background image

Firmware Ver. A/B and Ver. C/B

LGS-1100-H

Abrams Logic 1100 Programmable Handheld

Siren System & Light Controller

NOTICE TO INSTALLER

Before installation and operation

 ― 

read all instructions and warnings.

Deliver this manual to the end user of this product.

Summary of Contents for Logic 1100

Page 1: ... C B LGS 1100 H Abrams Logic 1100 Programmable Handheld Siren System Light Controller NOTICE TO INSTALLER Before installation and operation read all instructions and warnings Deliver this manual to the end user of this product ...

Page 2: ...in the manual from the original manufacturer 6 The operator should verify the siren system is fastened to the vehicle securely and is functioning properly Failure to follow all safety precautions and instructions may cause property damage injury or death 7 Ensure that any switch control panel is located in an area that allows both the vehicle and the control panel to be operated safely in any driv...

Page 3: ...00 Watts Siren Output Load 100W ACR 11Ω Siren Frequency 758Hz 1587Hz 447Hz 596Hz HI LO Max Current 10A 12VDC 5A 24VDC w o light control outputs 30A 12VDC 25A 24VDC w 4x light control ouputs Standby Current w o IGN wire 4 5 mA 12V 10 mA 24V w IGN wire 0 37 A 12V 0 28 A 24V Operating Temperature Range 30 65 Light Controls 4x 5A light control outputs Fuse Ratings Built in 5A blade fuse on each of the...

Page 4: ...OUT PINK HORN RING TRANSFER HRT INPUT GREY RADIO IN WHITE RADIO IN RADIO SPEAKER OUTPUT BLUE SPK OUT FEET American Wire Gauge METERS IEC 60228 2004 Standard Wire Cross Section 10A 20A 30A 40A 22AWG 20AWG 18AWG 16AWG 14AWG 12AWG 10AWG 6AWG 8AWG 3 5 7 5 12 19 5 31 49 124 Ins 4 6 9 5 15 5 24 5 62 Ins Ins Ins 4 6 5 10 5 16 5 41 5 Ins Ins Ins 3 5 7 5 12 5 31 Ins 78 39 26 19 5 Ins Insufficient 10A 20A 3...

Page 5: ...e system does not operate without this Ignition Activation DO NOT directly connect this wire to the battery as this may drain battery SW1 Output Connect to auxiliary device power up to 5 Amps max or use as Lightbar function activation switch SW2 Output Connect to auxiliary device power up to 5 Amps max or use as Lightbar function activation switch SW3 Output Connect to auxiliary device power up to...

Page 6: ...ill de activate the Radio Rebroadcast upon activation It may be interlocked by SW1 See Siren Interlock Horn Disable Setting section for more details RADIO Activate Radio Rebroadcast through the siren speaker This button will de activate the Siren Tone upon activation SW1 Activate SW1 Output It may be used for the primary warning light and interlocking SIREN SW2 SW3 and or SW4 See Siren Interlock H...

Page 7: ...8 761 1592 761 1592 761 1592 450 598 761 1592 761 1592 761 1592 450 598 WAIL 12 C M YELP 158 C M HILO 40 C M PHASER 886 C M 761 1592 761 1592 450 598 761 1592 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 FRANCE FRANCE FRANCE FRANCE FRANCE GERMANY AUSTRIA AUSTRIA AUSTRIA AUSTRIA ITALY ITALY ITALY NETHERLANDS NETHERLANDS GENDARMERIE POLICE AMBULANCE POMPIERS UMH STADT LAND POLICE AMBULANCE FIREBRIGADE...

Page 8: ...SW3 SW4 5 3 1 2 7 8 4 6 Green Red Siren Interlock Horn Disable Setting 1 Press and hold PTT MAN and SIREN for 5 seconds to enter Siren Interlock Horn Disable Setting SIREN will blink to indicate that you are in Siren Interlock Horn Disable Setting 2 While in Siren Interlock Horn Disable Setting press RADIO or SW1 or SW2 or SW3 or SW4 buttons to switch between different settings See Indication Char...

Page 9: ...may be set as a ON OFF switch a Momentary switch or a Timer switch 1 Press and hold PTT MAN and Code 3 for 5 seconds to enter SW Button Type Setting 2 If any of the button type is not in its default setting ON OFF an auto clearing will be performed with a full blinking of the controller 3 Code 3 will blink to indicate that you are in SW Button Type Setting the button type of each SW1 4 button is i...

Page 10: ...ting clip as a template mark the two holes to be drilled 3 Drill two mounting holes for sheet metal screws 4 Install the microphone clip with provided sheet metal screws 126 4mm 4 98 136 2mm 5 36 126mm 4 96 90mm 3 54 Top view INSTALLATION WARNING PINCH HAZARD Steel iron and or other ferrous objects may be attracted suddenly and forcefully to the magnets creating the risk of pinch type injuries Kee...

Reviews: