User Manual   

CAN / Modbus TCP Slave

 

 

Document code: MN67515_ENG     Revision 2.100    Page 1 of 30

 

 

  

User Manual

Revision 2.100
English

CAN/ Modbus TCP Slave - Converter

(Order Code: HD67515-A1, HD67515-B2)

Benefits and Main Features:

 

Very easy to configure

 

Low cost

 

32mm Rail DIN mount

 

Wide supply input range

 

Temperature range: -40°C/+85°C (-40°F/+185°F)

HD67515-A1 

HD67515-B2 

Summary of Contents for HD67515-A1

Page 1: ...515_ENG Revision 2 100 Page 1 of 30 User Manual Revision 2 100 English CAN Modbus TCP Slave Converter Order Code HD67515 A1 HD67515 B2 Benefits and Main Features Very easy to configure Low cost 32mm R...

Page 2: ...customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document not...

Page 3: ...LIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commi...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual CAN Modbus TCP Slave Document code MN67515_ENG Revision 2 100 Page 4 of 30 EXAMPLES OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual CAN Modbus TCP Slave Document code MN67515_ENG Revision 2 100 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67515 A1...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual CAN Modbus TCP Slave Document code MN67515_ENG Revision 2 100 Page 6 of 30 Figure 1b Connection scheme for HD67515 B2...

Page 7: ...tion between two Buses to read CAN frame from Modbus word to write CAN frame from Modbus word Mountable on Rail DIN Temperature range from 40 C to 85 C This device is able to manage a maximum of four...

Page 8: ...ion 2 100 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Devi...

Page 9: ...ith Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the oper...

Page 10: ...e received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link green ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ether...

Page 11: ...sing Connector5 of HD67515 A1 HD67515 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in...

Page 12: ...For terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch A is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm...

Page 13: ...runs with Windows called SW67515 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable CAN Modbus TCP Slave Converter in order to configure another device in the same manner...

Page 15: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Page 16: ...he CAN with a CobID of 11Bit is used otherwise if the field CAN Bus 2 0B is checked the CAN with a CobID of 29Bit is used only if Device till April 2014 with Jumper is set TimeOut is the timeout of th...

Page 17: ...verter will receive from CAN network If Device till April 2014 with Jumper is set in the section Set Communication the window appears like below In the field Cob ID insert the Cob ID of the CAN frame...

Page 18: ...insert the Cob ID of the CAN frame In the field Type insert the type of the CAN protocol used for each frame CAN 2 0A 11 bits or CAN 2 0B 29 bits In the field Dimension insert the number of bytes of...

Page 19: ...hat you inserted in Receive COB Section In the field List of Modbus Registers there are the Modbus words In the field Create Modify a Modbus Register you can define the index of the Modbus register an...

Page 20: ...n this section it is possible to define the CAN frames that the converter will send to the CAN network If Device till April 2014 with Jumper is set in the section Set Communication the window appears...

Page 21: ...N protocol used for each frame CAN 2 0A 11 bits or CAN 2 0B 29 bits In the field Dimension insert the number of bytes of the CAN frame the maximum dimension is 8 Bytes If the field RTR is checked the...

Page 22: ...field Create Modify a Modbus Register you can define the index of the Modbus register and the bytes of the CAN frame where you write it With the field Send CAN frame on Modbus Write it is possible to...

Page 23: ...se instructions Turn off the Device Connect the RS232 Null Modem cable form your PC to the Converter Put Dip2 of Dip Switch A in ON position Select the COM port and press the Connect button Turn on th...

Page 24: ...the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A in ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 20...

Page 25: ...the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this...

Page 26: ...ettings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista and 8 make sure that you have the administrator privileges In...

Page 27: ...Fweb com S r l User Manual CAN Modbus TCP Slave Document code MN67515_ENG Revision 2 100 Page 27 of 30 MECHANICAL DIMENSIONS Figure 10 Mechanical dimensions scheme for HD67515 A1 Figure 11 Mechanical...

Page 28: ...l mounting B 4M 35mm DIN Rail mounting Device Family HD67515 CAN Modbus TCP Slave Converter Order Code HD67515 A1 CAN Modbus TCP Slave Converter Housing type A Terminal Blocks Connectors Order Code HD...

Page 29: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Page 30: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to t...

Reviews: