background image

Installing the Cable

The SuperStack II Advanced RPS and its 
modules may be hot-connected to SuperStack 
II units.

Connecting Cables

Before attaching the cables, check that the 
power demand of the product does not 
exceed the capacity of the Power Module you 
are connecting. This information is given in the 
Power Module user guide 
(DUA1607-4AAA0X), your Advanced RPS 
Chassis user guide (DUA1607-0AAA0X) and 
the product user guide. If you are unable to 
find the information or are unsure, please 
contact your supplier.

Redundancy

Use a standard Type 2 DC cable (as supplied 
with your power module) to provide managed 
redundancy connecting the outlet of the Type 
2A Power Module to the RPS socket on the 
rear of the SuperStack device. The device you 
are connecting must be one with the 
auto-enable feature present for this 
redundancy.

Full Redundancy

Use the Type 2 ‘Y’ cable to provide full 
redundancy (resilience) connecting one short 
lead to each of the two Type 2A Power 
Module outlets installed in the RPS chassis and 
the long lead to the RPS socket on the rear of 
the SuperStack device. 

After installing the cable, this guide should be 
stored with your other 3Com user guides.

Fault Diagnosis

The LEDs on the front of the Advanced RPS 
Chassis provide simple at-a-glance fault 
diagnosis of the installed Power Modules.

If you suspect a problem:

Check that you have allowed at least five 
seconds for the Power Module to warm 
up.

Check the status of the LEDs on the front 
panel of the chassis, as described in the 
SuperStack II Advanced RPS User Guide, 
part number DUA1607-0AAA0X. 

Ensure the Power Module is correctly 
installed in the Chassis.

Check the RPS cables are correctly engaged 
and locked.

If you cannot rectify the fault, contact your 
supplier, giving the following information:

the product number.

the Power Module serial number.

a brief description of the fault.

Your supplier will advise you on your next 
course of action.

DISCLAIMER

Information in this document is subject to change without notice and 
does not represent a commitment on the part of 3Com Technologies. 
3Com Technologies reserves the right to revise or change this document 
without obligation of 3Com Technologies to notify any person of the 
revisions or changes. Information contained in this document is believed 
to be accurate at the time of publication but no liability whatsoever can 
be accepted by 3Com Technologies arising out of any use of this 
information.

This document, or any part of it, must not be copied or reproduced on 
any medium without the prior consent of 3Com Technologies.

In the unlikely event that this product is found to be damaged on arrival, 
or fails to function once installed, you should contact your distributor or 
reseller for advice.

ACKNOWLEDGEMENTS

3Com and SuperStack  are registered trademarks of 3Com Corporation. 
Registered trademarks are registered in the United States, and may or 
may not be registered in other countries.

Other brand and product names may be registered trademarks or 
trademarks of their respective holders.

Part Number: DUA1607-8AAA02

Revision: 00

Issued: August 2000

© 2000 3Com Technologies

S

UPER

S

TACK

®

 II A

DVANCED

 RPS 

T

YPE

 2 ‘Y’ C

ABLE

 

(3C16078)

U

SER

 G

UIDE

Introduction

The SuperStack

®

 II Advanced Redundant Power 

System (ARPS) provides redundant power 
supplies to products in the 3Com SuperStack II 
range. These optional Type 2 Advanced RPS ‘Y’ 
cables (3C16078) are required to connect the 
DC power from Type 2A or Type 2 Power 
Modules to a SuperStack device when you need 
resilience. This cable allows you to hot-swap a 
module while maintaining the power supply to 
your network unit.

For more general information and warranty 
details for these products, please refer to 
SuperStack II Advanced RPS User Guide 
(DUA1607-0AAA0X). 

This guide is written for the installation 
engineer and the network administrator who 
manages and maintains the network. 

Technical Information

Physical

Length

0.92 metre (36 in)

Weight

1050 g (2.3 lb)

Safety Information

Please read the following safety 
information before installing the cable.

Installation of this cable should be carried out 
by qualified personnel only.

You must not attempt to connect the cable to 
any non-RPS power outlet. Damage will result 
to both the RPS and the SuperStack II product if 
you do.

L’Information de Sécurité

Veullez lire les instructions de sécurité 
suivantes avant d’installer le cable.

L’ installation du cable doit être faite 
uniquement par un personnel qualifé.

Vous ne devez en aucun cas connecter le cable 
à une entrée non RPS. Il en resulterait des 
dommages prejudiciales aux produits RPS et 
SuperStack II.

Sicherheitsinformationen

Lesen sie vor Einbau des Kabels die 
folgende Sicherheitsinformationen.

Der Ein- und Ausbau des Kabels sollte nur 
durch Fachpersonal erfolgen.

Verbinden sie das Kabel nur mit dem 
vorgesehenen RPS Ausgang. Bei nicht 
Beachtung wird der RPS und der SuperStack II 
beshädigt.

!

!

!