9
7 Changing the System Password
The first thing your should do before anything else is to change the default system password by following the steps
below.
Step 1.
Enter 23 in the Main Menu to open
Menu 23 – System Password
as shown below.
Figure 6
Menu 23 – System Password
Step 2.
Enter your existing password and press the
[Enter] key
.
Step 3.
Enter your new system password and press the
[Enter] key
.
Step 4.
Re-type your new system password for confirmation and press the
[Enter] key
.
NOTE: As you type a password, the screen displays an (X) for each character you type.
7.1
Resetting the Prestige
You should already have downloaded the correct file from your nearest ZyXEL FTP server site. See the
Prestige 100L
User’s Guide
for more information on how to transfer the configuration file to your Prestige.
If you have forgotten your password or for some reason cannot access the SMT menu you need to reinstall the
configuration file. Uploading the configuration file replaces the current configuration file with the default
configuration file. You lost all configurations that you had before and the speed of the console port resets to the
default of
9600bps
with
8 data bit
,
no parity
,
1 stop bit
(8n1), and no
Flow Control
. The password resets to the
default value of 1234, also.
Turn off the Prestige and begin a Terminal session with the current console port settings. Turn on the Prestige again.
When you see the message "Press Any key to enter Debug Mode within 3 seconds", press any key to enter debug
mode.
Menu 23 - System Password
Old Password= ?
New Password= ?
Retype to confirm= ?
Press ENTER to Confirm or ESC to Cancel: