Page 1: ...Aarrow Stove User Guide Aarrow Stove User Guide December 2015 BS EN 13240 2001 A2 2004 CE BK530 Rev13...

Page 2: ...ld provide a lifetime of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical supp...

Page 3: ...our stove 8 5 1 Smoke Control Zones 8 5 1 1 Refuelling on to a low fire bed 8 5 1 2 Fuel overloading 9 5 1 3 Operation with door left open 9 5 1 4 Dampers left open 9 5 2 Burning wood 9 5 3 Burning so...

Page 4: ...ted heat 17 9 Ongoing care for your Aarrow stove 18 9 1 Adjusting the door hinges 18 9 2 Liners firebricks 18 9 3 Throat plate 19 9 4 Fire door seal 19 9 5 Cracked glass 19 10 Further resources readin...

Page 5: ...ernment approved competent persons scheme such as operated by HETAS If in doubt contact HETAS Limited telephone 01684 278170 or visit www hetas co uk A fireguard conforming to BS 8423 2002 should be u...

Page 6: ...ained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and...

Page 7: ...e both the chimney and the appliance and increase the risk of a chimney fire 2 2 Solid fuel If you have chosen a multi solid fuel stove this will have a cast iron riddling grate which allows you to bu...

Page 8: ...ned to help you get the best from your Aarrow stove Always wear suitable protective fire gloves when refuelling your stove such as the Arada glove supplied with your stove We recommend that you light...

Page 9: ...ase of the fire chamber and the airwash system secondary air provides overdraught and airwash jets The exact controls may differ from those illustrated in this manual but will work in the same way Fig...

Page 10: ...e air wash control for ECB5PLUS SC and ECB7PLUS SC cannot be fully closed This is to prevent shut down of the appliance 4 2 i Series air controls 4 2 1 i Series Cassette Stoves The Aarrow i Series cas...

Page 11: ...Aarrow Stove User Guide Figure 2 i Series air inlet controls BK530 Rev13 7...

Page 12: ...e check the data plate before operating in a Smoke Control Zone to ensure it is a compliant product indicated by the letters SCE or just SC following the product name The i400 400 T F SCE i500 SCE i60...

Page 13: ...y of air coming from above the fuel For this reason we will use all the air inlets while igniting the stove but will then reduce this to air coming from the airwash system and over draught As much as...

Page 14: ...se the primary air control on non i Series stoves as generally no air from below the grate is required when burning wood 5 3 Burning solid fuels If you have an i Series stove please read section 5 4 o...

Page 15: ...e airwash should be opened sufficiently to keep the door glass clean Whilst burning solid fuel it can be beneficial to occasionally riddle the grate bars so any burnt fuel will fall between the grate...

Page 16: ...y sliding it to the right see instructions on page 6 3 Light as with wood see steps 2 3 and 4 on page 9 with kindling and fire lighters 4 Once flue draw has been established after about five minutes c...

Page 17: ...from your HETAS registered installer Do not attempt to re light the fire until the cause of the fume emission has been identified and corrected 5 5 1 Refuelling on to a low fire bed If there is insuf...

Page 18: ...e Firing the stove at maximum for prolonged periods may result in over firing If the chimney connector or casing glows red the appliance is being over fired and this may result in a chimney fire 6 3 P...

Page 19: ...The ash pan should be emptied when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up to touch the underside of the grate bars as this will greatly re...

Page 20: ...ends marked L sitting on the low sections The riddling lever either on the side or front of your stove can be operated with the stove operating tool to riddle ash into the ash pan below Only riddle th...

Page 21: ...heat the objects they strike It is then these objects such as the chimney breast hearth etc which heat the surrounding air 8 2 Convected heat Air immediately adjacent to the stove is heated as a resu...

Page 22: ...erture or catch This is quite normal and due to the settling of the casting Doors attached with two hinges fixed to the body with screws can be re aligned as follows When the appliance is cold open th...

Page 23: ...r ability to control the burn rate and its efficiency whilst leading to an increase in heat lost through the flue 9 5 Cracked glass It is not recommended to operate the stove with cracked glass this c...

Page 24: ...ted articles HETAS www hetas co uk Solid Fuel Association www solidfuel co uk Document J Building Regulations Combustion Appliances www planningportal gov uk The National Association of Chimney Sweeps...

Page 25: ...Arada stoves Non boiler Aarrow and Villager stoves come with a lifetime guarantee Non boiler Hamlet stoves come with a ten year guarantee Stratford and Villager boiler stoves come with a five year gua...

Page 26: ...hether this condition has been satisfied shall be final 7 The guarantee does not cover damage caused to the stove through careless handling or misuse or neglect of the appliance misuse and neglect bei...

Page 27: ...rable and solely for the benefit of the original purchaser of the stove 11 3 General Our guarantee is offered as an addition to your statutory rights and will not affect your statutory rights You can...

Page 28: ...Aarrow Stove User Guide This page is left intentionally blank BK530 Rev13 24...

Page 29: ...Aarrow Stove User Guide Manual last updated December 2015 Arada Ltd 2015 T 44 0 1297 35700 info aradastoves com Arada Ltd Weycroft Avenue Axminster Devon EX13 5HU www aradastoves com BK530 Rev13...