background image

 

16-X1 

Cellular Telephone Entry System

Installation and  

Operating Manual

www.americanaccess.com

Your 

“Partner”

 in Access Con

trol

Summary of Contents for Ascent X1

Page 1: ...16 X1 Cellular Telephone Entry System Installation and Operating Manual www americanaccess com Your Partner in Access Control ...

Page 2: ... Codes Sub Mode 1 10 Delete Individual Access Codes Sub Mode 2 11 Change the Master Code Sub Mode 3 11 Set Sleep Code Sub Mode 4 12 Set Latch Code Sub Mode 5 13 Set Relay Output Times Sub Mode 6 13 Program Relay B Access Codes Sub Mode 7 13 Enable or Disable the Three Strikes You re Out feature Sub Mode 8 14 Event Input Sub Mode 9 15 Erase All Codes Sub Mode 0 16 RESETTING THE X1 UNIT 17 Master Re...

Page 3: ...f purchase Contact the original dealer or installer of the product and return your AAS product along with the receipt to them If you have problems locating the dealer or installer contact American Access Systems at 303 799 9757 and we will direct you to an AAS authorized dealer or distributor If you ship your AAS product you must prepay all shipping charges We suggest that you retain your original...

Page 4: ...n Transformer 4 20 X carriage bolts 4 20 hex nuts Tools Needed For Basic Installation Wire nuts or appropriate terminals connectors Wire strippers Wire cutters 3 8 drive ratchet 6 extension 7 16 socket Digital or Analog multi meter 1675 West Yale Ave Englewood CO 80110 phone 303 799 9757 fax 303 799 9756 sales securitybrandsinc com www securitybrandsinc com SECURITY BRANDS INC Technical Customer S...

Page 5: ...orating both normally open N O and normally closed N C contacts An external event trigger programmable as a Remote Inactive Arming or Remote Open input INSTALLATION MOUNTING THE UNIT The tools and instruments needed to install your unit are shown on the Parts Checklist are shown on page 4 Make sure you have all the tools listed before you begin It s a good idea to make sure to check off the items ...

Page 6: ... you are connecting to a gate operator Overhead door or electric door strike use the COM and N O terminals for normally open contact b If you are connecting to a mag lock or any device that requires power in the continuous state use the Primary Relay A COM and N C terminals for normally closed contact 4 If you are using a Free Exit push button device requiring the Ascent X s relay A or Relay B out...

Page 7: ... CODE The Master Code is a four digit Function Code used to program Access Codes into the Asecnt X unit The factory default master code is 1 2 5 1 The Owner Administrator enters the Master Code to program the Access Codes others will use to gain entry to the area controlled by the unit It is recommended that the Master Code be re programmed to a four digit code of your choice Remember to make a no...

Page 8: ...by entering the Master Code using the keypad If the correct Master Code is entered the unit will reply with a GOOD TONE and the Yellow LED will illuminate In the Program Mode you have approximately 30 seconds between key presses If the 30 second time period is exceeded during programming the unit will automatically exit the Programming Mode No damage is done to the programming Simply complete the ...

Page 9: ...ight and a GOOD TONE will sound You can now enter any of ten programming SUB MODES described below SUB MODE NUMBER CODE DESCRIPTION 1 Program an Access Code s Relay A 2 Delete an Access Code 3 Change Master Code 4 Set Sleep Code 5 Set Latch Code 6 Set Relay Output Times 7 Program an Access Code s Relay B 8 Enable Disable the 3 Strikes You re Out Feature 9 Program Event Input 0 Erase Memory ...

Page 10: ...assigned and you must select another code If you make a mistake during entry press the star key then re enter the code When a new code is accepted the unit will sound a GOOD TONE Continue to enter codes until you are finished When you are done press the pound key to exit the programming mode NOTES You will automatically be exited from the programming mode IF The memory reaches capacity The memory ...

Page 11: ...in memory the unit will respond with an ERROR TONE and wait for another code to be entered A GOOD TONE will sound once the code has been found and deleted You may continue deleting codes until you are done then press the pound key to exit the programming mode Change the Master Code Sub Mode 3 To change the Master Code Enter the current Master Code Unit will sound a GOOD TONE Press the numeral 3 En...

Page 12: ...l flash every 3 seconds To initialize the system back tonormal simply re enter the Sleep Code Should you lose or forget the Sleep Code and the unit is in the sleep mode you must complete a Master Reset See the instructions on page 18 To program or change the Sleep Code Enter the current Master Code Press the numeral 4 Unit will sound a GOOD TONE Enter a new Sleep Code If you hear an ERROR TONE sel...

Page 13: ... Code is accepted you will hear a GOOD TONE Press the pound key to exit the programming mode Now when the new Latch Code is entered the RED LED will light and the gate will hold open When the new Latch Code is entered a second time the RED LED will go off and the gate will close NOTE On gates with a closing timer the TIMED DURATION begins when the Latch Code is released Set Relay Output Times Sub ...

Page 14: ... unit will revert to the IDLE MODE and will operate normally To toggle the Three Strikes You re Out feature on or off Enter the current Master Code Unit will sound a GOOD TONE Press the numeral 8 and the unit will respond with either one or two tones A single tone indicates the Three Strikes You re Out will be enabled A double tone indicates the Three Strikes You re Out will be disabled Unit will ...

Page 15: ...s an Arming Circuit Enter the MASTER CODE Unit will sound a GOOD TONE Enter the numeral 9 Unit will sound the Current Mode followed by a GOOD TONE Enter the numeral 2 Unit will sound a GOOD TONE 3 To program the Event Input as Remote Open Enter MASTER CODE Unit will sound a GOOD TONE Enter the numeral 9 Unit will sound Current Mode followed by a GOOD TONE Enter the numeral 3 Unit will sound two qu...

Page 16: ...rase all Access Codes entered This action will not change the Master Code To erase all Access Codes and Function Codes Enter the Master Code The 1 2 5 1 cannot be deleted Enter the numeral 0 Both the Red and Yellow LEDs will flash several times and the unit will sound a GOODTONE once all of the memory is cleared Enter the Master Code to complete the process If the sequence is not validated by the ...

Page 17: ...Master Code to the 1 2 5 1 Should be used if the unit is in the Latch or Sleep Mode and the Latch or Sleep code is lost or forgotten When a Master Reset is performed Access Codes and Functions Codes are retained in memory and the unit does not require complete reprogramming Unit Reset Should only be used if the Ascent X1 is to be completely reset back to factory default settings ALL ACCESS and FUN...

Page 18: ... ALL ACCESS CODES and FUNCTION CODES are lost when performing a Unit Reset Follow these steps exactly If you make an error an ERROR will occur a low pitch ERROR tone will sound and you will need to start over from Step 1 1 Open the faceplate 2 Disconnect the power from the unit by gently pulling the wire harness away from the board Make sure to note the orientation of the connector 3 Press and hol...

Page 19: ... timer circuit from overriding the keypad when it is in a latch mode Contact Gate Operator manufacturer When I enter a valid Access Code the gate does not open Locate the two wires attached to the Brown and Orange wires on the main wire harness then touch them together If the gate does not open check wiring or the connection terminals on gate operator If the gate opens contact American Access Syst...

Page 20: ... our Technicians assist you E Mail customerservice securitybrandsinc com Technical Support 303 799 9757 Technical support is available free of charge Hours are 8 00 a m to 4 30 p m MST If you call please have your Model and Serial Number to help our Technicians assist you E Mail techsupport securitybrandsinc com 1675 West Yale Ave Englewood CO 80110 phone 303 799 9757 fax 303 799 9756 sales securi...

Page 21: ...Page 21 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code ...

Page 22: ...Page 22 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code ...

Page 23: ...Page 23 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code ...

Page 24: ...Your Partner in Access Control www securitybrandsinc com SECURITY BRANDS INC ...