background image

Read and follow all U.L. and Safety Standards before installing any access device.  Please refer to this manual and 

qualified personnel for assistance.  DO NOT install this device unless all entrapment and pinch points are eliminated. 

EZ

  Loop 

Revision 2.5E 

WVD100 

Wireless Vehicle Detector 

ACCESS        STATUS < 
ONE             PROGRAM 

Product Manual 

• 

Installation Instructions 

• 

Program Instructions 

• 

AP100-PA Relay Board 

• 

S200P Sensor 

• 

S600SM Sensor 

Summary of Contents for WVD100

Page 1: ...d qualified personnel for assistance DO NOT install this device unless all entrapment and pinch points are eliminated EZ Loop 1 Revision 2 5E WVD100 Wireless Vehicle Detector ACCESS STATUS ONE PROGRAM...

Page 2: ...Dirt or Gravel 11 Installing The S200P Sensor On A Hill 11 Installing The S200P Sensor In Snow 12 Above Ground Cap 12 Assemble the S200P Sensor 13 S600SM Learn Button 13 Assemble the S600SM Sensor 13...

Page 3: ...Move the Sensor near the AP100 4 Enter the LEARN mode on the AP100 Relay board a Select PROGRAM press Enter b Select SENSOR press Enter c Select LEARN press Enter d AP100 will display SEARCHING e Pre...

Page 4: ...detect a vehicle 4 Place the sensor far enough away from the gate so the moving gate does not activate the sensor Usually 8 10 feet from the gate Quick Start 7 Drill Sensor Hole To prepare the Sensor...

Page 5: ...potential hazards and pinch points have been eliminated Safety Information Restrictions and Limitations Please read and follow all restrictions and understand all limitations Do not install this produ...

Page 6: ...to any existing S200P sensor at any time Distance Chart Refer to the below chart for average distances for the sensor placement from the AP100 antenna Installation Mounting The AP100 The AP100 Relay...

Page 7: ...tenna Line of Sight Because significant signal strength is lost when a sensor is placed in the hole it is very important to install the antenna in a location with a full clear line of sight to every s...

Page 8: ...r 2 4 feet total depth This feature is used to reduce false triggers and help to not pick up a slide gate after the vehicle has cleared Side detection is not reduced and is at full detection distance...

Page 9: ...This diagram is a basic layout and does not show safety devices pedestrian gate fencing etc Refer to the gate operator manual for proper details Most swing gate applications will use a Reverse Sensor...

Page 10: ...mine if one or multiple sensors will be needed for full detection across a wide traffic lane 3 Determine if one or multiple sensors will be needed to cover the detection area outside and inside the pa...

Page 11: ...P Sensor On A Hill Hill applications can be difficult for installation as the hill can create signal loss and require some adjustments to the sensor installation Because of the signal issues that can...

Page 12: ...recessed deep enough that a snow plow will not hit it Make sure to seal the cap so it does not move Screws or anchors are recommended for this application so future access for service is more simple...

Page 13: ...ch the Sensor board 3 Place the antenna face down in the antenna compartment with the antenna wire going through the slot to the Sensor board Green back of the antenna should be seen 4 Place the Senso...

Page 14: ...xy similar to what is used to hold down highway reflectors can be used One source we recommend is https stop painting com order_form asp Stop Painting com AP 43 Epoxy Kit for Road Reflectors One Quart...

Page 15: ...whatever function is desired Each Sensor can be set to activate a single relay or multiple relays and different relay functions can be set for each Sensor For example Sensor1 may be programmed to acti...

Page 16: ...ing then moved to install in its hole the sensor will detect and lock on detect until it is reset A sensor will reset automatically after 14 minutes At that time the sensor will retune itself to its n...

Page 17: ...used Default 100 1 Select PROGRAM press Enter 2 Select SENSOR press Enter 3 Select SENSE press Enter 4 Select SENSORx press Enter x Sensor being programmed 5 Select the X Y or Z setting press Enter 6...

Page 18: ...nking and turn on or off each time the Learn button is pressed Sensor Programming Sensor Park Fail Rev 2 5 CAUTION This is a preliminary feature and has not been fully tested and approved for use Use...

Page 19: ...rns the alarm on off and resets the Fault Status Log Default setting is On To change the setting or clear the Fault Status Log 1 Select PROGRAM press Enter 2 Select AP press Enter 3 Select ALARM press...

Page 20: ...ed when in detection mode For example a vehicle approaching the sensor straight on will not be detected until 1 2 feet from the sensor But when the sensor detects the vehicle it expands the depth to 2...

Page 21: ...nd screen a few seconds later Faults Status Fault status is a log of the last ten faults It tracks the date time and sensor or controller that failed To view the fault log 1 Select STATUS press Enter...

Page 22: ...r1 1 Program the shared Sensor number ACTIVE 2 Delete the shared Sensor number 3 Reset the Sensors and relearn AP100 does not see Sensor detect 1 Make sure the Sensor has been programmed ACTIVE 2 Moun...

Page 23: ...Restrictions and Limitations set forth in this manual 2 A moving gate can cause serious injury or death Read and follow all installation manuals reference manuals and warning label instructions 3 Veh...

Page 24: ...www AccessOneTechnologies com...