![ZyXEL Communications P-2302HWDL-P1 Support Notes Download Page 20](http://html1.mh-extra.com/html/zyxel-communications/p-2302hwdl-p1/p-2302hwdl-p1_support-notes_943989020.webp)
Prestige 2302 Support Notes
All contents copyright (c) 2005 ZyXEL Communications Corporation.
20
Generic
and
TCP/IP (and IPX)
filter rules are in different filter sets. You can only activate one type of filter
rules on the Prestige. The SMT automatically detects and prevents you from activating two filter types at the
same time. If you configure a Generic and a TCP/IP filter rule (as shown in the following figures) and try to
activate them at the same time, the
'Protocol and device filter rules cannot be active together'
error message
displays.
Menu 21.1.1:
Menu 21.1.1 - Generic Filter Rule
Filter #: 1,1
Filter Type= Generic Filter Rule
Active= Yes
Offset= 0
Length= 0
Mask= N/A
Value= N/A
More= No Log= None
Action Matched= Check Next Rule
Action Not Matched= Check Next Rule
Menu 21.1.2: