Chapter 37 Access Control
XGS1930 Series User’s Guide
313
Encryption protects the contents of the SNMP messages. When the contents of the SNMP messages are
encrypted, only the intended recipients can read them.
Supported MIBs
A MIB is a collection of managed objects that is organized according to hierarchy. The objects define
the attributes of the managed device, which includes the names, status, access rights, and data types.
Each object can be addressed through an object identifier (OID). An OID that begins with
“
1.3.6.1.4.1.890.1.15
” is a Zyxel-defined private MIB. Otherwise, it is a standard MIB OID.
MIBs let administrators collect statistics and monitor status and performance. The Switch uses both
standard public (RFC-defined) MIBs for standard functionality, and private MIBs that support additional
Switch functionality. Private MIBs contain Switch specific managed objects.
To view a list of standard MIBs supported by your Switch, see the product datasheet at www.zyxel.com
(
Support
>
Download Library
>
Datasheet
).
To get the private MIBs supported by your Switch, download (and unzip) the correct model MIB from
www.zyxel.com (
Support
>
Download Library
>
MIB File
).
SNMP Traps
The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the
SNMP traps by category.
Table 164 SNMP System Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
coldstart
coldStart
1.3.6.1.6.3.1.1.5.1
This trap is sent when the Switch is turned on.
warmstart
warmStart
1.3.6.1.6.3.1.1.5.2
This trap is sent when the Switch restarts.
poe
(For PoE models
only)
pethPsePortOnOffNotification
1.3.6.1.2.1.105.0.1
This trap is sent when the PoE port delivers
power or delivers no power to a PD.
pethMainPowerUsageOnNo
tification
1.3.6.1.2.1.105.0.2
This trap is sent when the usage power is
above the usage indication threshold.
pethMainPowerUsageOffNo
tification
1.3.6.1.2.1.105.0.3
This trap is sent when the usage power is
below the usage indication threshold.
Table 165 SNMP Interface Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
linkup
linkUp
1.3.6.1.6.3.1.1.5.4
This trap is sent when the Ethernet link is up.