background image

 

 

 

 

 

PLBE10000 

Nexello keypad 

 

 

 

 

 
 
 
 

Important notes and FAQs about this product and other products can 

be found on the website 

www.abus.com

 

 

 

 

Manual version: 1.1 

firmware version: 1.35 

 

 

Summary of Contents for PLBE10000

Page 1: ...PLBE10000 Nexello keypad Important notes and FAQs about this product and other products can be found on the website www abus com Manual version 1 1 firmware version 1 35 ...

Page 2: ...ffing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 Fri 08 14 All company names and product designations contained herein are trademarks of their respective owners All rights reserved Disclaimer This operating manual has been prepared with the utmost care Should you nevertheless notice any omissions or inaccuracies please notify us in writing at the ...

Page 3: ...vidual units Ensure that there is always sufficient ventilation that no direct heat sources act on the device that no direct sunlight or strong artificial light falls on devices for indoor use that the device is not in the immediate vicinity of magnetic fields e g loudspeakers that no open fire sources e g Do not stand on or next to the device avoid contact with splashing or dripping water on devi...

Page 4: ...eaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use only suitable microfibre cloths for high gloss surfaces Make sure that no water gets inside the device Do not put the appliance in the dishwasher Do not use any sharp pointed abrasive caustic cleaning a...

Page 5: ...ers 8 1 7 DSK code 8 2 Functional overview 9 2 1 Inclusion Teach in device 9 2 2 Planning assembly and installation 10 2 3 Exclusion teach in device 11 2 4 Resetting the factory settings 11 2 5 System status 11 2 6 Code entry 12 3 Advanced Z Wave Parameters 13 3 1 Association Groups 13 3 2 Reports 14 3 3 Configuration parameters 15 3 4 Supported command classes 16 3 5 Supported security levels 16 ...

Page 6: ...of the keypad when approaching and automatic control of the key illumination C LED display Status display for various processes see 1 3 D Speaker For acoustic signalling of keystroke status and feedback signals E Battery compartment Observe polarity F Sabotage contact Triggers sabotage alarm G Keys For entering codes activating and deactivating and triggering a panic alarm H Link Button Manual tri...

Page 7: ...red code with the command to activate Emergency alarm Long pressure sends emergency alarm for e g panic alarm or medical emergency 1 4 Operating principle The device was developed for use in alarm and home automation systems that use the Z Wave wireless standard The device has the following functions Code entry The numbers can be used to send codes to a Z Wave controller These code entries can be ...

Page 8: ...ss Control Security Class The command classes are supported only when the Access Control Security Key has been granted therefore an S2 security enabled controller is required to operate the product 1 7 DSK code The DSK code Device Specific Key is the device specific key of your device and is required for secure inclusion teach in via S2 on the Z Wave controller The first 5 digits known as the PIN ...

Page 9: ... support SmartStart follow these instructions for Product Classic Inclusion Activate the inclusion mode teach in mode on the Z Wave controller for more details please refer to the Z Wave controller s user manual Or press the button Include Add in your Z Wave app and follow the instructions to set the Z Wave controller to include mode Keep the device within range of the Z Wave controller Press the ...

Page 10: ...limit the range The device has a radio range of up to 40 m indoors The battery life of the device is reduced if the wireless connection to the Z Wave controller is not direct but via a repeater Select installation location The device is only suitable for indoor installation Assembly instructions Fix the rear panel of the keypad firmly to the wall with screws and dowels Then carefully place the fro...

Page 11: ...sful exclusion is displayed in the app or on the Z Wave controller and the link LED on the device lights up green 2 4 Resetting the factory settings Press and hold the Link button for at least 5 seconds The device is now reset to factory settings Hint Please use this procedure only if the primary network controller is missing or otherwise not functional If the device is set to factory default the ...

Page 12: ... set duration Output delay Beeps for a set duration Invalid code Flashing 3 times briefly Beeps 3 times briefly 2 6 Code entry First enter the assigned code by pressing the keys on the keypad and then acknowledge the code with the acknowledgement keys e g activate system The keypad transmits the code together with the command and checks whether the necessary authorizations are available If the cod...

Page 13: ...triggering of a sensor When this event occurs a control command usually a BASIC SET is sent to all devices stored in an association group The device supports one association group Group Number Maximum Devices Group name Profile command class Group 1 5 Lifeline General Notification report Battery report Device Reset Locally Notification Entry control Group 1 Association Z Wave Controller The Lifeli...

Page 14: ...x00 Sabotage alarm acknowledgement 0x07 0x00 0x01 0x03 Battery alarm replace soon 0x08 0x0A 0x00 Battery alarm replace now 0x08 0x0B 0x00 Battery alarm acknowledgement 0x08 0x00 0x01 0x0A 0x0B battery report Value Description 0x05 0x64 5 100 Battery charge level in percent 0xFF 256 Low battery Indicator Get Report Value Description 0x00 0 No state 0x01 1 Internally active 0x02 2 Active 0x03 3 Deac...

Page 15: ...tween two motion alarms 5 Waiting time from one motion alarm to the next triggering Adjustable from 2 30 in seconds Hexadecimal 0x02 0x1E 5 1 Proximity sensor Sensitivity 9 Sensitivity value of the proximity sensor The value 31 is the lowest sensitivity The value 4 is the highest sensitivity Adjustable from 4 31 Hexadecimal 0x00 0x0A 6 1 Light sensor Active Deactive 1 Activate deactivate the light...

Page 16: ...ntry control Version 1 Firmware Update Md Version 5 Indicator Version 3 Manufacturer Specific version 2 Multi Channel Association Version 3 Notification Version 8 Power level Version 1 Security Version 1 Security 2 Version 1 Supervision Version 1 Transport Service version 2 Version Version 3 Z Wave Plus Info version 2 3 5 Supported security levels Security S2 Access Security S0 Authenticated ...

Page 17: ...Type of battery 2x CR123A Battery life 12 months Sabotage protection Yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0004 Z Wave Device ID 0x0001 Z Wave SmartStart supported Yes Z Wave Plus supports Yes Z Wave Network Security Yes Z Wave AES 128 Security S0 Yes Z Wave S2 Security Yes S2 Authenticated Z Wave Chip Generation 700 Z Wave Device Type secure keypad...

Reviews: