background image

!

User Manual 

!

 

AFC400

                              

!

1

Summary of Contents for AFC400

Page 1: ... User Manual AFC400 1 ...

Page 2: ...venotec based on the products described in this manual are based exclusively on the manufacturer s warranty Through technical improvements and innovations the product specifications may deviate from the information given in this manual Abyzz and venotec are registered trademarks Valid 31 07 2017 2 ...

Page 3: ...nings 8 Application and general instructions 9 Installation of driver 10 Installation of pump 11 Quick start 11 Run in phase 12 Description of control elements 12 Usage 13 Service 15 Warranty 16 Technical changes 17 Troubleshooting 18 Disposal 19 Technical data 20 Components and materials 20 Appendix 22 ff 3 ...

Page 4: ...g time please read this manual carefully and adhere to our recommendations If the quality of your product does not meet your expectations please contact the dealer from whom you have purchased this product or do not hesitate to contact us directly We recommend that you register your product with the enclosed form so that we can offer you the best service Please make sure that you keep the serial n...

Page 5: ... models come with a set of registration documents for warranty and service purposes 1 Abyzz AFC400 pump with 10m cable 1 Abyzz AFC400 driver 1 Abyzz connection cable for Abyzz peripherals 1 Abyzz power cable 1 User manual 5 ...

Page 6: ...life and meet the highest requirements and quality standards The products were developed and manufactured in Germany This is our understanding of Made in Germany The electronic control unit offers optimum operating characteristics These include in particular Adjustable speed range 0 100 Programmable control Dry running warning Smooth start Busable interface Lockable plug in contacts Temperature pr...

Page 7: ...peratures etc are displayed centrally on the ACS There are two D Sub connectors on the bottom of the Abyzz drivers The connection labeled Master is always connected in the direction of the ACS the connection Slave always in the direction of the next Abyzz pump Abyzz Interface AInt With the Abyzz interface we offer you the possibility to integrate your Abyzz pumps into a control system PLC aquarium...

Page 8: ...ssociated with each other Keep the leads plugs and drivers dry and protect the components from damage Never work with wet hands on the cabling or on the driver Operate the product only if there are no persons in the water or persons have contact with the water Check the product for damage and never use a visibly damaged product Only connect Abyzz devices to suitable sockets with protective contact...

Page 9: ...n the dirty water regular cleaning and the use of a pre filter are required to protect the pump In this case the internal flushing channel must be cleaned Abrasive components increase wear damage is not covered by the warranty The pump must always be installed below the water level Please observe the generally applicable national and international regulations during installation The maximum workin...

Page 10: ...n several drivers at the same time due to the driver s inrush current Do not use multiple sockets and do not exceed the permissible power supply of your cable Ambient temperature and cooling The product can be used at ambient temperatures of 2 C to 35 C To ensure sufficient cooling the driver should have a minimum distance of 30cm from objects walls ceilings cable ducts pipes etc to the top of the...

Page 11: ...ce the fuses Installation of pump The Abyzz pump can only be operated up to a depth of 0 5 8 meters The mounting can be carried out via the optionally available accessories please contact our sales department info abyzz de Installation must be carried out by qualified personnel Quick start After proper installation the Abyzz pump can be put into operation Connect the motor cable to the driver The ...

Page 12: ... control elements Display The display informs you about the operating state of the pump The display goes into a quiet mode after 3 minutes to allow maximum service life and lowest power consumption Pressing a key again turns the display back on The overview changes as follows every 2 seconds and displays the following operating data Performance in Operating mode Perm Random Random 2 Wave Internal ...

Page 13: ...the operating hours and the operating mode are displayed consecutively Furthermore the driver address can be displayed and deleted The contrast of the display can be set in the corresponding overview by holding down the Start Stop key and pressing the Up or Down keys If you wish to change the operating mode press the Start Stop key when the operating mode is displayed You can now set the operating...

Page 14: ...ating mode press Start Stop You are then asked to enter the corresponding data minimum and maximum power time interval Confirm each setting with Start Stop Finally the settings are saved automatically and you return to the overview 14 ...

Page 15: ...eassembling new self locking nuts must be used The protective grille can then be pulled backwards and the motor can be cleaned P10 If it is necessary to remove the impeller unscrew the retaining screw P8 with a suitable hexagon socket wrench and pull the impeller from the shaft This screw is made of titanium and must not be replaced by another screw The rear bearing can be inspected by opening the...

Page 16: ...above and beyond compensation for the product itself or damage resulting from improper use negligence incorrect installation or interventions and changes carried out by unauthorized persons We expressly exclude such scenarios from our scope of liability Any secondary damages such as the loss of coral fish or water damage caused by pump failure or a lack of intake protection are expressly excluded ...

Page 17: ... Technical changes Due to continuous development and innovation which in particular serve the quality safety and progress the manufacturer reserves the right to technical modification 17 ...

Page 18: ...ton Display off LED off a No power b Fuse blown a Check power chord b Replace fuse If the fault can not be remedied fuses are always faulty there is an error in the driver In this case please contact the service Status COMM FU a No internal communication a Switch off driver and wait 10 sec before switching on again Status Imax a Current protection a Check motor for blockades Status MOTOR a Pump de...

Page 19: ...Germany free of charge and to take over the appropriate recycling or disposal The corresponding WEEE number at the EAR is DE 16546900 If you do not dispose of the product by us you accept the duty of disposal according to the legal regulations at your own expense and release us from the obligation pursuant to 10 2 ElektroG and related claims from third parties 19 ...

Page 20: ...0 l h Discharge speed maximum 3 3 m s Power consumption 4 400 W Operating voltage 230V 50 60Hz 100 120V 50 60Hz optional Components and materials The following substances are used in conjunction with the medium to be conveyed ABS GF 20 PVC WCNi Titan Gd 2 SSIC NBR CR EPDM PU 20 ...

Page 21: ...elevant provisions EC Directive 2014 30 EU Applied harmonized standards DIN EN 61000 6 1 DIN EN 61000 6 2 DIN EN 61000 6 4 DIN EN 61000 3 2 These devices are Class A devices In residential environments these devices may cause radio interference In this case the user is responsible for taking appropriate measures 21 ________________ Alexander Grah CEO ...

Page 22: ... Appendix P1 P2 22 ...

Page 23: ... P3 23 ...

Page 24: ... P4 24 ...

Page 25: ... P5 P6 25 ...

Page 26: ... P7 P8 26 ...

Page 27: ... P9 P10 27 ...

Page 28: ... 28 ...

Page 29: ... 29 ...

Page 30: ... WWW ABYZZ DE 30 ...

Reviews: