Instructions for the assembly of 3M

TM 

Ribbon 

Cable Wiremount Socket Assembly, 451 
Series

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Instruction Guide 

March 2022 

78-9102-1086-9_C 

Содержание 3443-81 Series

Страница 1: ... g e 1 8 3M Instruction Guide 3MTM Locator Plate 3443 81 XX 3D Printed Instructions for the assembly of 3MTM Ribbon Cable Wiremount Socket Assembly 451 Series Instruction Guide March 2022 78 9102 1086 9_C ...

Страница 2: ... 1K Shut Height Setting 3MTM Assembly Press 3640 3316 3MTM Assembly Press 3335 45104 3443 81 04 3442 9 7 7 5 45106 3443 81 06 3442 9 7 7 5 45108 3443 81 08 3442 9 7 7 5 45110 3443 81 10 3442 9 7 7 5 45112 3443 81 12 3442 9 7 7 5 45114 3443 81 14 3442 9 7 7 5 45116 3443 81 16 3442 9 7 7 5 45120 3443 81 20 3442 9 7 7 5 45126 3443 81 26 3442 9 7 7 5 45130 3443 81 30 3442 9 7 7 5 45134 3443 81 34 3442...

Страница 3: ...the press shaft and the 3MTM Assembly Press 3830 is self adjusting 3 1 The shut height adjustment is made from the base of the assembly press without the locator plate or platen in place 3 2 Lower the handle of the press until the handle casting makes contact with the press casting See Figure 2 3 3 Place the shut height gauge across the press base See Figure 2 Figure 2 3 4 Rotate the shut height t...

Страница 4: ...Add platen by positioning it parallel with the connector body and cover See Figure 9 Figure 5 4 0 Procedures for Cable Preparation Before assembly of the connector can take plate the cable must be prepared 4 1 Place the cover into the locator plate See Figure 6 Figure 6 4 2 Place the properly sized ribbon cable into the cover in the locator plate See Figure 7 Figure 7 ...

Страница 5: ...fying the pin 1 indicator is in the correct position See Figure 8 Figure 8 5 2 Bring the handle of the press down until the IDC s press into cable and the connector fully seats into the cover See figure 9 Figure 9 5 3 Visually inspect termination to ensure that a Cover is fully seated and parallel to the body b Cable is properly aligned with the cover c Cover retaining devices on the body are flus...

Страница 6: ...e 6 8 Figure 10 Metal fixture shown 6 0 Strain Relief Attachment 6 1 Fold the cable back over the cover See Figure 11 Figure 11 6 2 Place the strain relief in the connector over the cable sliding the strain relief into the slots of the connector See Figure 12 Figure 12 ...

Страница 7: ...M Instruction Guide 3MTM Locator Plate 3443 81 XX 3D Printed P a g e 7 8 6 3 Press the strain relief down until the strain relief snaps into the correct position on the connector See Figure 13 Figure 13 ...

Страница 8: ...uct and determining whether it is fit for a particular purpose and suitable for user s method of application Warranty Limited Remedy and Disclaimer Unless an additional warranty is specifically stated on the applicable 3M product packaging or product literature 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product 3M MAKES NO OTHER WARRANTI...