PROBLEM
POSSIBLE CAUSES AND REMEDIES
The
FDX/COL
(Ethernet) LED
is off
The RJ-45 port is operating in half-duplex mode or the
Ethernet link is down. See above for possible causes
and remedies.
The
LNK/ACT
(Fiber) LED is
off
Check the fiber cable connection between the media
converter and the remote device. Check that the
distance between them does not exceed limits for
single mode (MC100FX-SC30) or multi mode fiber
(MC100FX-SC2).
Check for faulty cables.
Check what duplex mode the remote device supports
and then set DIP switch 2 (off for full-duplex and on for
half-duplex).
If Link Loss Forwarding is enabled (DIP switch 3 is on),
then check if the Ethernet link is down (thereby forcing
the fiber link down).
The
FDX/COL
(Fiber) LED is
off
The fiber port is operating in half-duplex mode or the
fiber link is down. See above for possible causes and
remedies.