Страница 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P 631 543 8900 F www accu scope com info accu scope com 3075 GS Zoom Stereo Microscope on Gem Stand MANUAL ...

Страница 2: ...631 864 1000 www accu scope com 1 CONTENTS SAFETY NOTES 2 REPAIR CARE AND MAINTENANCE 2 INTRODUCTION 3 UNPACKING AND COMPONENTS 3 COMPONENTS DIAGRAM 3 ASSEMBLY 4 6 ADJUSTMENT AND OPERATION 7 9 REPLACING THE ILLUMINATOR LAMPS 10 11 TROUBLESHOOTING 12 MAINTENANCE 13 SERVICE 13 WARRANTY 13 ...

Страница 3: ...pe NOTE Always plug the Microscope power cord into a suitable grounded electrical outlet A grounded 3 wire cord is provided CARE AND MAINTENANCE 1 Do not attempt to disassemble any component including eyepieces objectives or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt ...

Страница 4: ...cedures ensure each microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if needed Avoid placing the microscope in dusty surroundings or in high temperature or humid areas as mold and mildew can form Carefully remov...

Страница 5: ...DIAGRAM The diagram below shows how to assemble the various components The numbers indicate the order of assembly When assembling the Microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Stereo Head Lock Screw Power Cord Eyepieces Fluorescent Illuminator Gem Clamp ...

Страница 6: ...rew on the stand and insert the stereo head into the bracket of the stand Tighten the lock screw to secure the stereo head Installing the Eyepieces Fig 1 Remove the eyepiece dust caps and insert the eyepieces until they stop as shown in Fig 1 Installing the Stoneholder Fig 2 The stage has two stoneholder mounts on either side of the stage where you can attach the stoneholder Fig 1 Fig 2 ...

Страница 7: ...d connector into place Hand tighten the connector If possible it is recommended to further tighten the connector by using rubber tipped pliers This will ensure that the gooseneck will not loosen and rotate as the overhead fluorescent light is being used Installing the Optional LED Light Fig 3A Remove the plastic cap covering the opening to the LED socket Insert the LED light guide into the socket ...

Страница 8: ...st tension hold both left and right focus adjustment knobs with both hands hold the left knob to prevent it from turning and rotate the right knob clockwise to increase tighten or counterclockwise to decrease loosen the focus knob tension After tension adjustment has been completed always rotate both adjustment knobs in the same direction Adjusting Interpupillary Distance Fig 6 Different users hav...

Страница 9: ...sition do this when users change because different users have differing diopters Rotate the magnification selector knob to 3x and rotate the focusing knob to focus on the iris diaphragm Rotate the magnification selector knob to the 1x magnification position and adjust the diopter ring on left eyepiece to focus the specimen repeat for the right eyepiece Adjusting the Bottom Illumination Fig 8 Plug ...

Страница 10: ...pen the baffle by rotating the baffle control knob counterclockwise Inclusions should stand out as dark objects against a bright background Darkfield Illumination Close the baffle by rotating the baffle control knob clockwise The stone is illuminated with diffused light from the sides View the stone against the baffle s black non reflective background Inclusions stand out as bright objects Adjusti...

Страница 11: ...of the darkfield housing is a trap door Open the trap door by loosening the screw see Fig 11 The screw can be loosened by hand or by using the small flathead screwdriver included in the original shipment of the Gem stand The door will open and the lamp can be removed IMPORTANT When replacing the lamp be careful not to touch the new lamp with your fingers as the oils and dirt on your fingers can af...

Страница 12: ...rner of the cover plate using the Phillips head screwdriver that was included with your Gem stand The fluorescent lamp is connected to a socket in the housing by a four pin connector The socket is held in place with a screw Remove the screw from the lamp socket Carefully pull the fluorescent lamp out from the socket by the base of the lamp to avoid accidental breakage Insert the new lamp into the ...

Страница 13: ...objectives Clean objectives Image is not clear while focusing Diopter adjustment is not correct Readjust diopter Focusing is not correct Readjust it The focusing knob is not smooth The focusing knob is too tight Loosen it to a suitable position The image is obscure because of the head slipping down during observation The focusing knob is too loose Adjust the tension on the focus knobs Lamp does no...

Страница 14: ...kmanship for a period of five years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other then ACCU SCOPE approved service personnel This ...