![ZyXEL Communications GS3700 Series Handbook Download Page 49](http://html1.mh-extra.com/html/zyxel-communications/gs3700-series/gs3700-series_handbook_944749049.webp)
49/215
www.zyxel.com
1.10.2 Test the Result
1
In
the
setting,
we
set
the
IP
range:
192.168.10.100-192.168.10.120
,
which
is allowed to access the
Switch by all protocol types, EXCEPT
HTTP.
Therefore, if we use
PC-1 (192.168.10.100) to access the Switch by
HTTP
, the Switch
will refuse the connection. If we try to access the web GUI by
HTTPS
(Enter the
https
://192.168.10.1), PC-1 can connect to the
Switch successfully.
2
The PC-2 (192.168.10.200) is not in the range which is allowed
to access the Switch. PC-2 cannot access or ping the switch’s
management IP address.
3
AdministratorPC can access the Switch by
all
service types
successfully.
Summary of Contents for GS3700 Series
Page 21: ...21 215 www zyxel com 2 Web GUI Go to Menu Management Maintenance Reboot System Custom Default...
Page 31: ...31 215 www zyxel com...
Page 35: ...35 215 www zyxel com 3 Click Save to save the configuration...
Page 54: ...54 215 www zyxel com 2 Enter Global field and check the TFTP server box...
Page 63: ...63 215 www zyxel com Without Class ID...
Page 79: ...79 215 www zyxel com 2 2 4 Test the Result 1 PC 1 can ping PC 2 successfully...
Page 101: ...101 215 www zyxel com 8 Finally connect the link between Switch 2 and Switch 3...
Page 153: ...153 215 www zyxel com...
Page 192: ...192 215 www zyxel com...
Page 199: ...199 215 www zyxel com...