background image

1

#3MScienceofSafety   

|

© 3M 2020. 3M Confidential.

1

2017

© 3M

#3MScienceofSafety   

|

3M Powered Air 

PAPR Cleaning / 

Sterilisation

Work in a World 

of Comfort

Summary of Contents for Versaflo S Series

Page 1: ...1 3MScienceofSafety 3M 2020 3M Confidential 1 2017 3M 3MScienceofSafety 3M Powered Air PAPR Cleaning Sterilisation Work in a World of Comfort...

Page 2: ...ecific contaminants to which you have been exposed Do not use detergent that contain lanolin or other oils Do not use sterilisation processes e g ethylene oxide radiation and steam sterilsation Always...

Page 3: ...uid household soap Do not soak headtop Plastic parts can be submerged remove sweat pad first Sweat pad can be hand washed or laundered Optional wipe outer surface with hospital detergent disinfectant...

Page 4: ...ScienceofSafety 3M 2020 3M Confidential Cleaning S Series Headtops continued Do not wipe with wipe faceshield with strong solvents MEK acetone toluene Do not wash in a washing machine or respirator wa...

Page 5: ...with clean cloth sponge dampened with warm water liquid household soap can be submerged Optional wipe outer surface with hospital detergent disinfectant Repeat wipe down with warm water liquid househ...

Page 6: ...hospital detergent disinfectant Repeat wipe down with warm water liquid household soap High durability outer shroud can be laundered or wiped Optional wipe outer surface with hospital detergent disinf...

Page 7: ...M 2020 3M Confidential Cleaning M Series Headtops continued Inner collar can be laundered Do not use chlorine bleach or fabric conditioner Do not clean the following Flame retardant headcover Head nec...

Page 8: ...hospital detergent disinfectant Repeat wipe down with warm water liquid household soap Wipe turbo unit and belt with clean cloth sponge dampened with warm water liquid household soap Do not submerge...

Page 9: ...fall down away from turbo Do not attempt to clean filters Remove battery pack and wipe with clean cloth sponge dampened with warm water liquid household soap Do not submerge Carefully clean around pi...

Page 10: ...it and belt with clean cloth sponge dampened with warm water liquid household soap Do not submerge turbo Cleaning solution must not enter the turbo unit Optional wipe with hospital detergent disinfect...

Page 11: ...11 3MScienceofSafety TR 600 Features Easy Clean Decon showers IP53 during use 0 60 from vertical Rinse or Submerge for cleaning IP67 TR 653 Cleaning and Storage Kit required...

Page 12: ...ion With TR 653 Cleaning Storage Kit Ingress Protection IP rating of Do not exceed water temperature of 50 C Inspect gaskets prior to each use Replace gaskets every 30 washes or yearly Do not submerge...

Page 13: ...ge dampened with warm water liquid household soap can be submerged Optional wipe outer surface with hospital detergent disinfectant can be submerged Repeat wipe down with warm water liquid household s...

Reviews: