background image

 

Summary of Contents for EasyGate

Page 1: ......

Page 2: ...erference The minimum distance of the antenna and pacemakers should be 0 5 m Do not switch on EasyGate aboard of a plane Do not switch on EasyGate near petrol stations chemical facilities or sites where explosives are used Any mobile telephone use prohibition based on RF energy radiation applies to EasyGate too EasyGate may disturb the function of TV sets radio sets and PCs Warning EasyGate contai...

Page 3: ...sion 1 00D Upgrade The manufacturer continuously meets customer requirements by improving the firmware For the latest EasyGate processor firmware programming tool and User Manual see www 2n cz For a detailed description of the EasyGate firmware upgrade refer to the section devoted to the PC programming tool ...

Page 4: ...k Installation Guide mounting pattern 1 pc Software on a CD ROM 1 pc 3 Warranty certificate 1 pc Notes 1 The delivery includes an antenna to be connected directly to the EasyGate SMA connector An antenna with a cable can be ordered separately for places with a poor GSM signal 2 You will find the electronic format of the User Manual on a CD ROM 3 Enclosed software EasyGate PCManager EasyGate Driver...

Page 5: ...IN ENTERING VIA TELEPHONE LINE 8 4 3 AUTOMATIC PIN ENTERING 8 5 VOICE FUNCTION 9 5 1 OUTGOING CALL 9 5 2 INCOMING CALL 9 5 3 AUTOMATIC CALL BABYCALL 9 6 SMS SENDING INPUT 10 7 COM SERIAL INTERFACE 11 7 1 PROGRAMMING MONITORING 11 7 2 CSD PC PC DATA TRANSMISSION 11 7 3 FAX TRANSMISSION PC FAX 12 7 4 CSD OR HIGH SPEED GPRS DATA CONNECTION TO INTERNET 12 7 5 SMS SENDING AND RECEIVING 12 7 6 COMBINATI...

Page 6: ...ply adapter telephone cable PC serial cable SMS input connector CD ROM with software Solution for sites without telephone lines such as mountain chalets exhibitions conferences etc CLIP EasyGate is equipped with the FSK based CLIP feature so if a terminal capable of receiving the CLIP is used you know the caller s number Quick data connection EasyGate transmits data using the high speed GPRS conne...

Page 7: ...PCManager Place EasyGate out of range of sensitive devices and human bodies for electromagnetic interference reasons For the allowed range of operating temperatures refer to the Technical Parameters It is impossible to operate EasyGate on sites exposed to direct solar radiation or near heat sources EasyGate is designed for indoor use It may not be exposed to rain flowing water condensed moisture f...

Page 8: ...connector terminated cable not included in the delivery The antenna should be mounted vertically For antenna and cable parameters see the Technical Parameters 2 3 SIM Card Installation Make sure that the GSM provider s SIM card is compatible with the GSM network supported by your EasyGate version Open the SIM card holder on EasyGate s backside insert the SIM card and close it Select the required G...

Page 9: ...lay the CLI 2 6 Power Supply Connection EasyGate is fed with 10 16V DC Where a source other than the included power supply adapter is used the voltage range and polarity shown on the EasyGate power supply connector have to be maintained Do not activate the power supply until the antenna is connected to EasyGate to avoid the GSM module damage 2 7 SMS Sending Input Connection You have got a special ...

Page 10: ...a serial cable for PC connection It is a modem cable where all of the 9 pins are 1 1 interconnected in case you wanted to use another longer cable Make sure that a longer cable works properly to avoid errors at high transmission rates ...

Page 11: ...n progress 3 2 Telephone Line Tones 3 2 1 Operational Tones The GSM gateway sends tones to the telephone line to indicate the line status The tone frequency is 425 Hz Dial tone EasyGate is registered to GSM network and ready to receive dialing Ringing tone The called subscriber s telephone is ringing The GSM network transmits this tone Busy tone The busy tone is transmitted in any of the following...

Page 12: ...pon repeated wrong PIN entering attempts SIM card is blocked 3 2 2 Programming Mode Tones Tones confirming refusing the values entered are transmitted during telephone line based programming Each tone has a different melody Confirmation Confirms that the service password or parameter number entered is correct and has been accepted Refusal Incorrect parameter number Incorrect parameter value Transm...

Page 13: ...e in a while you have entered a wrong PIN and the SIM card is blocked Use the mobile phone to unblock the SIM card A correctly entered PIN is stored in EasyGate s memory as if you had programmed it using the PCManager The PIN will be entered automatically upon the next EasyGate power up 4 3 Automatic PIN Entering You need not enter the PIN upon power up if it is stored in EasyGate it is entered au...

Page 14: ...tablished 4 If the called subscriber is available you can hear the ringing tone If not you can hear the busy tone or any of the GSM provider s messages 5 When the called subscriber answers the call a call is established The Line LED is permanently on during the call 6 Hang up to terminate the call The Line LED goes off If the called subscriber is the first to hang up you can hear the busy tone and...

Page 15: ...y contact e g By activating this input electric input pin interconnection you send one SMS to one pre programmed telephone number Caution Do not use in life supporting or property protection applications because of the character of SMS service and EasyGate The manufacturer shall not be liable for health and property damage incurred as a result of SMS sending failure ...

Page 16: ...m is designed for EasyGate parameter programming It can read configuration data from the memory and store them in EasyGate Moreover all parameters can be saved in your PC file for backup or saving into another EasyGate system The EasyGate PCManager contains an easy monitoring tool too With this tool you can identify the GSM provider s name signal strength GSM module SIM and so on during EasyGate o...

Page 17: ...lephone number to be dialed DNS etc It is necessary for example to set the APN in modem extra settings in the GPRS mode Example at cgdcont 1 IP internet t mobile cz Caution GSM providers mostly specify the 99 number to be dialed for GPRS connection in their instructions SIEMENS GSM modules require the 99 1 format 7 4 1 CSD or GPRS Data Connection The maximum CSD transmission rate is 14400 bps GSM ...

Page 18: ...e transmitted EasyGate is a GPRS terminal of class B Once the call is terminated data transmission is recovered immediately 7 7 List of Supported AT Commands There are original files related to SIEMENS GSM modules in the PDF format on the EasyGate CD ROM Caution Since the GSM module is primarily used by the EasyGate central processor for voice calls use AT commands carefully You might misconfigure...

Page 19: ...p when you do not hear the confirmation tone 5 EasyGate shall remain in the programming mode until hang up 6 Enter the number of the parameter to be programmed and press a If the parameter number is correct you can hear the confirmation tone if not you get the refusal tone and can re enter the parameter number 7 When the parameter number is confirmed enter the allowed parameter value and press a I...

Page 20: ...m off and on again 8 2 1 Basic Programming Instructions 1 Run the PCManager and select the language for displaying texts on the right hand side 2 Click on the CD ROM icon for data handling on the left hand side 3 Load data from EasyGate if EasyGate is not in its special programming mode you are invited to switch EasyGate off and on again 4 Click on the programming table icon on the left hand side ...

Page 21: ...cluded in every new PCManager installation Upgrading procedure 1 Run the PCManager select the language for displaying texts on the right hand side 2 Click on the CD ROM icon for data handling on the left hand side 3 Click on the upgrade if EasyGate is not in its special programming mode you are invited to switch EasyGate off and on again 4 The upgrade takes place automatically Do not switch your P...

Page 22: ...rmation helps you find the optimum signal location the information is updated in 10s intervals The EasyGate line status standby outgoing call incoming call including telephone number The COM is locked during dialing and incoming call ringing so the PCManager reports COM blocking ...

Page 23: ...rts to establish connection when this timeout passes Setting options 1 15 s Setting step 1 s Default setting 5 s Tone after disconnection Function No If the remote subscriber hangs up first the EasyGate subscriber can hear the tone selected here Setting options Busy EasyGate transmits the busy tone upon call end Permanent EasyGate transmits the permanent tone upon call end Default setting Busy ton...

Page 24: ...is capable of receiving FSK according to ETSI standards Setting options Disable EasyGate does not transmit the CLI FSK during ringing EasyGate transmits the FSK based CLI according to the ETSI EN 300 659 standard transmission during ringing Tbd prepared for future use Default setting Do not transmit Replace character in CLI by Function No If this parameter is filled the character in the internatio...

Page 25: ... the dialed number matches this prefix The table can contain up to 20 different prefixes There may be exceptions to the rule a number may start with the same digits but has to be served in a different way Any table line that starts with the same prefix followed by one or more digits is considered an exception of the line with shorter prefix An example in the figure below shows how to bar all inter...

Page 26: ...g into a GSM network immediately after the last digit is dialed If the telephone number to be dialed is shorter a timeout is respected The 0 setting means that the function is disabled Setting options 0 3 15 Setting step 1 Default setting 0 End with Function No This parameter enables to establish the call when a is received The character is removed from the dialed number If a should be part of the...

Page 27: ...ing this timeout no SMS is sent even if the SMS input gets activated This prevents sending multiple SMS units in the case of repeated activation of the input Setting options 0 2550 s Setting step 10 s Default setting 0 s 8 3 4 GSM SIM Parameters GSM operator lock Function No Provider blocking is set by manufacturer in EasyGate If EasyGate is blocked to a GSM provider no other GSM provider s SIM ca...

Page 28: ...n for information only cannot be modified Must be used for communication with the manufacturer Firmware version Function No EasyGate firmware version EasyGate central processor program version The manufacturer can issue upgrades to extend functions To load new firmware into EasyGate use the Upgrade function Keep communicating with the manufacturer Serial number Function No EasyGate serial number f...

Page 29: ...ode SMS input initialization Function No 93 Initialization of all parameters for SMS sending upon SMS input activation Global initialization Function No 99 Initialization of all EasyGate parameters including the PIN and service password 8 3 7 Security Parameters PIN value Function No 40 Fill in the PIN value for automatic PIN entering upon EasyGate power up It is applied only if the SIM card is PI...

Page 30: ...a good GSM signal No tone can be heard after line off hook Check the telephone line connection EasyGate is not initialized properly upon start approx 10s after power up EasyGate is not supplied with power EasyGate keeps transmitting a tone during dialing not receiving the dialing Select the correct dialing type DTMF or pulse EasyGate does not communicate with PC Check the serial cable connection C...

Page 31: ...hone network GPRS General Packet Radio Service high speed data transmission for GSM networks HW Hardware an electronic device circuit board component etc in this context P A BX Private Automatic Branch Exchange PC Personal Computer based on the IBM PC standard PIN Personal Identification Number a SIM card securing password PUK Personal Unblocking Key a password used to unblock a blocked SIM card a...

Page 32: ... 12V consumption standby 60mA call data typ 200mA max 300mA Supply connector DC Jack 2 1mm Telephone Interface Interface type 2 wire analog FXS Telephone connector type RJ 12 6 2 Call impedance 600 Ω Loop voltage 24 V DC Loop current max 40 mA Loop resistance max 800 Ω Tone frequency 425 Hz Dialing type tone DTMF and pulse Ringing voltage 42 Vrms 50 Hz Calling line identification CLI during ringin...

Page 33: ...28 2004 2N TELEKOMUNIKACE a s ...

Reviews: