 13 K N A 25 TM_A 14 S 9 14 TD_B 15 W N A 11 ETC_B 16 AA N A 12 TCLK_B 17 X 13 9 RCLK_B 18 T 11 16 RD_B 19 25 N A N A N A Unused 26 B 8 7 Ground NetVa...

Page 85: ...p 6 T1 Network Transmit Tip 1 7 8 Unused An optional DIM is required for dial backup applications NetVanta 3200 3300 3400 Series 61200860L1 34AE Copyright 2019 ADTRAN Inc 85 Dial Backup Interface Modu...